Labelling and Plant Documentation

Pipe Marking to DIN 2403

Pipe marking to DIN 2403 assigns every line to the medium it carries. The carrier names the medium in plain text, an arrow shows the flow direction and the colour assigns the medium to its group, aqueous media in green and air in grey. In a data centre the flow and return of the water-glycol loop, chilled water, condensate and compressed air run close together, usually in redundant pairs and in identical pipe sizes. Only the marking shows at a closed valve which of the parallel circuits has actually been isolated.

Markers belong at branches, upstream and downstream of valves, at wall and ceiling penetrations and wherever a line becomes visible again after a concealed run, always facing the operator. Run number, the flow or return designation and the note on the glycol mixture belong on the same carrier. No products are listed in this category yet; the range is being built up.

  • Net prices plus VAT
We can't find products matching the selection.

Buying guide

How to choose Pipe Marking to DIN 2403

What matters when choosing: properties, comparison and typical applications.

Technical Benefits - Pipe Marking to DIN 2403

⚡ Medium in plain text - the name of the medium is on the pipe, not only in the drawing
↕ Arrow for flow direction - flow and return can be told apart at the component
⚙ Colour group by medium - the assignment works from a distance and under plant lighting
✓ Repetition at nodes - branch, valve and penetration each carry the statement
⚠ Additional detail for redundancy - run A and run B are not confused
↻ Exchangeable carrier - modifications or a change of medium can be updated

Structure of the Marking

Information on a pipe marker

ItemContentValue when working on the circuit
Mediumname in plain text, such as cooling water or condensateno confusion between lines of the same size
Flow directionarrow pointing with the flowflow and return can be assigned
Colour groupcolour according to the group of the mediumfast orientation in the service route
Run and circuit numbercircuit identifier, A or B where redundantthe correct isolating device is chosen
Additional and warning noteglycol mixture, hot surface, plant pressureprotective measures before opening

Typical Applications

  • Manifolds and headers in the plant room
  • Pump set, filters and isolating valves of the cooling loop
  • Risers and penetrations between floors
  • Connection of cooling manifold and rack in the white space
  • Free cooler, dry cooler and make-up line
  • Compressed air and condensate lines sharing the same route