Images are examples, some edited with AI. The technical data are authoritative. AI notice

Pressure sensor for vacuum 0 to -1 bar, 2x PNP, IO-Link, with display SPAU-V1R-H-Q4D-LK-V-M12D - Festo 8003351

Festo ✓ Original product Brand new

Designed for vacuum of 0 to -1 bar, the pressure sensor SPAU-V1R-H-Q4D-LK-V-M12D measures relative pressure and switches via 2 PNP switching outputs, plus analogue output 0 to 10 V. It connects pneumatically via push-in connector QS-4 and electrically via M12x1 plug (4-pin).

Net
€116.01
excl. VAT
Item FES-8003351
Manufacturer no. SPAU-V1R-H-Q4D-LK-V-M12D
Question about this item
  • Specialist dealer since 2009
  • Invoice payment for regular customers
  • Worldwide shipping
  • Technical questions clarified with the manufacturer

Description

The Festo pressure sensor SPAU-V1R-H-Q4D-LK-V-M12D measures relative pressure in the range 0 to -1 bar and switches via 2 PNP switching outputs, plus analogue output 0 to 10 V. Operating medium for SPAU-V1R-H-Q4D-LK-V-M12D: compressed air and inert gases, medium temperature 0 to 50 °C.

Benefits

  • Measuring range 0 to -1 bar, overload range up to 5 bar
  • Rise time 3 ms, operating voltage 20 to 30 V DC
  • LED display, setting via IO-Link
  • Push-in connector QS-4, electrical: M12x1 plug (4-pin)
  • Accuracy 1.5 %FS, repeatability ± 0.3 %FS
  • Degree of protection IP65, IP67, ambient temperature 0 to 50 °C

Application

Typical tasks include vacuum monitoring on suction grippers, ejectors and vacuum circuits. SPAU-V1R-H-Q4D-LK-V-M12D is mounted on a DIN rail, in any position.

Technical data

TypeSPAU-V1R-H-Q4D-LK-V-M12D
ApprovalRCM, c UL us - Listed (OL)
CE marking (see declaration of conformity)To EU EMC Directive, to EU RoHS Directive
KC markKC EMC
Note on materialsRoHS-compliant
Measured variableRelative pressure
Measuring methodPiezoresistive pressure sensor
Pressure measuring range initial value0 bar
Pressure measuring range full scale value-1 bar
Overload range5 bar
Operating mediumCompressed air to ISO 8573-1:2010 [7:4:4], inert gases
Note on operating and pilot mediumLubricated operation possible
Medium temperature0 to 50 °C
Ambient temperature0 to 50 °C
Resolution of analogue-digital converter12 Bit
Accuracy FS1.5 %FS
Repeatability in ± %FS0.3 %FS
Temperature coefficient in ± %FS/K0.05 %FS/K
Switching output2xPNP
Switching functionFreely programmable
Switching element functionN/C or N/O contact, switchable
Maximum output current100 mA
Analogue output0 - 10 V
Rise time3 ms
Maximum load resistance current output500 Ohm
Minimum load resistance voltage output10 kOhm
Short circuit protectionYes
ProtocolIO-Link
IO-Link, protocolDevice V 1.1
IO-Link, ProfileSmart Sensor Profile
IO-Link, Function classesTeach channel, diagnosis, identification, binary data channel (BDC), process data variable (PDV)
IO-Link, communication modeCOM2 (38.4 kBaud)
IO-Link, SIO-Mode supportYes
IO-Link, port typeA
IO-Link, Process data length OUT0 Byte
IO-Link, Process data length IN2 Byte
IO-Link, Process data content IN14 bit PDV (pressure measured value), 2 bit BDC (pressure monitoring)
IO-Link, Min. cycle time3 ms
IO-Link, Data storage required500 Byte
Operating voltage range DC20 to 30 V
Reverse polarity protectionFor all electrical connections
Electrical connection 1, connection typePlug
Electrical connection 1, connector systemM12x1, A-coded to EN 61076-2-101
Electrical connection 1, number of connections/cores4
Type of mountingWith DIN rail
Mounting positionAny
Pneumatic connectionQS-4
Product weight65 g
Display typeLED
Displayable unit(s)MPa, bar, inchH2O, inchHg, kPa, kgf/cm², mmHg, psi
Setting optionsIO-Link
Tamper protectionIO-Link
Threshold setting range0 to 100 %
Hysteresis setting range0 to 90 %
Degree of protectionIP65, IP67
Corrosion resistance class CRC2 - Moderate corrosion stress
Weight0.16 kg
ManufacturerFesto
Hersteller-NrSPAU-V1R-H-Q4D-LK-V-M12D
EAN4052568277338
Zolltarifnummer90262020
GPSR HerstellerdatenFesto Vertrieb GmbH&Co. KG, Festo Campus 1, DE-73734 Esslingen, festo.com
ArtikelzustandNew
Artikel-AuthentizitätOriginal product
For hose OD [mm]4
MediumCompressed air, neutral gases
NormDIN EN 61076-2-101
Operating conditionsISO 8573-1
SeriesSPAU
Protection ratingIP65
Temperaturbereich0-50 °C
Temperature (max.)50

Downloads

Accessories

Questions about this item

Any other question?

Send us the item number and your question. We clarify technical details directly with the manufacturer and usually reply on the next working day.