1-Wire UNI USB calibrator for sensor converters, scaling, units and 8-point calibration - HW group 600535
A USB cable for setting up and calibrating 1-Wire UNI sensors. It lets you define output scale, calibration points, unit and exponent inside the converter, so the sensor reports the real quantity such as pressure or tank level. Supports 8-point conversion charts, or 3 points on older sensors.
- Specialist dealer since 2009
- Invoice payment for regular customers
- Worldwide shipping
- Technical questions clarified with the manufacturer
Description
An industrial probe with a current or voltage output only gives you mA or V, while what you need is bar, litres or ppm. The 1-Wire UNI USB calibrator writes a conversion chart with up to 8 points straight into the converter.
Benefits
- Real readings: unit, exponent and output scale are stored in the sensor, and the monitoring unit shows the actual value.
- Accurate charts: 8-point calibration tables, 3 points on older sensors.
- Any conversion: any conversion chart can be loaded directly into 1-Wire UNI converters.
- Small and USB-powered: 67 x 16 x 16 mm, 8 g, 5 V at 40 mA.
Applications
- Setting up current and voltage converters for Poseidon units
- Displaying pressure, tank level or gas concentration from industrial probes
- Adapting pressure transmitters in the coolant loop of a liquid cooling system with CDU
- Readjusting converters in plant rooms and distribution boards
Compatibility
- 1-Wire UNI converters with calibration table, for example Sensor 0-20mA 1W-UNI (600566) and Sensor 60V 1W-UNI v2 (600534)
- Poseidon units with 1-Wire UNI bus as the target system for calibrated sensors
Technical data
| Type | USB calibrator for 1-Wire UNI sensors |
|---|---|
| Functions | Output scale, calibration points, unit, exponent |
| Calibration chart | Up to 8 points, 3 points on older sensors |
| Interfaces | USB, 1-Wire UNI |
| Power supply | 5 V |
| Consumption | 40 mA |
| Operating conditions | -10 to +80 °C, 0 to 100 % RH |
| Storage conditions | -30 to +60 °C, 5 to 95 % RH |
| Housing | Plastic |
| Dimensions (W x H x D) | 67 x 16 x 16 mm |
| Weight | 8 g |
| Warranty | 24 months |
| Manufacturer part number | 600535 |
| Weight | 0.010000 |
| Manufacturer | HW group |
| Hersteller-Nr | 600535 |
| Zolltarifnummer | 90309000 |
| GPSR Herstellerdaten | HW group s.r.o., Rumunská 26, CZ-120 00 Praha 2, www.hw-group.com |
| Artikelzustand | New |
| Artikel-Authentizität | Original product |
| Country of Manufacture | Czechia |
| Warranty | 2 years |
| Housing material | Plastic |
| Interface | USB, 1-Wire |
Scope of delivery
- 1 x 1-Wire UNI USB calibrator (USB cable)
- Not included: sensors and converters
Downloads
Datasheet
User Manual
Declaration of Conformity
Accessories
Rack monitoring system Perseus Monitoring 150, 1U, 8 sensor ports, 16 DI, 4 relays, PoE, plain unit - HW group 600845
Item HWG-600845Remote monitoring unit Perseus Monitoring 140, 4 sensor ports, 4 DI, 2 relays, WLD, plain unit - HW group 600843
Item HWG-600843LAN/WiFi thermometer STE2 R2 with 3 m temperature sensor and power adapter, 2 RJ11 sensor ports, 2 DI, PoE - HW group 600753
Item HWG-600753Sensor calibration with accredited laboratory certificate, 1 physical quantity, 3 calibration points - HW group 600575
Item HWG-600575Questions about this item
Any other question?
Send us the item number and your question. We clarify technical details directly with the manufacturer and usually reply on the next working day. Ask a question