Technical data
| Dimensions (W x L x H) | 30 mm x 170 mm x 35 mm |
|---|---|
| Type of mounting | On DIN rail via accessories, With through-hole |
| Product weight | 129 g |
| Ambient temperature | -20 ... 60 °C |
| Storage temperature | -40 ... 70 °C |
| Relative air humidity | 5 - 95%, Non-condensing |
| Degree of protection | IP65, IP67 |
| Note on degree of protection | Unused connections sealed |
| Corrosion resistance class CRC | 1 - Low corrosion stress |
| Max. cable length | 30 m outputs, 30 m inputs, 50 m system communication |
| Note on max. cable length | Power supply according to nominal voltage |
| LABS (PWIS) conformity | VDMA24364-B2-L |
| Cleanroom suitability, measured according to ISO 14644-14 | Element installed statically, no meaningful evaluation possible according to ISO 14644-1 |
| CE mark (see declaration of conformity) | To EU EMC Directive |
| UKCA marking (see declaration of conformity) | To UK instructions for EMC |
| KC mark | KC-EMV |
| Approval | RCM, c UL us - Listed (Oil) |
| Certificate issuing authority | UL E239998 |
| Note on materials | RoHS compliant |
| Material housing | Makrolon®, Nickel-plated die-cast zinc |
| Material o-ring | Fluoro rubber |
| Diagnostics via LED | Diagnostics per module, Load power supply, Status per channel |
| Diagnostics per internal communication | Short-circuit/overload in output signal, Short circuit/overload in sensor supply, Electronics/sensors overvoltage, Load overvoltage, Electronics/sensors undervoltage, Load undervoltage |
| Number of outputs | 4 |
| Communication interface, function | System communication XF10 IN / XF20 OUT |
| Communication interface, connection type | 2x socket |
| Communication interface, connection technology | M8x1, D-coded according to EN 61076-2-114 |
| Communication interface, number of pins/cores | 4 |
| Communication interface, protocol | AP |
| Communication interface, screened | Yes |
| Power supply, function | Incoming electronics/sensors and load |
| Power supply, connection type | Plug |
| power supply, connection system | M8x1, A-coded to EN 61076-2-104 |
| Power supply, number of pins/wires | 4 |
| Power transmission, function | Outgoing electronics/sensors and load |
| Power transmission, connection type | Socket |
| Power transmission, connection technology | M8x1, A-coded to EN 61076-2-104 |
| Power transmission, number of pins/wires | 4 |
| Note regarding operating voltage | SELV/PELV fixed power supplies required, Note the voltage drop |
| Nominal operating voltage DC of load | 24 V |
| Permissible voltage fluctuation of load | ±25% |
| Nominal DC operating voltage, electronics/sensors | 24 V |
| Permissible voltage fluctuations for electronics/sensors | ±25% |
| Max. power supply | 2 x 4 A (external fuse required) |
| Intrinsic current consumption at nominal operating voltage for electronics/sensors | Typically 35 mA |
| Intrinsic current consumption at nominal operating voltage load | Typically 10 mA |
| Power failure bridging | 10 ms |
| Reverse polarity protection | Yes |
| Electrical connection input, function | Digital input |
| Electrical connection input, connection type | 4x socket |
| Electrical connection input, connector system | M8x1, A-coded to EN 61076-2-104 |
| Electrical connection input, number of connections/cores | 3 |
| Number of inputs | 4 |
| Characteristic for inputs | To IEC 61131-2, type 3 |
| Switching level | Signal 0: <= 5 V, Signal 1: ≥ 11 V |
| Switching logic for inputs | PNP (positive switching), 2-wire sensors to IEC 61131-2, 3-wire sensors to IEC 61131-2 |
| Input debounce time | 0.1 ms, 3 ms, 10 ms, 20 ms |
| Fuse protection of inputs (short circuit) | Internal electronic fuse per module |
| Max. residual current of inputs per module | 1.8 A |
| Electrical isolation of inputs between channels | No |
| Electrical isolation of inputs between channel – internal communication | Yes |
| Electrical connection output, function | Digital output |
| Electrical connection output, connection type | 4x socket |
| Electrical connection output, connector system | M8x1, A-coded to EN 61076-2-104 |
| Electrical connection output, number of connections/cores | 3 |
| Characteristic for outputs | To IEC 61131-2, type 0.5 |
| Switching logic for outputs | PNP (positive switching) |
| Fuse protection of outputs (short circuit) | Internal electronic fuse per channel |
| Output delay with ohmic load | Signal change 0->1: < 200 µs, Signal change 1->0: < 200 µs |
| Max. residual current outputs per module | 2 A |
| Electrical isolation of outputs between channels | No |
| Electrical isolation of outputs between channel - internal communication | Yes |
| Max. power supply per channel | 0.5 A |
| Weight | 0.145 kg |
| Manufacturer | Festo |
| Hersteller-Nr | CPX-AP-I-4DI4DO-M8-3P |
| EAN | 4052568453718 |
| Zolltarifnummer | 85389099 |
| GPSR Herstellerdaten | Festo Vertrieb GmbH&Co. KG, Festo Campus 1, DE-73734 Esslingen, festo.com |
| Artikelzustand | New |
| Artikel-Authentizität | Original product |
Downloads
Questions about this item
Any other question?
Send us the item number and your question. We clarify technical details directly with the manufacturer and usually reply on the next working day.