Rack monitoring system Perseus Monitoring 150, 1U, 8 sensor ports, 16 DI, 4 relays, PoE, plain unit - HW group 600845
Perseus Monitoring 150 monitors a server cabinet or an entire server room from a single 19-inch rack unit. It offers 8 RJ11 ports for 1-Wire UNI sensors, 16 digital inputs, 4 relays, a WLD zone and RS-485 for Modbus/RTU, powered by PoE, 48 V DC or 9-30 V DC. Plain unit without power adapter or 19-inch mounting kit.
- Specialist dealer since 2009
- Invoice payment for regular customers
- Worldwide shipping
- Technical questions clarified with the manufacturer
Description
Data centers need temperature, doors, leaks and third-party equipment such as UPS or air conditioning reported in one place, without giving up much rack space. Perseus Monitoring 150 fits 8 sensor ports, 16 digital inputs and 4 relays into 1U and handles up to 100 meters with 1000 variables.
Benefits
- High port density in 1U: 8 RJ11 ports for 1-Wire UNI sensors and 16 digital inputs for door contacts, smoke detectors or fan failure signals.
- Simple power in the rack: PoE or 48 V DC at 250 mA, alternatively 9-30 V DC.
- Third-party integration: RS-485 with Modbus/RTU reads energy meters, UPS or air conditioning units from other vendors.
- Local reaction: 4 relay outputs (max. 50 V, 1000 mA) control cooling, ventilation or doors based on readings.
- Leak detection: 1 WLD zone for water sensing cable, for example under the raised floor or along coolant distribution.
- DCIM and BMS integration via SNMP v1 and v3, Modbus/TCP, MQTT, BACnet/TCP and XML.
Applications
- Single racks and rack rows in data centers, cold and hot aisles
- Server rooms and technical rooms with many measuring points
- Leak monitoring under raised floors and around CDUs and quick disconnects in liquid cooling
- Telecommunication installations and remote infrastructure sites
- Site data concentrator for sensors and meters
Compatibility
- HW group 1-Wire UNI sensors on the RJ11 ports
- HW group WLD sensing cables on the WLD zone
- Meters API: HWg devices such as STE2 R2 via XML, plus devices using SNMP, Modbus/TCP, MQTT or Modbus/RTU
- Portal based on SensDesk technology and the HWg Monitor app for Android and iOS
Technical data
| Network | Ethernet RJ45, 10/100 Mbit/s, DHCP, IPv6 |
|---|---|
| Protocols | HTTP, HTTPS, SNMP v1 and v3, SNMP trap, SMTP with TLS, SNTP, XML, MQTT, Modbus/TCP, BACnet/TCP |
| Sensor ports | 8 x RJ11 for 1-Wire UNI sensors |
| RS-485 | 1 x terminal block, Modbus/RTU |
| Digital inputs | 16 x dry contact, with counters |
| Water leak detection | 1 x WLD zone |
| Relay outputs | 4 x relay, max. 50 V, 1000 mA |
| Capacity | up to 100 meters, 1000 variables, 32 MB data logger |
| Alerting | Email, SNMP trap, SMS and calls via external SMS gateway, up to 100 recipients each |
| Security | RADIUS (IEEE 802.1X), admin and user accounts, HTTPS with custom certificate |
| Power supply | 9-30 V DC via barrel jack (2.1/5.5 mm) or terminal block, 48 V DC via terminal block, PoE via RJ45 |
| Consumption | 500 mA at 9-30 V DC, 250 mA at 48 V DC and PoE |
| Operating conditions | -30 to +85 °C, 5-95 % RH |
| Dimensions and weight | 300 x 145 x 38 mm (W x H x D), 1120 g, 1U |
| Housing and mounting | Metal, 19-inch rack or table |
| Ingress protection | IP40 |
| Warranty | 24 months |
| Manufacturer part number | 600845 |
| Weight | 1.057 kg |
| Manufacturer | HW group |
| Hersteller-Nr | 600845 |
| Zolltarifnummer | 85176200 |
| GPSR Herstellerdaten | HW group s.r.o., Rumunská 26, CZ-120 00 Praha 2, www.hw-group.com |
| Artikelzustand | New |
| Artikel-Authentizität | Original product |
| Country of Manufacture | Czechia |
| Interface | Digital I/O, Ethernet, RS-485, 1-Wire |
| Protection rating | IP40 |
Scope of delivery
- Perseus Monitoring 150 plain unit
- Not included: power adapter and 19-inch mounting kit
Downloads
User Manual
Declaration of Conformity
Accessories
Rack temperature and humidity sensor 1WR-HTemp Rack19 2p, -10 to +80 °C, 0-100 % RH, 1U, 2x RJ11 - HW group 600889
Item HWG-600889Rack temperature sensor 1WR-Temp Rack19 2p, -10 to +80 °C, 1U, 2x RJ11 for daisy-chaining - HW group 600888
Item HWG-600888Door contact MK4 for digital input, dry contact, 3 m cable, IP40 - HW group 600371
Item HWG-600371Water flood detector 1W-UNI 3m, spot detection with 4 contact pins, IP67, 3 m cable, RJ11 - HW group 600579
Item HWG-600579Power presence detector Power Detector 110-230 V AC, EU plug Type C, relay output for DI - HW group 600667
Item HWG-600667Optical smoke detector FDR26, 12 V DC, relay output for digital input, IP40 - HW group 600427
Item HWG-600427Wall plug power adapter 12 V DC, 1.5 A, international with EU, UK, US plugs - HW group 600620
Item HWG-600620Show 3 more items
WLD sensing cable Type B set 2+2 m, 2 m sensing cable with 2 m connecting cable AB, ready to connect - HW group 600918
Item HWG-600918Connecting cable WLD-Connecting cable AB, 2 m, for Type A and B sensing cables, with terminator - HW group 600924
Item HWG-600924ESD version
Rack monitoring system Perseus Monitoring 150 Tset, temperature starter set with adapter and 1WR-Temp - HW group 600864
Item HWG-600864Rack monitoring set Perseus Monitoring 150 Rack Tset with 19-inch brackets, WLD cable and door contact - HW group 600869
Item HWG-600869Rack monitoring system Perseus Monitoring 155 with LTE backup, 8 sensor ports, 16 DI, PoE, plain unit - HW group 600846
Item HWG-600846Questions about this item
Any other question?
Send us the item number and your question. We clarify technical details directly with the manufacturer and usually reply on the next working day. Ask a question