Images are examples, some edited with AI. The technical data are authoritative. AI notice
Servo drive 300 VA 24 to 48 V DC CMMT-ST-C8-1C-MP-S0 - Festo 8163946
With 8 A nominal current per phase and 300 VA nominal power, the Festo CMMT-ST-C8-1C-MP-S0 servo drive powers electric axes (24 to 48 V DC load supply). Protocol: EtherCAT, EtherNet/IP, PROFINET IRT. Nominal power 300 VA, peak power 800 VA. 8 A nominal and 20 A peak current per phase for up to 3 s.
- Specialist dealer since 2009
- Invoice payment for regular customers
- Worldwide shipping
- Technical questions clarified with the manufacturer
Description
With 8 A nominal current per phase and 300 VA nominal power, the Festo CMMT-ST-C8-1C-MP-S0 servo drive powers electric axes (24 to 48 V DC load supply).
Key benefits
- Nominal power 300 VA, peak power 800 VA
- 8 A nominal and 20 A peak current per phase for up to 3 s
- Load supply 24 to 48 V DC
- Fieldbus and network connectivity: EtherCAT, EtherNet/IP, PROFINET IRT
- 6 digital inputs and 2 digital outputs 24 V DC
Areas of use
The drive runs on extra-low voltage (24 to 48 V DC) and is integrated via EtherCAT, EtherNet/IP, PROFINET IRT. It mounts on a DIN rail.
Technical data
| Type | CMMT-ST-C8-1C-MP-S0 |
|---|---|
| Festo part number | 8163946 |
| Type of mounting | via DIN rail |
| Mounting position | Open convection, vertical |
| Product weight | 350 g |
| Display | Green/yellow/red LED |
| Approval | RCM Mark, c UL us - Listed (OL) |
| KC mark | KC-EMV |
| CE mark (see declaration of conformity) | To EU EMC Directive, to EC Machinery Directive, in accordance with EU RoHS Directive |
| UKCA marking (see declaration of conformity) | To UK regulations for machines, to UK RoHS instructions |
| Certificate issuing authority | TÜV Rheinland UK 01/205U/5696.01/24, TÜV Rheinland 01/205/5696.01/24, UL E331130 |
| Storage temperature | -25 to 55 °C |
| Ambient temperature | 0 to 50 °C |
| Note on ambient temperature | Observe the derating regarding the mounting clearance and output current |
| Relative air humidity | 5 - 90%, Non-condensing |
| Maximum installation height | 2000 m |
| Degree of protection | IP20 |
| Protection class | III |
| Overvoltage category | I |
| Pollution degree | 2 |
| Note on materials | RoHS compliant |
| LABS (PWIS) conformity | VDMA24364 zone III |
| Nominal voltage load voltage DC | 24 to 48 V |
| Permissible range for load power supply | -15% / +15% |
| Maximum intermediate circuit voltage DC | 60 V |
| Brake resistor, external | 6 Ohm |
| Maximum continuous output of the external braking resistor (IEC) | 490 W |
| Nominal voltage for logic power supply DC | 24 V |
| Permissible range for logic voltage | ±15% |
| Current consumption of logic power supply without clamping brake | 1 A |
| Current consumption for logic supply with parking brake | 2 A |
| Output voltage range AC | 0 V up to input voltage |
| Nominal output current | 8 A |
| Nominal current per phase, effective | 8 A |
| Peak current per phase, effective | 20 A |
| Maximum peak current duration | 3 s |
| Nominal controller power | 300 VA |
| Peak power | 800 VA |
| Output frequency | 0 to 20000 Hz |
| Maximum length of motor cable without external mains filter | 25 m |
| Maximum output current of holding brake | 1 A |
| Maximum voltage drop from logic supply to brake output | 1 V |
| Controller operating mode | Cascade controller, P position controller, PI speed controller, PI current controller for F or M, Profile operation with record and direct mode, Interpolated mode via fieldbus, Synchronised operating modes, Homing, Setting-up, Autotuning, Open-loop operation |
