Wherever compressed air has to be redirected quickly and repeatably, this 5/2-way solenoid valve sits between the service unit and the actuator. The connection G 1/8" provides 500 l/min. The switching function is Impulse valve. The operating pressure is stated as 1.5 to 8 bar. The materials are body and spool aluminium, seals NBR, pilot polyamide.
Advantages
- Control voltage tolerance plus/minus 10 percent, which makes short supply dips uncritical.
- Media oiled and non-oiled, filtered compressed air, so no separate treatment is needed.
- Flow rate of 500 l/min, so the connected actuator moves without the valve throttling it.
- Switching function Impulse valve, so the rest position is clearly defined.
- Control with 24 V DC at a power consumption of 2.8 W, which relieves the supply when many valves share one cabinet.
Technical data
| Feature | Value |
|---|
| Function | Impulse valve |
|---|
| Switching function | 5/2-way |
|---|
| Control voltage | 24 V DC |
|---|
| Thread G1 (3x) | G 1/8" |
|---|
| Exhaust thread G2 (2x) | G 1/8" |
|---|
| Nominal diameter [mm] | 3.9 |
|---|
| Flow rate [l/min] | 500 |
|---|
| Power consumption (DC) [W] | 2.8 |
|---|
| Dimensions [mm] | A 143.2, B 27, C 18, D 9.5, E 64.6, F 14, H1 3.3, H2 3.3, J 13, K 56.6, L 30, M 57.6, N 28, O 63.6, P 3, S 16, T 71.6, U 55.2, V 33.9, W 2 |
|---|
| Material body and spool | aluminium |
|---|
| Material seals | NBR |
|---|
| Material pilot | polyamide |
|---|
| Temperature range | -5 to +60 °C |
|---|
| Operating pressure | 1.5 to 8 bar |
|---|
| Media | oiled and non-oiled, filtered compressed air |
|---|
| Switching time (at 5 bar) | below 50 ms, max. 5 switching cycles / sec. (5/3-way: max. 3 switching cycles / sec.) |
|---|
| Control voltages | Standard: 24 V DC, 230 V AC, other voltages on request |
|---|
| Voltage tolerance | plus/minus 10 percent |
|---|
| Protection class | IP 65 |
|---|
| Service life | min. 40 million switching cycles |
|---|
Applications
- Cycled feeding and clamping units in fixture building.
- Plants operated within the temperature range -5 to +60 °C.
- Replacement of a defective valve of the same type in existing machines.
- Control of double-acting cylinders with an air demand up to 500 l/min.