Images are examples, some edited with AI. The technical data are authoritative. AI notice
5/3-way solenoid valve, pilot-operated, exhaust centre, G 1/2, 1350 l/min, 12 V DC - E.MC
Pilot-operated 5/3-way solenoid valve from the E.MC RV series for 12 V DC, G 1/2 ports, 1350 l/min. With its exhaust centre it leaves the actuator depressurised at rest. IP65 protection and a response time below 0.05 s.
- Specialist dealer since 2009
- Invoice payment for regular customers
- Worldwide shipping
- Technical questions clarified with the manufacturer
Description
When an actuator has to stop in a defined way rather than just extend and retract, it needs a third switching position. The pilot-operated valve from the E.MC RV series switches with two 12 V DC coils and passes up to 1350 l/min at its G 1/2 port. With neither coil energised, the spool sits in the centre position. Both working ports are then open to exhaust. The actuator is depressurised and can be pushed by hand.
Advantages
- IP65 protection to DIN 40050 and insulation class F, each coil draws 3 W.
- Flow rate of 1350 l/min at 6.2 mm nominal diameter and 30 mm² effective area (Cv 1.67), enough air for brisk strokes without the valve throttling them.
- Valve body and spool in aluminium alloy, HNBR O-rings, pilot unit in engineering plastic.
- Service life of at least 40 million switching cycles, roughly 11,000 operating hours at one cycle per second.
Applications
- Large-volume cylinders and rotary actuators that need 1350 l/min at a G 1/2 port.
- Setting up and adjusting fixtures where the cylinder has to be moved by hand at rest.
- Mobile equipment and battery-powered systems running on 12 V DC.
Accessories and spare parts
A matching 12 V DC replacement coil, type T1, is available separately. For wiring with plug-in connectors, E.MC lists connection cables in 0.3, 0.6 and 1 m lengths.
Technical data
| Feature | Value |
|---|---|
| Switching function | 5/3-way, exhaust centre |
| Actuation | solenoid, pilot-operated, both sides |
| Coil voltage | 12 V DC |
| Voltage tolerance | -15 % to +10 % |
| Power consumption per coil | 3 W |
| Coil | type T1, connector size 1 |
| Protection class | IP65 (DIN 40050) |
| Insulation class | F |
| Response time | below 0.05 s |
| Max. switching frequency | 3 cycles/s |
| Working ports (3x) | G 1/2 |
| Exhaust ports (2x) | G 1/2 |
| Nominal diameter | 6.2 mm |
| Flow rate | 1350 l/min |
| Effective area | 30 mm² (Cv 1.67) |
| Operating pressure | 1.5 to 8 bar (0.15 to 0.8 MPa) |
| Test pressure | 12 bar |
| Medium | compressed air, filtered to 40 µm, lubricated or non-lubricated |
| Temperature | -20 to 70 °C, non-freezing |
| Materials | valve body and spool aluminium alloy, HNBR O-rings, POM piston, copper coil, pilot unit engineering plastic |
| Service life | min. 40 million cycles |
| Weight | 750 g |
| Scope of delivery | valve, with coils and plug connectors supplied loose |
| Dimension drawing | in the E.MC datasheet (PDF) |
| Manufacturer | E.MC |
| Hersteller-Nr | RV 5342-15E-12V= |
| EAN | 4050571716653 |
| Zolltarifnummer | 84812090 |
| GPSR Herstellerdaten | A1-ESD equipment GmbH. Keldersstr. 15, DE-42697 Solingen, www.esd.equipment |
| Artikelzustand | New |
| Artikel-Authentizität | Original product |
| Nominal size DN [mm] | 6,2 |
| Function | Mittelstellung entlüftet |
| Flow rate [l/min] | 1350 |
| Gewinde Abluft (2x) | G 1/2 |
| Leistungsaufnahme (DC) [W] | 3 |
| Operating voltage | 12 V DC |
| Temperaturbereich | -20-70 °C |
Downloads
Accessories
Questions about this item
Any other question?