Data Center

Insulation, Condensate and Leak Protection

In a data centre chilled-water circuit the supply temperature is often below the dew point of the room air. Moisture then forms on pipework, manifolds, valves and fittings and drips onto cable trays, raised floors and electronics. Insulation here is not thermal economy alone, it protects the installation: it keeps the surface temperature above the dew point and keeps water vapour away from the pipe wall. Collection trays, drainage channels and absorbents cover the area below liquid-cooled racks, CDUs and pump sets against escaping water-glycol mixture.

For the time being this section only describes what these components do in the cooling circuit. None of the four subcategories currently holds a single article, the range is still being built up, and three of the four branches are not yet live. The structure stays visible so that the cooling circuit is shown in full and the gap remains obvious. Insulation thicknesses, tray sizes and absorbents are quoted case by case.

  • 1 subcategory
  • Net prices plus VAT
We can't find products matching the selection.

Buying guide

How to choose Insulation, Condensate and Leak Protection

What matters when choosing: properties, comparison and typical applications.

Why insulation is installation protection in an IT circuit

💧 Dew point, not heat loss - with a supply below the room dew point, condensate forms on even short uninsulated sections
⚡ Water above live equipment - in a data centre dripping condensate reaches cable trays, distribution boards and racks
⚙ Valves and fittings are the weak point - valves, flanges, unions and metal clamps stay exposed without fitted shells and sweat
⚠ Corrosion under insulation - moisture that has entered no longer dries out and attacks the pipe wall from outside
↕ A second line below the rack - trays and channels catch what insulation cannot prevent and lead it away under control
✓ Materials for the water-glycol circuit - stainless steel, PE, PP, PVC and PTFE are unrestricted, galvanised steel and aluminium do not belong in this circuit

System comparison & materials

The four building blocks of condensate and leak protection

Building blockFunction in the circuitCommon materialsTypical location
Pipe insulation and insulating shellsKeeps the pipe surface above the dew point of the room airElastomeric foam, PE foam, PUR/PIR shellsSupply and return lines, manifolds, risers
Condensate protection and vapour barriersStops water vapour migrating through the insulation to the pipeFactory facings, barrier membranes, adhesives and tapesSeams, butt joints, terminations at valves and clamps
Spill trays and drainage channelsCatches escaping water-glycol mixture and drains it awayPE, PP, PVC, stainless steelBelow CDUs, pump sets, manifolds and rack connections
Absorbents and floor protectionPicks up residual liquid and keeps the raised floor walkablePP absorbent fleece, mineral granulate, celluloseRaised floor, service aisles, transfer points

Typical applications

  • Chilled-water distribution in the raised floor and in riser shafts
  • Connection of CDUs and rear-door heat exchangers to the building circuit
  • Direct liquid cooling at the rack with a supply below the room dew point
  • Dry-cooler and free-cooling lines carrying a water-glycol mixture
  • Transfer points between building services and the IT circuit
  • Maintenance and retrofit work where circuits are opened, drained and refilled