Flowmeter with measuring section, flange connection DN 50 to DIN EN 1092-1, measuring range 2.0 to 1195 m³/h, calorimetric - Riegler 135882

Riegler ✓ Original product Brand new Made in Germany

Make consumption and leaks visible: flowmeter DN 50 with measuring section and flange connection DN 50 to DIN EN 1092-1, measuring range 2.0 to 1195 m³/h. Version DN 50: operating pressure up to 16 bar, -30 to 80 °C, supply 24 V DC, outputs analogue 4 - 20 mA, pulse output (galvanically separated). No additional pressure and temperature compensation is required.

Net
€2,111.89
excl. VAT
Item RGL-135882
Manufacturer no. DFMM50-FL50
Question about this item
  • Specialist dealer since 2009
  • Invoice payment for regular customers
  • Worldwide shipping
  • Technical questions clarified with the manufacturer

Description

Make consumption and leaks visible: flowmeter DN 50 with measuring section and flange connection DN 50 to DIN EN 1092-1, measuring range 2.0 to 1195 m³/h.

Version DN 50: operating pressure up to 16 bar, -30 to 80 °C, supply 24 V DC, outputs analogue 4 - 20 mA, pulse output (galvanically separated).

Benefits

  • Measuring range 2.0 to 1195 m³/h with measuring section DN 50, pipe I.D. 53.1 mm
  • Backlit display: current and total consumption, meter reading resettable via keypad
  • Display rotatable by 180°, measuring unit removable
  • analogue 4 - 20 mA, pulse output (galvanically separated) for connection to controls or energy monitoring
  • Flange connection DN 50 to DIN EN 1092-1, up to 16 bar

Applications

  • System monitoring of flow and consumption changes
  • Leakage and energy efficiency measurements in compressed air networks
  • Medium: compressed air, neutral gases

Technical data

Type no.DFMM50-FL50
Nominal size DN50 mm
Temperature range-30 to 80 °C
Operating pressureup to 16 bar
Flow rate outputAnalogue 4 - 20 mA, pulse output (galvanically separated)
Tube I.D.53.1 mm
Flow measuring range2.0 to 1195 m³/h
Dimension L475.0 mm
Dimension H1165.7 mm
Measuring systemCalorimetric measurement
MediumCompressed air, neutral gases
Operating voltage24 V DC
DisplayBackground lighting
FlangeDIN EN 1092-1
Flange-Ø D165 mm
Pitch circle Ø K125 mm
No. of bolt holes4 x 18
Weight10.24 kg
ManufacturerRiegler
Hersteller-NrDFMM50-FL50
EAN4047322501231
Zolltarifnummer90268020
GPSR HerstellerdatenRiegler & Co. KG, Schützenstraße 27, DE-72574 Bad Urach, www.riegler.de
ArtikelzustandNew
Artikel-AuthentizitätOriginal product
Country of ManufactureGermany
Nominal size DN [mm]50
NormDIN EN 1092-1
Betriebsdruck max [bar]16
Temperaturbereich-30-80 °C
Temperature (max.)80

Downloads