Wherever compressed air has to be redirected quickly and repeatably, this 5/2-way solenoid valve sits between the service unit and the actuator. The connection G 3/8" provides 2000 l/min. The switching function is Impulse valve. The operating pressure is stated as 1.5 to 10 bar. The materials are body and spool aluminium, seals NBR, pilot polyamide (glass fibre reinforced).
Advantages
- Materials body and spool aluminium, seals NBR, pilot polyamide (glass fibre reinforced), matched to the intended service.
- Protection class IP 65 at the solenoid coil, suitable for dusty surroundings.
- Temperature range of -10 to +60 °C, which covers use in the machine room as well as outdoors.
- Connection G 3/8" and exhaust G 3/8", so the piping follows the existing line network.
- Control voltage tolerance plus/minus 10 percent, which makes short supply dips uncritical.
Technical data
| Feature | Value |
|---|
| Function | Impulse valve |
|---|
| Control voltage | 12 V DC |
|---|
| Thread (3x) | G 3/8" |
|---|
| Exhaust thread (2x) | G 3/8" |
|---|
| Flow rate [l/min] | 2000 |
|---|
| Operating pressure [bar] | 1.5 to 10 |
|---|
| Power consumption (DC) [W] | 2.1 |
|---|
| Material body and spool | aluminium |
|---|
| Material seals | NBR |
|---|
| Material pilot | polyamide (glass fibre reinforced) |
|---|
| Temperature range | -10 to +60 °C |
|---|
| Media | oiled and non-oiled, filtered compressed air |
|---|
| Switching time (at 5 bar) | below 30 ms |
|---|
| Control voltages | Standard: 24 V DC, 230 V AC, other voltages on request |
|---|
| Voltage tolerance | plus/minus 10 percent |
|---|
| Protection class | IP 65 |
|---|
Applications
- Replacement of a defective valve of the same type in existing machines.
- Control of double-acting cylinders with an air demand up to 2000 l/min.
- Sequencing of pneumatic axes with connection G 3/8" in handling equipment.
- Installation in control cabinets with a supply of 12 V DC.