Images are examples, some edited with AI. The technical data are authoritative. AI notice
Analogue input module for CPX-AP-I, 4 inputs, 24 V DC, IP65 CPX-AP-I-4AI-U-I-RTD-M12 - Festo 8086606
The Festo analogue input module CPX-AP-I-4AI-U-I-RTD-M12 acquires analogue signals locally in the CPX-AP-I system. Festo specifies 4 inputs, nominal operating voltage 24 V DC and power failure bridging 10 ms. Further data: reverse polarity protection and IP65/IP67 protection.
- Specialist dealer since 2009
- Invoice payment for regular customers
- Worldwide shipping
- Technical questions clarified with the manufacturer
Description
The analogue input module CPX-AP-I-4AI-U-I-RTD-M12 acquires analogue signals locally in the CPX-AP-I system. The main data are 4 inputs and nominal operating voltage 24 V DC.
Advantages
- 4 inputs
- Nominal operating voltage 24 V DC
- Power failure bridging 10 ms
- Integrated reverse polarity protection
- IP65/IP67 protection for mounting directly on the machine
- Suitable for ambient temperatures of -20 to 60 °C
Application
CPX-AP-I-4AI-U-I-RTD-M12 is used when designing, extending and maintaining installations with the CPX-AP-I system.
Technical data
| Type | CPX-AP-I-4AI-U-I-RTD-M12 |
|---|---|
| Festo part number | 8086606 |
| Dimensions (W x L x H) | 30 mm x 170 mm x 35 mm |
| Type of mounting | On DIN rail via accessories, With through-hole |
| Product weight | 166 g |
| Ambient temperature | -20 to 60 °C |
| Storage temperature | -40 to 70 °C |
| Relative air humidity | 5 - 95%, Non-condensing |
| Degree of protection | IP65, IP67 |
| Note on degree of protection | Unused connections sealed |
| Corrosion resistance class CRC | 1 - Low corrosion stress |
| Max. cable length | 30 m inputs, 50 m system communication |
| LABS (PWIS) conformity | VDMA24364-B2-L |
| Cleanroom suitability, measured according to ISO 14644-14 | Element installed statically, no meaningful evaluation possible according to ISO 14644-1 |
| CE mark (see declaration of conformity) | To EU EMC Directive |
| UKCA marking (see declaration of conformity) | To UK instructions for EMC |
| KC mark | KC-EMV |
| Approval | RCM, c UL us - Listed (Oil) |
| Certificate issuing authority | UL E239998 |
| Note on materials | RoHS compliant |
| Material housing | Makrolon, Nickel-plated die-cast zinc |
| Material seals | NBR |
| Material o-ring | Fluoro rubber |
| Diagnostics via LED | Diagnostics per module, Status per channel |
| Diagnostics per internal communication | Wire breakage, Module error, Short circuit/overload in sensor supply, Parameter error, Parameterisation error, Overload analogue inputs, Upper limit value violated, Underflow/overflow, Lower limit value not observed |
| Communication interface, function | System communication XF10 IN / XF20 OUT |
| Communication interface, connection type | 2x socket |
| Communication interface, connection technology | M8x1, D-coded according to EN 61076-2-114 |
| Communication interface, number of pins/cores | 4 |
| Communication interface, protocol | AP |
| Communication interface, screened | Yes |
| Power supply, function | Incoming electronics/sensors and load |
| Power supply, connection type | Plug |
| Power supply, connection system | M8x1, A-coded to EN 61076-2-104 |
| Power supply, number of pins/wires | 4 |
| Power transmission, function | Outgoing electronics/sensors and load |
| Power transmission, connection type | Socket |
| Power transmission, connection technology | M8x1, A-coded to EN 61076-2-104 |
| Power transmission, number of pins/wires | 4 |
| Note regarding operating voltage | SELV/PELV fixed power supplies required, Note the voltage drop |
| Nominal DC operating voltage, electronics/sensors | 24 V |
| Permissible voltage fluctuations for electronics/sensors | ± 25 % |
| Max. power supply | 2 x 4 A (external fuse required) |
| Intrinsic current consumption at nominal operating voltage for electronics/sensors | Typically 38 mA |
| Power failure bridging | 10 ms |
| Reverse polarity protection | Yes |
| Electrical connection input, function | Analogue input |
| Electrical connection input, connection type | 4x socket |
| Electrical connection input, connector system | M12x1, A-coded to EN 61076-2-101 |
| Electrical connection input, note on connector system | To achieve compliance with the technical specifications, the opposite side must be screened and designed with gold contact surfaces. |
| Electrical connection input, number of connections/cores | 5 |
| Number of inputs | 4 |
| Fuse protection of inputs (short circuit) | Internal electronic fuse per module |
| Max. residual current of inputs per module | 1 A |
| Electrical isolation of inputs between channels | No |
| Electrical isolation of inputs between channel - internal communication | Yes |
| Measured variable | Voltage, Current, Temperature, Resistor |
| Note on the measured variable | Temperature: PT100 and NI100 supported |
| Data format | 15 bits + prefix, Linear scaling |
| Signal range | -10 - 10 V, -5 - 5 V, 0 - 10 V, 1 - 5 V, 0 - 20 mA, 4 - 20 mA, 0 - 500 Ohm |
| Repetition accuracy | ±0.025% at 25°C |
| Basic error limit at 25 °C | ±0.1% for voltage, ±0.1 % for voltage, ±0.4% for temperature, ±0.2 % for resistance |
| Operating error limit related to the ambient temperature range | ±0.15% for voltage, ±0.15% for current, ±0.9 % for temperature, ±0.35% for resistor |
| Weight | 0.18 kg |
| Manufacturer | Festo |
| Hersteller-Nr | CPX-AP-I-4AI-U-I-RTD-M12 |
| EAN | 4052568550110 |
| Zolltarifnummer | 85389099 |
| GPSR Herstellerdaten | Festo Vertrieb GmbH&Co. KG, Festo Campus 1, DE-73734 Esslingen, festo.com |
| Artikelzustand | New |
| Artikel-Authentizität | Original product |
| Seal material | NBR |
| Operating voltage | 24 V DC |
| Protection rating | IP65 |
| Temperaturbereich | -20-60 °C |
| Temperature (max.) | 60 |
Downloads
Questions about this item
Any other question?
Send us the item number and your question. We clarify technical details directly with the manufacturer and usually reply on the next working day.