Images are examples, some edited with AI. The technical data are authoritative. AI notice
Pneumatic interface VABA-S6-1-X5 - Festo 8154036
- Specialist dealer since 2009
- Invoice payment for regular customers
- Worldwide shipping
- Technical questions clarified with the manufacturer
Technical data
| Vibration resistance | Transport application test with severity level 2 to FN 942017-4 and EN 60068-2-6 |
|---|---|
| Note on vibration resistance | SG2 on wall mounting |
| Shock resistance | Shock test with severity level 2 to FN 942017-5 and EN 60068-2-27 |
| Note on shock resistance | SG2 on wall mounting |
| Valve terminal interface | Type 44, VTSA, Type 45, VTSA-F |
| Reverse polarity protection | Yes |
| Diagnostics via LED | Diagnostics per module, Load power supply |
| Diagnostics per internal communication | Communication error, Short-circuit/overload in output signal, Electronics/sensors overvoltage, Load overvoltage, Electronics/sensors undervoltage, Load undervoltage |
| Max. number of valve positions | 16 with double solenoid valves, 32 with single solenoid valves |
| Max. number of valve coils | 32 |
| Module code (hex/dec) | 0x3044/12356d |
| Module parameters | Activation of diagnostics in case of overload/short circuit, Condition counter limit value/actual value, Configuration of voltage monitoring load supply PL, Behaviour in error state |
| Internal cycle time | < 1 ms |
| Dimensions (W x L x H) | 70.5 mm x 142 mm x 102.6 mm |
| Fuse protection (short circuit) | Internal electronic fuse protection per valve output |
| Intrinsic current consumption at nominal operating voltage for electronics/sensors | Typical 27 mA |
| Intrinsic current consumption at nominal operating voltage load | Typical 17 mA |
| Note regarding operating voltage | SELV/PELV fixed power supplies required, Note the voltage drop |
| Nominal DC operating voltage, electronics/sensors | 24 V |
| Nominal operating voltage DC of load | 24 V |
| Power failure bridging | 10 ms |
| Potential separation between the supply voltages electronics/sensor technology and load/valves | Yes |
| Pollution degree | 2 |
| Permissible voltage fluctuations for electronics/sensors | ±25% |
| Permissible voltage fluctuation of load | ±10% |
| Undervoltage load/valves (diagnostic message) | 21.6 V |
| Corrosion resistance class CRC | 0 - No corrosion stress |
| LABS (PWIS) conformity | VDMA24364-B2-L |
| Storage temperature | -20 ... 70 °C |
| Relative air humidity | 5 - 95%, Non-condensing |
| Protection class | III |
| Overvoltage category | II |
| Ambient temperature | -20 ... 50 °C |
| Note on ambient temperature | Observe ambient temperature derating according to IEC 61131-2:2017 |
| Nominal altitude of use | <= 2000 m ASL (> 79.5 kPa) |
| Max. installation height | 3500 m |
| Note on max. installation height | > 2000 m ASL (< 79.5 kPa), Observe ambient temperature derating according to IEC 61131-2:2017 |
| Product weight | 1245 g |
| Electrical control | Fieldbus |
| Communication interface, protocol | AP |
| Type of mounting | Via through-hole for M6 screw |
| Note on materials | RoHS compliant, Free of halogen, Free of phosphoric acid ester |
| Material cover | Zinc die-cast metal, powder-coated |
| Material seals | NBR, PUR |
| Material housing | Aluminium |
| Material screws | Nickel-plated steel |
| Weight | 1.3 kg |
| Manufacturer | Festo |
| Hersteller-Nr | VABA-S6-1-X5 |
| EAN | 4052568614560 |
| Zolltarifnummer | 85389099 |
| GPSR Herstellerdaten | Festo Vertrieb GmbH&Co. KG, Festo Campus 1, DE-73734 Esslingen, festo.com |
| Artikelzustand | New |
| Artikel-Authentizität | Original product |
Downloads
Questions about this item
Any other question?
Send us the item number and your question. We clarify technical details directly with the manufacturer and usually reply on the next working day.