| Operating mode | Field-oriented closed-loop control, Position resolution 24 bit/rev., Real-time data acquisition, 2x Input capture (x, v, F), 2x Output trigger (x, v, F), 1x position encoder input, Sampling rate 16 or 20 kHz, PWM with 16 or 20 KHz |
| Adjustable current reduction | about software |
| Protective function | I²t monitoring, Temperature monitoring, Current monitoring, Voltage failure detection, Following error monitoring, Software end-position detection |
| Nominal current setting | about software |
| Ethernet interface, function | Parameterisation and commissioning |
| Ethernet interface, protocol | TCP/IP |
| Field bus, protocol | EtherCAT, EtherNet/IP, PROFINET IRT |
| Fieldbus interface, function | Bus connection incoming/outgoing, EtherCAT slave, PROFINET slave, Fieldbus |
| Fieldbus link | EtherCAT, EtherNet/IP, Modbus/TCP, PROFINET |
| Communication profile | CiA402, CoE (CANopen over EtherCAT), EoE (Ethernet over EtherCAT), FoE (File over EtherCAT), PROFIdrive |
| Process interfacing | I/O mode for 256 positioning records, Interpolated mode CSP, Interpolated mode CST, Interpolated mode CSV |
| Field bus interface, transmission rate | 100 Mbit/s |
| Field bus, connection type | 2x socket |
| Field bus, connection system | RJ45 |
| Encoder interface, function | BiSS-C, Incremental encoder |
| Number of digital logic inputs | 6 |
| Switching logic for inputs | PNP (positive switching) |
| Features of logic input | Freely configurable in some cases, Safety inputs in some cases, Not galvanically isolated |
| Specification logic input | Based on IEC 61131-2, type 3 |
| Working range of logic input | -3 to 30 V |
| Number of high-speed logic inputs | 2 |
| Time resolution of high-speed logic inputs | 1 µs |
| Number of digital logic outputs 24 V DC | 2 |
| Switching logic for outputs | PNP (positive switching) |
| Features of digital logic outputs | Not galvanically isolated |
| Maximum current digital logic outputs | 100 mA |
| Number of high-speed switching outputs | 2 |
| Time resolution of high-speed switching outputs | 1 µs |
| Number of floating switching outputs | 1 |
| Maximum current of the floating switching outputs | 100 mA |
| Safety function | Safe torque off (STO), Safe stop 1 time controlled (SS1-t) |
| Safety Integrity Level (SIL) | STO/SIL 2/SILCL 2 (EC motor without diagnostics), STO/SIL 3/SILCL 3 (stepper motor/EC motor with diagnostics) |
| Performance Level (PL) | STO/Cat, 3, PLd (EC motor without diagnostics), STO/Cat, 3, PLe (stepper motor/EC motor with diagnostics) |
| Diagnostic coverage | STO / medium (EC motor without diagnostics), STO / medium (stepper motor), STO / low (EC motor without diagnostics) |
| SFF Safe Failure Fraction | 99 % |
| Hardware fault tolerance | 1 |
| Proof test interval | STO/20 a (stepper motor/EC motor without diagnostics), STO: 0.25 a (EC motor with diagnostics) |
| Number of safe 2-pin inputs | 1 |
| Number of diagnostic outputs | 1 |
| Weight | 0.47 kg |
| Manufacturer | Festo |
| Hersteller-Nr | CMMT-ST-C8-1C-MP-S0 |
| EAN | 4052568631956 |
| Zolltarifnummer | 85044095 |
| GPSR Herstellerdaten | Festo Vertrieb GmbH&Co. KG, Festo Campus 1, DE-73734 Esslingen, festo.com |
| Artikelzustand | New |
| Artikel-Authentizität | Original product |
| Protection rating | IP20 |
| Temperaturbereich | 0-50 °C |
| Temperature (max.) | 50 |
Downloads
Questions about this item
Any other question?