Technical data
| Dimensions (W x L x H) | 50.1 mm x 107.3 mm x 57.5 mm |
|---|---|
| Grid dimension | 50.1 mm |
| Type of mounting | Screw-clamped |
| Product weight | 98 g |
| Mounting position | Any |
| Ambient temperature | -20 ... 50 °C |
| Note on ambient temperature | Observe ambient temperature derating according to IEC 61131-2:2017 |
| Storage temperature | -20 ... 70 °C |
| Relative air humidity | 5 - 95%, Non-condensing |
| Nominal altitude of use | <= 2000 m ASL (> 79.5 kPa) |
| Max. installation height | 3500 m |
| Note on max. installation height | Observe ambient temperature derating according to IEC 61131-2:2017 |
| Corrosion resistance class CRC | 1 - Low corrosion stress |
| Vibration resistance | Transport application test with severity level 2 to FN 942017-4 and EN 60068-2-6 |
| Note on vibration resistance | Transport application test with severity class 1 to FN 942017-4 and EN 60068-2-6 |
| Shock resistance | Shock test with severity level 2 to FN 942017-5 and EN 60068-2-27 |
| Note on shock resistance | 30 g/11 ms to EN 60068-2-27, SG1 on DIN rail, SG2 on direct mounting, Shock test with severity level 1 to FN 942017-5 and EN 60068-2-27 |
| Protection class | III |
| Pollution degree | 2 |
| Overvoltage category | II |
| Max. cable length | 30 m outputs, 30 m inputs |
| LABS (PWIS) conformity | VDMA24364-B2-L |
| Fire test material | UL94 V-0 (housing) |
| Note on materials | RoHS compliant, Free of halogen, Free of phosphoric acid ester |
| Material cover | Reinforced PBT |
| Material screws | Nickel-plated steel |
| Material o-ring | Fluoro rubber |
| Diagnostics via LED | (Outputs) Diagnostics per channel, Power supply load (outputs), (Inputs-Outputs) Diagnostics per module, (Inputs-Outputs) Status per channel |
| Diagnostics per internal communication | Communication error, Short-circuit/overload in output signal, Short circuit/overload in sensor supply, Electronics/sensors overvoltage, Load overvoltage, Electronics/sensors undervoltage, Load undervoltage |
| Max. address volume, inputs | 2 byte |
| Max. address volume, outputs | 1 byte |
| Number of outputs | 4 |
| Module parameters | Configuration of voltage monitoring load supply PL, Behaviour after short circuit/overload at the output |
| Channel parameters | Input debounce time |
| Communication interface, protocol | AP |
| Note regarding operating voltage | SELV/PELV fixed power supplies required, Note the voltage drop |
| Note on nominal operating voltage DC | Protected Extra-Low-Voltage to IEC 60204-1 |
| Nominal operating voltage DC of load | 24 V |
| Permissible voltage fluctuation of load | ±25% |
| Nominal DC operating voltage, electronics/sensors | 24 V |
| Permissible voltage fluctuations for electronics/sensors | ±25% |
| Intrinsic current consumption at nominal operating voltage for electronics/sensors | Typically 40 mA |
| Intrinsic current consumption at nominal operating voltage load | Typically 5 mA |
| Power failure bridging | 10 ms |
| Potential separation between the supply voltages electronics/sensor technology and load/valves | Yes |
| Reverse polarity protection | Yes |
| Electrical connection input, function | Digital input |
| Electrical connection input, connection type | 6x socket |
| Electrical connection input, connector system | M12x1, A-coded to EN 61076-2-101 |
| Electrical connection input, number of connections/cores | 5 |
| Electrical connection input, connection pattern | 00995384 |
| Number of inputs | 12 |
| Characteristic for inputs | To IEC 61131-2, type 3 |
| Switching level | Signal 0: <= 5 V, Signal 1: ≥ 11 V |
| Switching logic for inputs | PNP (positive switching), 2-wire sensors to IEC 61131-2, 3-wire sensors to IEC 61131-2 |
| Input debounce time | 0.1 ms, 3 ms (standard), 10 ms, 20 ms |
| Electrical isolation of inputs between channel – internal communication | Yes |
| Behaviour after end of overload of the sensor supply | Automatic return |
| Fuse protection of inputs (short circuit) | Internal electronic fuse per module |
| Max. residual current of inputs per module | 1.8 A |
| Electrical isolation of inputs between channels | No |
| Electrical connection output, function | Digital output |
| Electrical connection output, connection type | 2x socket |
| Electrical connection output, connector system | M12x1, A-coded to EN 61076-2-101 |
| Electrical connection output, number of connections/cores | 5 |
| Electrical connection output, connection pattern | 00995384 |
| Characteristic for outputs | To IEC 61131-2, type 0.5 |
| Switching logic for outputs | PNP (positive switching) |
| Fuse protection of outputs (short circuit) | Internal electronic fuse per channel |
| Behaviour after end of overload of the outputs | No automatic return |
| Output delay with ohmic load | Signal change 0->1: < 200 µs, Signal change 1->0: < 200 µs |
| Max. residual current outputs per module | 2 A |
| Electrical isolation of outputs between channels | No |
| Electrical isolation of outputs between channel - internal communication | Yes |
| Max. power supply per channel | 0.5 A |
| Weight | 0.11 kg |
| Manufacturer | Festo |
| Hersteller-Nr | CPX-AP-A-12DI4DO-M12-5P |
| EAN | 4052568599492 |
| Zolltarifnummer | 85389099 |
| GPSR Herstellerdaten | Festo Vertrieb GmbH&Co. KG, Festo Campus 1, DE-73734 Esslingen, festo.com |
| Artikelzustand | New |
| Artikel-Authentizität | Original product |