Temperature Measurement

Measurement, Monitoring and Leak Detection

Medium temperature is the leading variable in a data centre. Supply temperature sets how much heat a rack can absorb, the spread between supply and return shows how much of it is actually carried away. The category holds 69 items from Riegler, Wika and Fluidics equipment: Pt100 and Pt1000 resistance thermometers plus bimetal thermometers for local indication. The miniature TR33 with M12x1 connector and the compact TR36 are available with insertion lengths of 50, 100, 150 and 200 mm.

The Pt1000 versions output 4-20 mA and connect straight to the building management system without an intermediate transmitter. Pt100 probes with IP 69 protection and a G 1/4 or G 1/2 process connection cover -40 to +85 °C, vertical bimetal thermometers 0 to +120 °C in accuracy class 1. Wetted parts in 1.4571 and 1.4301 are unrestricted in a water-glycol loop. Where a probe has to be replaced while the plant runs, it belongs in a thermowell rather than directly in the medium.

🌡 Pt100 and Pt1000 - standard characteristics, interchangeable between controller and BMS
⚙ 4-20 mA on TR33 and TR36 - two-wire loop without a separate transmitter in the cabinet
↕ insertion lengths 50 to 200 mm - matched to pipe sizes from branch line to header
📈 -40 to +120 °C - chilled water, free cooling and warm return in one series
✓ IP 69 protection - unaffected by condensate at the head and by wash-down cleaning
🔧 1.4571 and 1.4301 - stainless wetted parts, no reservation for glycol mixtures

Probe designs compared

DesignElementSignalInsertion lengthConnection
Miniature thermometer TR33Pt10004-20 mA50, 100, 150, 200 mmM12x1 plug
Compact thermometer TR36Pt10004-20 mA50, 100, 150, 200 mmterminal head
Resistance thermometer IP 69Pt100resistance outputup to 150 mmG 1/4 or G 1/2, 1.4571
Bimetal thermometer, verticalbimetal coillocal indication100 mm1.4301, class 1

  • supply and return temperature at the cooling manifold and the CDU
  • spread across the heat exchanger between primary and secondary loop
  • free cooling threshold at the dry cooler based on return temperature
  • frost protection monitoring in the outdoor section of the glycol loop
  • local indication at pump set and buffer tank without auxiliary power
View as Grid view List view

Items 1-24 of 129

Set Descending Direction
per page
  1. Temperature and humidity sensor 1WR-HTemp B1, -30 to +70 °C, 0-100 % RH, 40 x 40 mm room box, 3 m cable - HW group 600911
    €128.30