Data Center

The Data Center branch groups the components that carry water and water-glycol from the facility loop to the chip. The path starts in the Facility Water System (FWS) with dry cooler, pump and distribution, runs through the Coolant Distribution Unit (CDU) that hydraulically separates facility side and IT side, and ends in the IT Cooling Loop (TCS) at cold plates, rear-door heat exchangers or immersion tanks. Every disconnect, valve and fitting along that path is filed here: around 45,000 items in 15 sections, from quick disconnects through strainers and flow switches to plate heat exchangers.

The tree is organised by function in the loop, not by manufacturer and not by material. A dry-break disconnect belongs under Couplings and Disconnects, whether it is made by Nitto Kohki, Cejn or Stauff. The three loop-level sections Facility Water System (FWS), Coolant Distribution (CDU) and IT Cooling Loop (TCS) are still being built up: for now they describe what each level does, the product range follows. The same applies to coolants, insulation and labelling.

Categories

All areas for Data Center

Pick an area to see its products and filters.

Facility Water System (FWS)Dry coolers, pumps and facility-side distribution, range being builtView →
Coolant Distribution (CDU)Hydraulic separation of facility and IT loop, range being builtView →
IT Cooling Loop (TCS)Rack and chip level loop with cold plate and rear door, being builtView →
Couplings and Disconnects
Couplings and DisconnectsDry-break quick disconnects in stainless steel and brass1,896 items →
Shut-Off, Control and Safety Valves
Shut-Off, Control and Safety ValvesBall valves, control and safety valves for water-glycol loops5,958 items →
Piping and Connection Technology
Piping and Connection TechnologyPipe, hose, fittings and adapters from manifold to rack12,035 items →
Filling, Venting, Draining
Filling, Venting, DrainingFill, vent and drain fittings for commissioning and service73 items →
Measurement, Monitoring and Leak Detection
Measurement, Monitoring and Leak DetectionGauges, thermometers, flow switches and leak monitoring2,904 items →
Filtration and Loop Cleaning
Filtration and Loop CleaningStrainers, filter elements and flushing accessories for the loop387 items →
Sealing Technology
Sealing TechnologyO-rings, flat gaskets and seal kits, material chosen by medium421 items →
Coolants and Loop ChemistryWater-glycol mixtures, inhibitors and test kits, range being builtView →
Mounting and Cable Management
Mounting and Cable ManagementPipe clamps, rails and brackets in plastic and stainless steel8,240 items →
Insulation, Condensate and Leak ProtectionInsulation against condensate plus drip and leak protection, being builtView →
Labelling and Plant DocumentationLine marking, plates and plant documentation, range being builtView →
Tools, Assembly and Test Equipment
Tools, Assembly and Test EquipmentAssembly tools and test equipment for couplings and fittings22 items →

Advantages

Technical benefits

The key technical properties at a glance.

⚡ 45,004 items in 15 sections - from the facility loop to the disconnect next to the chip, from one source
⚙ Structured by function - you search by the job in the loop, not by brand or material
✓ Materials for the IT loop - stainless steel, PVDF, PP, PE, PTFE, POM and PVC are usable without restriction
⚠ Copper alloys only in matched pairs - brass, gunmetal, bronze and copper only with single-material pairing, galvanised steel and aluminium not at all
↕ Disconnects for service under load - dry-break quick disconnects in stainless steel and brass, for example Nitto Kohki Zero Spill and Cejn ultraFLOW
◆ Brands in this branch - Riegler, Stauff, Wika, Sang-A, Nitto Kohki, Cejn, Hydac, KTR and Bosch Rexroth

In detail

System comparison & product overview

The key data in table form.

The three loops compared - facility water system, coolant distribution and IT cooling loop

CriterionFacility Water System (FWS)Coolant Distribution (CDU)IT Cooling Loop (TCS)
FunctionReject waste heat from the building to dry coolers and ambientHydraulic separation of both loops, control of pressure and temperaturePick up heat directly at the rack and at the component
Mediumwater or water-glycol on the facility sidefacility water on the primary side, treated coolant on the secondary sidetreated water-glycol mixture in a closed loop
Typical componentspumps, dry coolers, shut-off valves, strainersplate heat exchangers, control valves, instrumentation, filtrationmanifolds, hoses, dry-break couplings, seals
Materialssteel and stainless steel, common on the facility sidestainless steel and plastics on the secondary sidestainless steel, PVDF, PP, PE, PTFE, POM, PVC; no aluminium, no galvanised steel
Status in the cataloguesection being built upsection being built upsection being built up
Components already listed undervalves, piping, filtrationmeasurement and monitoring, valves, filtrationcouplings and disconnects, sealing technology, piping

Overview

Typical applications

Background and details for this range.

  • Direct-to-chip cooling with cold plates in AI and HPC racks
  • Rear-door heat exchangers and rack-level air handling
  • Coolant distribution between facility loop and IT loop, primary and secondary side
  • Conversion of existing air-cooled racks to liquid cooling
  • First fill, flushing and commissioning of new cooling loops
  • Hot-swapping modules through dry-break disconnects
  • Test benches and laboratory rigs for cooling components