Coolants and Loop Chemistry

Data Center

Coolants and loop chemistry cover everything that circulates in the liquid loop of a data centre or keeps it serviceable: the heat transfer fluid itself, its inhibitor package, agents against microbial growth, cleaners for commissioning and the instruments used to assess the condition of the loop. The common approach in an IT loop is a mixture of deionised water and propylene glycol at a glycol content of around 25 percent. It protects outdoor piping and dry coolers against freezing without loading heat transfer as heavily as higher concentrations do.

Two things decide how long a fill lasts: the inhibitor package that maintains the passive layers of the installed materials, and regular sampling, which reveals inhibitor depletion, pH drift or early microbial growth before damage occurs. This section is currently being built up: the subcategories describe the function each group has in the cooling loop, articles are not listed yet. On material compatibility and miscibility we can advise already now.

Coolants and Glycol ConcentratesWater-glycol mixtures and concentrates for the IT loop
Corrosion InhibitorsProtecting passive layers where mixed materials meet
Biocides and System CleanersAgainst biofilm and residues from assembly and operation
Sampling, Test Strips, RefractometersChecking glycol content, pH and germ count in service
Thermal Interface Materials for Cold PlatesPastes, pads and gap fillers between chip and cold plate

⚡ Propylene glycol at around 25 percent - the common approach in an IT loop, freeze protection without needless loss of heat transfer
✓ Material rule of the loop - stainless steel, PVDF, PP, PE, PTFE, POM and PVC without restriction, galvanised steel and aluminium not at all
⚙ Inhibitor package rather than single additive - a matched formulation keeps the passive layers intact across the whole fill
↕ Sampling on a fixed schedule - pH, glycol content and germ count show the condition before the damage occurs
⌛ Range under construction - the subcategories describe the function in the loop, articles will follow

Materials in the water-glycol loop of a data centre - suitability and limits

MaterialSuitability in the IT loopNote
Stainless steelunrestrictedstandard for pipe, valve and fitting
PVDF, PP, PE, PTFEunrestrictedhose, fitting and housing parts
POM, PVCunrestrictedmoulded parts and side stream components
Brass, red brass, bronze, copperonly with single-material pairingavoid contact with other metals in the same loop
Galvanised steelnot permittedzinc dissolves in a glycol loop and enters the fill
Aluminiumnot permittedcannot be controlled long term in a mixed loop with stainless steel and copper alloys

  • Initial fill of new direct-to-chip cooling loops
  • Topping up and reconcentrating existing fills
  • Flushing and cleaning before commissioning
  • Recurring condition checks during operation
  • Dry coolers and outdoor piping exposed to frost