Images are examples, some edited with AI. The technical data are authoritative. AI notice

Analogue output module 4 outputs IP20 CPX-E-4AO-U-I - Festo 4080494

Festo ✓ Original product Brand new

Festo analogue output module CPX-E-4AO-U-I at a glance: 4 outputs, degree of protection IP20, grid dimension 18.9 mm. As part of the CPX-E series, the module extends the periphery of a controller with additional channels.

Net
€345.26
excl. VAT
Item FES-4080494
Manufacturer no. CPX-E-4AO-U-I
Question about this item
  • Specialist dealer since 2009
  • Invoice payment for regular customers
  • Worldwide shipping
  • Technical questions clarified with the manufacturer

Description

The CPX-E-4AO-U-I belongs to the Festo CPX-E series. As part of the CPX-E series, the module extends the periphery of a controller with additional channels.

Benefits

  • 4 outputs
  • Degree of protection IP20
  • Grid dimension 18.9 mm
  • Signal range -10 - 10 V, -20 - 20 mA, -5 - 5 V, 0 - 10 V, 0 - 20 mA, 4 - 20 mA
  • Ambient temperature -5 to 50 °C
  • Dimensions 18.9 mm x 76.6 mm x 124.3 mm

Applications

Used in automation solutions based on the Festo CPX-E series. Ambient temperature -5 to 50 °C, protection IP20.

Technical data

FeatureValue
TypeCPX-E-4AO-U-I
Festo part number4080494
Dimensions (W x L x H)18.9 mm x 76.6 mm x 124.3 mm
Grid dimension18.9 mm
Number of outputs4
Diagnostics via LEDerror per channel, error per module
Diagnostics via busgeneral error, short circuit/overload actuator supply, short circuit/overload analogue output, parameterisation error, above nominal range, below nominal range, undervoltage load supply
Module parametersdeactivate actuator supply, data format analogue outputs, short circuit diagnostics actuator supply, parameterisation error diagnostics, undervoltage diagnostics load supply, behaviour after short circuit/overload actuator supply, Behaviour after short circuit/overload at analogue output
Channel parametersforce channel x, enable wire break/open circuit diagnostics, enable parameterisation error diagnostics, enable overload/short circuit diagnostics, signal range per channel
Fuse protection (short circuit)Internal electronic fuse per module
Intrinsic current consumption at nominal operating voltage loadtypical 15 mA
Maximum residual current outputs per module2 A
Nominal operating voltage DC outputs24 V
Isolation channel - internal busYes
Isolation channel - channelNo
Permissible voltage fluctuations outputs± 25 %
Power supply, connection type2x terminal strip
Power supply, connection systemSpring-loaded terminal
Power supply, number of pins/wires4
Power supply, conductor diameter0.2 to 1.5 mm²
Power supply, note on conductor diameter0.2 - 2.5 mm² for flexible conductors without wire ferrule
ApprovalRCM
CE mark (see declaration of conformity)to EU EMC Directive
Vibration resistanceTransport application test with severity level 1 to FN 942017-4 and EN 60068-2-6
Shock resistanceShock test with severity level 1 to FN 942017-5 and EN 60068-2-27
Corrosion resistance class CRC0 - no corrosion stress
Storage temperature-20 to 70 °C
Relative air humidity95%, Non-condensing
Protection against direct and indirect contactprotective extra-low voltage (PELV)
Degree of protectionIP20
Ambient temperature-5 to 50 °C
Note on ambient temperature-5 - 60 °C for vertical installation
Max address volume outputs8 Byte
Electrical connection output, functionAnalogue output
Electrical connection output, connection type4x terminal strip
Electrical connection output, connector systemSpring-loaded terminal
Electrical connection output, number of connections/cores4
Electrical connection for output, conductor cross section0.2 to 1.5 mm²
Electrical connection for output, note on conductor cross section0.2 - 2.5 mm² for flexible conductors without wire ferrule
Type of mountingvia DIN rail
Note on materialscontains paint-wetting impairment substances (LABS), RoHS compliant
Material housingPA
Intrinsic current consumption at nominal operating voltage for electronics/sensorstypical 60 mA
Nominal DC operating voltage, electronics/sensors24 V
Permissible voltage fluctuations for electronics/sensors± 25 %
Measured variableVoltage, Current
Repetition accuracy±0.05 % at 25 °C
Operating error limit related to the ambient temperature range±0.3 %
Basic error limit at 25 °C±0.1 %
Power failure bridging10 ms
Analog input-10 - 10 V, -20 - 20 mA, -5 - 5 V, 0 - 10 V, 0 - 20 mA, 4 - 20 mA
Data format15 bits + prefix, Linear scaling
Maximum cable length30 m, Shielded
Electrical connection for output 2, functionfunctional earth
Electrical connection for output 2, connection typeTerminal strip
Electrical connection for output 2, connection technologySpring-loaded terminal
Electrical connection output 2, number of pins/wires4
Electrical connection output 2, pin allocation009958
Weight (price list)0.11 kg
Weight0.11 kg
ManufacturerFesto
Hersteller-NrCPX-E-4AO-U-I
EAN4052568291143
Zolltarifnummer85389099
GPSR HerstellerdatenFesto Vertrieb GmbH&Co. KG, Festo Campus 1, DE-73734 Esslingen, festo.com
ArtikelzustandNew
Artikel-AuthentizitätOriginal product
MaterialPolyamide (PA)
Operating conditionsEN 60068-2-27, EN 60068-2-6
SeriesCPX
Protection ratingIP20
Temperature (max.)50

Downloads

Accessories

Questions about this item

Any other question?