Images are examples, some edited with AI. The technical data are authoritative. AI notice
Pressure sensor for vacuum 0 to -1 bar, 2x PNP, IO-Link, with display SPAU-V1R-T-G18M-LK-A-M12D - Festo 8003348
Measuring range 0 to -1 bar: the pressure sensor SPAU-V1R-T-G18M-LK-A-M12D detects relative pressure and switches via 2 PNP switching outputs, plus analogue output 4 to 20 mA. It connects pneumatically via G1/8 port and electrically via M12x1 plug (4-pin). LED display, setting via IO-Link.
Available
- Specialist dealer since 2009
- Invoice payment for regular customers
- Worldwide shipping
- Technical questions clarified with the manufacturer
Description
Designed for vacuum of 0 to -1 bar, the Festo pressure sensor SPAU-V1R-T-G18M-LK-A-M12D detects relative pressure and switches via 2 PNP switching outputs, plus analogue output 4 to 20 mA. Operating medium for SPAU-V1R-T-G18M-LK-A-M12D: compressed air and inert gases, medium temperature 0 to 50 °C.
Benefits
- Measuring range 0 to -1 bar, overload range up to 5 bar
- G1/8 port, electrical: M12x1 plug (4-pin)
- Rise time 3 ms, operating voltage 20 to 30 V DC
- Analogue output 4 to 20 mA, IO-Link (Device V 1.1) for parameterisation and diagnostics
- 2 PNP switching outputs, N/C or N/O switchable, output current up to 100 mA
- Accuracy 1.5 %FS, repeatability ± 0.3 %FS
Application
Typical tasks include vacuum monitoring on suction grippers, ejectors and vacuum circuits. SPAU-V1R-T-G18M-LK-A-M12D is mounted directly via the thread, in any position.
Technical data
| Type | SPAU-V1R-T-G18M-LK-A-M12D |
|---|---|
| Approval | RCM, c UL us - Listed (OL) |
| CE marking (see declaration of conformity) | To EU EMC Directive, to EU RoHS Directive |
| KC mark | KC EMC |
| Note on materials | RoHS-compliant |
| Measured variable | Relative pressure |
| Measuring method | Piezoresistive pressure sensor |
| Pressure measuring range initial value | 0 bar |
| Pressure measuring range full scale value | -1 bar |
| Overload range | 5 bar |
| Operating medium | Compressed air to ISO 8573-1:2010 [7:4:4], inert gases |
| Note on operating and pilot medium | Lubricated operation possible |
| Medium temperature | 0 to 50 °C |
| Ambient temperature | 0 to 50 °C |
| Resolution of analogue-digital converter | 12 Bit |
| Accuracy FS | 1.5 %FS |
| Repeatability in ± %FS | 0.3 %FS |
| Temperature coefficient in ± %FS/K | 0.05 %FS/K |
| Switching output | 2xPNP |
| Switching function | Freely programmable |
| Switching element function | N/C or N/O contact, switchable |
| Maximum output current | 100 mA |
| Analogue output | 4 - 20 mA |
| Rise time | 3 ms |
| Maximum load resistance current output | 500 Ohm |
| Minimum load resistance voltage output | 10 kOhm |
| Short circuit protection | Yes |
| Protocol | IO-Link |
| IO-Link, protocol | Device V 1.1 |
| IO-Link, Profile | Smart Sensor Profile |
| IO-Link, Function classes | Teach channel, diagnosis, identification, binary data channel (BDC), process data variable (PDV) |
| IO-Link, communication mode | COM2 (38.4 kBaud) |
| IO-Link, SIO-Mode support | Yes |
| IO-Link, port type | A |
| IO-Link, Process data length OUT | 0 Byte |
| IO-Link, Process data length IN | 2 Byte |
| IO-Link, Process data content IN | 14 bit PDV (pressure measured value), 2 bit BDC (pressure monitoring) |
| IO-Link, Min. cycle time | 3 ms |
| IO-Link, Data storage required | 500 Byte |
| Operating voltage range DC | 20 to 30 V |
| Reverse polarity protection | For all electrical connections |
| Electrical connection 1, connection type | Plug |
| Electrical connection 1, connector system | M12x1, A-coded to EN 61076-2-101 |
| Electrical connection 1, number of connections/cores | 4 |
| Type of mounting | With thread |
| Mounting position | Any |
| Pneumatic connection | G1/8 |
| Product weight | 80 g |
| Display type | LED |
| Displayable unit(s) | MPa, bar, inchH2O, inchHg, kPa, kgf/cm², mmHg, psi |
| Setting options | IO-Link |
| Tamper protection | IO-Link |
| Threshold setting range | 0 to 100 % |
| Hysteresis setting range | 0 to 90 % |
| Degree of protection | IP65, IP67 |
| Corrosion resistance class CRC | 2 - Moderate corrosion stress |
| Weight | 0.105 kg |
| Manufacturer | Festo |
| Hersteller-Nr | SPAU-V1R-T-G18M-LK-A-M12D |
| EAN | 4052568277307 |
| Zolltarifnummer | 90262020 |
| GPSR Herstellerdaten | Festo Vertrieb GmbH&Co. KG, Festo Campus 1, DE-73734 Esslingen, festo.com |
| Artikelzustand | New |
| Artikel-Authentizität | Original product |
| Thread | G 1/8 |
| Medium | Compressed air, neutral gases |
| Norm | DIN EN 61076-2-101 |
| Operating conditions | ISO 8573-1 |
| Series | SPAU |
| Protection rating | IP65 |
| Temperaturbereich | 0-50 °C |
| Temperature (max.) | 50 |
Downloads
Accessories
Connecting cable M8x1, 3-pin, 3-wire, socket, angled, open end 2.5 m SIM-M8-3WD-2,5-PSL-PU - Festo 159424
Item FES-159424Pressure sensor for vacuum 0 to -1 bar, 2x PNP, IO-Link, with display SPAU-V1R-T-G18M-LK-V-M12D - Festo 8003347
Item FES-8003347Pressure sensor for vacuum 0 to -1 bar, 2x PNP, IO-Link, with display SPAU-V1R-H-Q4D-LK-V-M12D - Festo 8003351
Item FES-8003351Pressure sensor for vacuum 0 to -1 bar, 2x PNP, IO-Link, with display SPAU-V1R-H-Q4D-LK-A-M12D - Festo 8003352
Item FES-8003352Pressure sensor for vacuum 0 to -1 bar, 2x PNP/NPN, IO-Link, with display SPAU-V1R-W-Q4D-L-PNLK-PNVBA - Festo 8001238
Item FES-8001238Pressure sensor for vacuum 0 to -1 bar, 2x PNP/NPN, IO-Link, with display SPAU-V1R-W-G18FD-L-PNLK-PNVBA - Festo 8001234
Item FES-8001234Questions about this item
Any other question?
Send us the item number and your question. We clarify technical details directly with the manufacturer and usually reply on the next working day.