Images are examples, some edited with AI. The technical data are authoritative. AI notice
Pt100 low temp set Temp-1W-UNI Pt100 Frost, -190 to +150 °C, probe on 2 m PTFE cable plus converter - HW group 600616
Low temperature set of a Pt100 probe (Pt100/B, -190 to +150 °C, 2 m PTFE cable) and the Converter 2xPt100 1W-UNI. The converter runs on a 1-Wire UNI RJ11 port and accepts a second Pt100 or Pt1000 probe. Made for deep freezing, cryogenic storage and refrigeration plants.
- Specialist dealer since 2009
- Invoice payment for regular customers
- Worldwide shipping
- Technical questions clarified with the manufacturer
Description
At very low temperatures, standard probes and cables give up. This set pairs a Pt100/B cryogenic probe on PTFE cable, rated for -190 to +150 °C, with the 1-Wire UNI converter that passes readings on to Poseidon2 or Ares units.
Benefits
- Built for the cold: -190 to +150 °C range, PTFE-sheathed cable.
- Accurate: ±0.3 °C from -50 to +150 °C and ±0.6 °C from -190 to -50 °C.
- Two measuring points: add a second Pt100 or Pt1000 probe to the converter.
- Bus powered and chainable: 5 V via RJ11 at 20 mA, more sensors can be daisy-chained.
- Alerts via the host unit: Poseidon2 sends e-mail or SMS when a value leaves its SafeRange.
Applications
- Deep freezers and cryogenic storage
- Refrigeration plants and cooling circuits running at very low temperatures
- Drug and sample storage with e-mail or SMS alerting
Compatibility
- Works with Poseidon2 (e.g. 3266) over LAN and Ares 12 over GSM according to the manufacturer
- Not usable with Poseidon1, HWg-STE, HWg-STE PoE or HWg-STE plus
- The converter counts as two sensors on a Poseidon2 unit
Technical data
| Measured value | Temperature |
|---|---|
| Probe measuring range | -190 to +150 °C |
| Accuracy | ±0.3 °C from -50 to +150 °C, ±0.6 °C from -190 to -50 °C |
| Resolution | 0.1 °C |
| Sensing element | Pt100/B |
| Probe cable | 2 m, PTFE-sheathed |
| Values from converter | 2 (second probe optional) |
| Calibration points | 8 |
| Interface | 1-Wire UNI, RJ11 |
| Power supply | 5 V via RJ11 (1-Wire bus) |
| Consumption | 20 mA |
| Galvanic isolation | No |
| Converter operating conditions | -30 to +85 °C, 0 to 100 % RH |
| Storage conditions | -30 to +60 °C, 5 to 95 % RH |
| Converter dimensions (W x H x D) | 79 x 68 x 30 mm |
| Weight | 197 g |
| Converter protection | IP23 |
| Warranty | 24 months |
| Manufacturer part number | 600616 |
| Weight | 0.250000 |
| Manufacturer | HW group |
| Hersteller-Nr | 600616 |
| Zolltarifnummer | 90259090 |
| GPSR Herstellerdaten | HW group s.r.o., Rumunská 26, CZ-120 00 Praha 2, www.hw-group.com |
| Artikelzustand | New |
| Artikel-Authentizität | Original product |
| Country of Manufacture | Czechia |
| Warranty | 2 years |
| Interface | 1-Wire |
| Protection rating | IP23 |
Scope of delivery
- Pt100/B cryogenic probe with 2 m PTFE cable
- Converter 2xPt100 1W-UNI with RJ11 connection
- Not included: second Pt100 or Pt1000 probe
Downloads
Accessories
Rack monitoring system Perseus Monitoring 150, 1U, 8 sensor ports, 16 DI, 4 relays, PoE, plain unit - HW group 600845
Item HWG-600845Remote monitoring unit Perseus Monitoring 140, 4 sensor ports, 4 DI, 2 relays, WLD, plain unit - HW group 600843
Item HWG-600843LAN/WiFi thermometer STE2 R2 with 3 m temperature sensor and power adapter, 2 RJ11 sensor ports, 2 DI, PoE - HW group 600753
Item HWG-600753Sensor splitter Poseidon T-Box RJ11 for up to 5 sensors, 5x RJ11, 1-Wire, with 10 cm cable - HW group 600356
Item HWG-600356Pt100/Pt1000 converter Converter 2xPt100 1W-UNI, 2 probe inputs, -200 to +850 °C, probes not included - HW group 600567
Item HWG-600567Pt100 probe Probe Pt100 TG8 2m, -50 to +200 °C, Pt100/A, 2 m silicone cable 4-wire, without converter - HW group 600614
Item HWG-600614Questions about this item
Any other question?
Send us the item number and your question. We clarify technical details directly with the manufacturer and usually reply on the next working day. Ask a question