Compressed Air Preparation
Filter Regulator
Filter regulators combine a filter and a pressure regulator in one housing: they separate particles and condensate and keep the outlet pressure constant. The Festo MS series comes in sizes MS4, MS6, MS9 and MS12, complemented by compact PCRP filter regulators.
Available are filter grades of 5 µm and 40 µm, regulating ranges up to 7 bar or up to 12 bar, and condensate drains with manual rotary, manual push or fully automatic operation. Ports G 1/8 to G 1 and NPT 1/8 to NPT 1/2, with or without pressure gauge.
Narrow down the selection by filter grade, regulating range, condensate drain or port.
- 425 items
- 1 manufacturer
- Net prices plus VAT
Buying guide
How to choose Filter Regulator
What matters when choosing: properties, comparison and typical applications.
Selection criteria
| Criterion | Options | What to look for |
|---|---|---|
| Filter grade | 40 µm, 5 µm | 40 µm is sufficient for most pneumatic drives. Choose 5 µm for more sensitive valves and consumers. |
| Regulating range | 0.3 to 7 bar, 0.5 to 12 bar | Choose the smallest range that covers your working pressure, it allows finer adjustment. |
| Condensate drain | manual rotary, manual push, fully automatic | With a lot of condensate or a hard-to-reach location the fully automatic drain makes sense. |
| Size and port | MS4, MS6, MS9, MS12, PCRP; G 1/8 to G 1, NPT 1/8 to NPT 1/2 | The size determines the possible flow, the port the connecting line. |
Frequently asked questions
- Filter regulator or separate filter and regulator?
- The filter regulator takes less space and needs only one connection. Separate units make sense if you combine filter stages or want to replace filter and regulator independently.
- Which filter grade do I need?
- 40 µm is the usual grade for cylinders and valves. 5 µm is available for more sensitive consumers. Finer grades down to 0.01 µm are offered by the separate fine filters.
- What does the fully automatic condensate drain do?
- It empties the filter bowl automatically as soon as condensate collects. This prevents water from entering the system if manual draining is forgotten.