WLD sensing cable Type B 2 m for leak detection, thin design, without connecting cable - HW group 600912
A thin 2 m Type B water sensing cable that detects conductive liquids along its whole length. It extends an existing WLD zone and ships without a connecting cable. Typically added as a short extra section at A/C units, CDUs or condensate lines.
- Specialist dealer since 2009
- Invoice payment for regular customers
- Worldwide shipping
- Technical questions clarified with the manufacturer
Description
An existing WLD zone often needs just a short extra section, for example under a newly installed cooling unit. The Type B sensing cable adds 2 m of coverage and reports a few drops at any point. It joins the zone through the same 2-pin locking connector used by Type A.
Benefits
- Detection along the full length: a few drops of conductive liquid anywhere on the 2 m trigger an alarm.
- Thinner than Type A: the smaller diameter dries faster, and the cable can be cleaned, dried and reused.
- Tolerant installation: no bend radius and no twist limit, stepping on or pressing the cable causes no false alarm, and it can run under door thresholds.
- Mix with Type A: both types can share one zone, up to 185 m per zone with extension cables.
Applications
- Extra section under A/C and cooling units in server rooms
- Liquid cooling with CDUs and quick disconnects
- Condensate lines and chillers
- Boiler rooms around pumps and valves
Compatibility
- Extends a WLD zone connected via AB connecting cable to HW group devices with a WLD zone input
- Can be combined with WLD sensing cable Type A in the same zone
- Ready-to-connect sets with connecting cable: 600918, 600919, 600920, 600921
Technical data
| Measured variable | Leakage of conductive liquids, resistive principle |
|---|---|
| Range | 0-1 (leak yes/no) |
| Cable type | WLD sensing cable Type B |
| Length | 2 m |
| Connector | 2-pin, locking |
| Max. zone length | 185 m |
| System reaction time | 1-5 minutes from first drops to alarm |
| Galvanic isolation | No |
| Operating conditions | 0 to +60 °C, 0-100 % RH |
| Storage conditions | -30 to +60 °C, 5-95 % RH |
| Installation | Floor, wall |
| Warranty | 24 months |
| Manufacturer part number | 600912 |
| Weight | 0.024000 |
| Manufacturer | HW group |
| Hersteller-Nr | 600912 |
| Zolltarifnummer | 90269000 |
| GPSR Herstellerdaten | HW group s.r.o., Rumunská 26, CZ-120 00 Praha 2, www.hw-group.com |
| Artikelzustand | New |
| Artikel-Authentizität | Original product |
| Country of Manufacture | Czechia |
| Warranty | 2 years |
Scope of delivery
- 1 x WLD sensing cable Type B, 2 m
- Not included: WLD connecting cable AB
Downloads
Accessories
Water leak detector WLD2 PoE, 4 zones up to 185 m each, LAN and WiFi, SNMP, plain unit - HW group 600717
Item HWG-600717Water leak detector WLD-ECHO, 2 WLD zones, audible alarm, relay output, plain unit without accessories - HW group 600938
Item HWG-600938Rack monitoring system Perseus Monitoring 150, 1U, 8 sensor ports, 16 DI, 4 relays, PoE, plain unit - HW group 600845
Item HWG-600845Connecting cable WLD-Connecting cable AB, 2 m, for Type A and B sensing cables, with terminator - HW group 600924
Item HWG-600924Cover strip WLD-Cover Strip B 30, 5 m, self-adhesive, 30 mm wide, for Type B sensing cable - HW group 600917
Item HWG-600917Perforated tape WLD-Poro Tape, 5 m, white, for fixing WLD sensing cables to floors and walls - HW group 600910
Item HWG-600910Extension cable WLD-Extension cable AB, 5 m, non-sensing, for Type A and B sensing cables - HW group 600925
Item HWG-600925ESD version
WLD sensing cable Type B 5 m for leak detection, thin design, without connecting cable - HW group 600913
Item HWG-600913Questions about this item
Any other question?
Send us the item number and your question. We clarify technical details directly with the manufacturer and usually reply on the next working day. Ask a question