Energy monitor Perseus Energy 285, LTE, M-Bus master, 6 sensor ports, 4 DI, 2 relays, plain unit - HW group 600852
Perseus Energy 285 packs an M-Bus master, RS-485 Modbus/RTU, 4 S0 meter inputs, 2 relays rated up to 250 V and 6 RJ11 sensor ports into one DIN rail unit. Its built-in LTE modem keeps the link up during Ethernet outages and sends SMS and voice alerts directly. This plain unit ships without a cellular antenna.
- Specialist dealer since 2009
- Invoice payment for regular customers
- Worldwide shipping
- Technical questions clarified with the manufacturer
Description
Perseus Energy 285 brings a site's energy meters, room conditions and leak detection together in a single DIN rail device. It handles up to 100 meters with 1000 variables, and alerts still get out by SMS or voice call over the integrated LTE modem when the LAN is down.
Benefits
- Every utility covered: M-Bus master for up to 100 electricity, gas and water meters, plus RS-485 Modbus/RTU for UPS and HVAC equipment.
- Accurate pulse counting: 4 dry contact inputs with S0 counters to EN 62053-31 Class A.
- Power relays: 2 relay outputs rated 250 V and 10 A switch air conditioning, ventilation or doors based on readings.
- LTE backup: the internal modem reports power failures to the Portal and acts as SMS and call gateway for other HW group devices on the network.
- Mains powered: 230 V via terminal block, drawing 130 mA.
- Sensors and leaks: 6 RJ11 ports for 1-Wire UNI sensors and 1 WLD zone for a leak sensing cable.
Applications
- Energy monitoring in sub-distribution boards of server rooms and technical rooms
- Metering of electricity, gas and water consumption at remote sites
- Boiler rooms and heating plants
- Industrial machinery monitoring
- Greenhouses, food and pharmaceutical storage
Compatibility
- 1-Wire UNI sensors on RJ11: temperature, humidity (indoor and outdoor), voltage, current 0-30 A or 4-20 mA
- WLD water leak sensing cables
- Third-party M-Bus meters and Modbus/RTU devices
- Other HW group devices such as STE2 R2 via the Meters API over LAN
- SensDesk Technology portals, HWg Monitor app
Technical data
| Ethernet | RJ45, 10/100 Mbit, built-in web server |
|---|---|
| Cellular | LTE (global), external antenna with SMA connector |
| Sensor ports | 6 x RJ11 for 1-Wire UNI |
| Digital inputs | 4 x dry contact with S0 pulse counter (EN 62053-31, Class A) |
| Digital outputs | 2 x relay, max. 250 V, 10 A |
| Water leak | 1 WLD zone for sensing cable |
| RS-485 | 1 x terminal block, Modbus/RTU |
| M-Bus | 1 x terminal block, M-Bus master, up to 100 meters |
| Protocols | HTTP, HTTPS, SNMP v1 and v3, SNMP Trap, SMTP with TLS, SNTP, DHCP, IPv6, XML, MQTT, Modbus/TCP, BACnet/TCP |
| Meters API | 1-Wire, Modbus/RTU, M-Bus, Modbus/TCP, SNMP, MQTT, HWg XML |
| Capacity | up to 100 meters and 1000 variables, 32 MB data logger |
| Alerting | email, SMS and voice call via LTE, SNMP Trap, up to 100 destinations each |
| Data processing | conditions and actions, virtual sensors, scheduler, Lua scripts |
| Security | RADIUS (IEEE 802.1X), admin and user accounts, HTTPS with custom certificate |
| Power supply | 230 V via terminal block, 130 mA |
| Operating conditions | -30 to +65 °C, 5-95 % RH |
| Storage conditions | -30 to +85 °C, 5-95 % RH |
| Dimensions and weight | 213 x 90 x 65 mm (W x H x D), 529 g |
| Mounting | DIN rail |
| Housing | plastic, IP40 |
| Warranty | 24 months |
| Manufacturer part number | 600852 |
| Weight | 0.588 kg |
| Manufacturer | HW group |
| Hersteller-Nr | 600852 |
| Zolltarifnummer | 85176200 |
| GPSR Herstellerdaten | HW group s.r.o., Rumunská 26, CZ-120 00 Praha 2, www.hw-group.com |
| Artikelzustand | New |
| Artikel-Authentizität | Original product |
| Country of Manufacture | Czechia |
| Housing material | Plastic |
| Interface | Digital I/O, Ethernet, RS-485, 1-Wire, Mobilfunk (LTE) |
| Operating voltage | 230 V AC |
| Protection rating | IP40 |
Scope of delivery
- Perseus Energy 285, plain unit
- Not included: power adapter (the unit is powered directly from 230 V)
- Not included: cellular antenna
- Also available as a set with LTE antenna under HW group 600871
Downloads
Datasheet
User Manual
Declaration of Conformity
Accessories
Antenna LTE/GSM 3m-cable SMA, quadband external antenna on 3 m cable with SMA connector - HW group 600530
Item HWG-600530Three-phase energy meter PRO380-Mb, 230/400 V, direct up to 100 A, M-Bus and S0, MID approved - HW group 600763
Item HWG-600763Three-phase energy meter PRO380-Mb x/5A M-Bus, CT-connected 3x230/400 V, 5 A, M-Bus and S0, MID - HW group 600764
Item HWG-600764Three-phase energy meter PRO380-Mod, direct connection 0.25-100 A, 3x230/400 V, Modbus RTU and S0, MID - HW group 600859
Item HWG-600859ESD version
Energy monitor Perseus Energy 285 set with LTE antenna, M-Bus master, 6 sensor ports, 4 DI, 2 relays - HW group 600871
Item HWG-600871Questions about this item
Any other question?
Send us the item number and your question. We clarify technical details directly with the manufacturer and usually reply on the next working day. Ask a question