Flow sensor 5 to 100 l/min for liquids G1 IO-Link SFAW-100T-TG1-E-PNLK-PNVBA-M12 - Festo 8036878

Festo ✓ Original product Brand new

The flow sensor SFAW-100T-TG1-E-PNLK-PNVBA-M12 is designed for flow rate and temperature of liquids between 5 l/min and 100 l/min. Outputs of the SFAW: two switching outputs, PNP or NPN selectable, plus analogue output 0 - 10 V, 4 - 20 mA, 1 - 5 V and IO-Link. Operating pressure 0 to 12 bar, connection female thread G1.

Net
€439.66
excl. VAT
Item FES-8036878
Manufacturer no. SFAW-100T-TG1-E-PNLK-PNVBA-M12
Question about this item
  • Specialist dealer since 2009
  • Invoice payment for regular customers
  • Worldwide shipping
  • Technical questions clarified with the manufacturer

Description

With the Festo SFAW-100T-TG1-E-PNLK-PNVBA-M12 you record flow rate and temperature within 5 to 100 l/min and evaluate the values on the device or in the controller.

Benefits

  • Measuring range 5 to 100 l/min
  • Measurement method Temperature: PT1000, Flow: Vortex
  • Additional temperature measurement 0 to 90 °C
  • Switching output 2 x PNP or 2 x NPN, switchable, analogue output 0 - 10 V, 4 - 20 mA, 1 - 5 V and IO-Link
  • Operating pressure 0 to 12 bar, degree of protection IP65

Applications

Operating medium of the SFAW-100T-TG1-E-PNLK-PNVBA-M12: liquid media, neutral fluids, water, flow direction P1 to P2, unidirectional. Typical tasks up to 100 l/min include monitoring cooling and process water circuits. The SFAW-100T-TG1-E-PNLK-PNVBA-M12 runs on 18 to 30 V DC.

Technical data

TypeSFAW-100T-TG1-E-PNLK-PNVBA-M12
Festo part number8036878
ApprovalRCM, c UL us - Listed (OL)
CE mark (see declaration of conformity)To EU EMC Directive, to EU RoHS Directive
KC markKC-EMV
Note on materialsRoHS compliant
Measured variableflow, temperature
Flow directionP1 to P2, Unidirectional
Measurement methodTemperature: PT1000, Flow: Vortex
Start value for flow rate measuring range5 l/min
End value for flow rate measuring range100 l/min
Operating pressure0 to 12 bar
Note on operating pressuremax. 12 bar at 40 °C, max. 6 bar at 100 °C
Operating mediumLiquid media, Neutral fluids, Water
Note on operating and pilot mediumCompatibility of the medium with the wetted materials must be ensured
Media temperature0 to 90 °C
Ambient temperature0 to 50 °C
Nominal temperature23 °C
Accuracy temperature in ± °C2 °C
Temperature coefficient span in ± %FS/Ktyp. ±0.05%FS/K
Switching output2 x PNP or 2 x NPN, switchable
Switching functionWindow comparator, Threshold comparator, Freely programmable
Switching element functionNC or NO, switchable
Max. output current100 mA
Analogue output0 - 10 V, 4 - 20 mA, 1 - 5 V
Flow characteristic curve start value0 l/min
Flow characteristic curve end value100 l/min
Max. load resistance current output500 Ohm
Min. load resistance voltage output15 kOhm
Short circuit current ratingYes
Overload protectionAvailable
ProtocolIO-Link
IO-Link, protocol versionDevice V 1.1
IO-Link, profileSmart sensor profile
IO-Link, function classesTeach channel, Diagnostics, Identification, Binary data channel (BDC), Process data variable (PDV)
IO-Link, communication modeCOM2 (38.4 kBaud)
IO-Link, SIO mode supportYes
IO-Link, port typeA
IO-Link, process data width OUT0 bytes
IO-Link, process data width IN5 Byte
IO-Link, process data content IN1 bit BDC (volume monitoring), 14 bit PDV (measured flow value), 1 bit BDC (temperature monitoring), 14 bit PDV (measured temperature value), 2 bit BDC (flow monitoring)
IO-Link, service data content IN32 bit measured volume value
IO-Link, minimum cycle time5 ms
IO-Link, data storage required500 Byte
Operational voltage range DC18 to 30 V
Reverse polarity protectionFor all electrical connections
Electrical connectionM12x1, 5-pin, straight plug, A-coded
Max. cable length30 m, 20 m in IO-Link mode
Mounting positionAny
Fluid connectionFemale thread G1
Product weight400 g
Material housingReinforced PA
Material in contact with the mediumEPDM (perox.), ETFE, stainless steel, reinforced PA6T/6I
Displayable unitsUS gal, US gal/min, cft, cft/min, l, l/h, l/min, m3, °C, °F
Degree of protectionIP65
Corrosion resistance class CRC3 - high corrosion stress
Temperature measuring range start value0 °C
Temperature measuring range end value90 °C
Temperature characteristic curve start value0 °C
Temperature characteristic curve end value100 °C
Weight0.48 kg
ManufacturerFesto
Hersteller-NrSFAW-100T-TG1-E-PNLK-PNVBA-M12
EAN4052568285340
Zolltarifnummer90261021
GPSR HerstellerdatenFesto Vertrieb GmbH&Co. KG, Festo Campus 1, DE-73734 Esslingen, festo.com
ArtikelzustandNew
Artikel-AuthentizitätOriginal product
MaterialPolyamide (PA)
ThreadG 1
Medientemperatur [°C]0 bis 90
Operating voltage18-30 V
SeriesSFAW
Betriebsdruck max [bar]12
Pneumatic connectionG1
Protection ratingIP65
Temperaturbereich0-50 °C
Temperature (max.)50