Images are examples, some edited with AI. The technical data are authoritative. AI notice
Pressure sensor for vacuum 0 to -1 bar, 2x PNP/NPN, IO-Link, with display SPAU-V1R-W-G18FD-L-PNLK-PNVBA - Festo 8001234
The pressure sensor SPAU-V1R-W-G18FD-L-PNLK-PNVBA monitors relative pressure in the range 0 to -1 bar and switches via 2 switching outputs, PNP/NPN switchable, plus analogue output 0 to 10 V, 4 to 20 mA or 1 to 5 V. G1/8 port, M8x1 plug (4-pin) and operating voltage 20 to 30 V DC.
Available
- Specialist dealer since 2009
- Invoice payment for regular customers
- Worldwide shipping
- Technical questions clarified with the manufacturer
Description
Measuring range 0 to -1 bar: the Festo pressure sensor SPAU-V1R-W-G18FD-L-PNLK-PNVBA monitors relative pressure and switches via 2 switching outputs, PNP/NPN switchable, plus analogue output 0 to 10 V, 4 to 20 mA or 1 to 5 V. Operating medium for SPAU-V1R-W-G18FD-L-PNLK-PNVBA: compressed air and inert gases, medium temperature 0 to 50 °C.
Benefits
- Measuring range 0 to -1 bar, overload range up to 5 bar
- Analogue output 0 to 10 V, 4 to 20 mA or 1 to 5 V, IO-Link (Device V 1.1) for parameterisation and diagnostics
- Degree of protection IP65, IP67, ambient temperature 0 to 50 °C
- 2 switching outputs, PNP/NPN switchable, N/C or N/O switchable, output current up to 100 mA
- G1/8 port, electrical: M8x1 plug (4-pin)
- Illuminated LCD, setting via teach-in, display and keys or IO-Link
Application
Typical tasks include vacuum monitoring on suction grippers, ejectors and vacuum circuits. Mounting is with a wall/surface bracket, in any mounting position.
Technical data
| Type | SPAU-V1R-W-G18FD-L-PNLK-PNVBA |
|---|---|
| Approval | RCM, c UL us - Listed (OL) |
| CE marking (see declaration of conformity) | To EU EMC Directive, to EU RoHS Directive |
| KC mark | KC EMC |
| Note on materials | RoHS-compliant |
| Measured variable | Relative pressure |
| Measuring method | Piezoresistive pressure sensor |
| Pressure measuring range initial value | 0 bar |
| Pressure measuring range full scale value | -1 bar |
| Overload range | 5 bar |
| Operating medium | Compressed air to ISO 8573-1:2010 [7:4:4], inert gases |
| Note on operating and pilot medium | Lubricated operation possible |
| Medium temperature | 0 to 50 °C |
| Ambient temperature | 0 to 50 °C |
| Resolution of analogue-digital converter | 12 Bit |
| Accuracy FS | 1.5 %FS |
| Repeatability in ± %FS | 0.3 %FS |
| Temperature coefficient in ± %FS/K | 0.05 %FS/K |
| Switching output | 2x PNP or 2x NPN, switchable |
| Switching function | Freely programmable |
| Switching element function | N/C or N/O contact, switchable |
| Maximum output current | 100 mA |
| Analogue output | 0 - 10 V, 4 - 20 mA, 1 - 5 V |
| Rise time | 3 ms |
| Maximum load resistance current output | 500 Ohm |
| Minimum load resistance voltage output | 10 kOhm |
| Short circuit protection | Yes |
| Protocol | IO-Link |
| IO-Link, protocol | Device V 1.1 |
| IO-Link, Profile | Smart Sensor Profile |
| IO-Link, Function classes | Teach channel, diagnosis, identification, binary data channel (BDC), process data variable (PDV) |
| IO-Link, communication mode | COM2 (38.4 kBaud) |
| IO-Link, SIO-Mode support | Yes |
| IO-Link, port type | A |
| IO-Link, Process data length OUT | 0 Byte |
| IO-Link, Process data length IN | 2 Byte |
| IO-Link, Process data content IN | 14 bit PDV (pressure measured value), 2 bit BDC (pressure monitoring) |
| IO-Link, Min. cycle time | 3 ms |
| IO-Link, Data storage required | 500 Byte |
| Operating voltage range DC | 20 to 30 V |
| Reverse polarity protection | For all electrical connections |
| Electrical connection 1, connection type | Plug |
| Electrical connection 1, connector system | M8x1, A-coded to EN 61076-2-104 |
| Electrical connection 1, number of connections/cores | 4 |
| Type of mounting | Via wall/surface bracket |
| Mounting position | Any |
| Pneumatic connection | G1/8 |
| Product weight | 70 g |
| Display type | Illuminated LCD |
| Displayable unit(s) | MPa, bar, inchH2O, inchHg, kPa, kgf/cm², mmHg, psi |
| Setting options | IO-Link, Teach-in, via display and keys |
| Tamper protection | IO-Link, PIN code |
| Threshold setting range | 0 to 100 % |
| Hysteresis setting range | 0 to 90 % |
| Degree of protection | IP65, IP67 |
| Corrosion resistance class CRC | 2 - Moderate corrosion stress |
| Weight | 0.1 kg |
| Manufacturer | Festo |
| Hersteller-Nr | SPAU-V1R-W-G18FD-L-PNLK-PNVBA# |
| EAN | 4052568277123 |
| Zolltarifnummer | 90262020 |
| GPSR Herstellerdaten | Festo Vertrieb GmbH&Co. KG, Festo Campus 1, DE-73734 Esslingen, festo.com |
| Artikelzustand | New |
| Artikel-Authentizität | Original product |
| Thread | G 1/8 |
| Medium | Compressed air, neutral gases |
| Norm | DIN EN 61076-2-104 |
| Operating conditions | ISO 8573-1 |
| Series | SPAU |
| Protection rating | IP65 |
| Temperaturbereich | 0-50 °C |
| Temperature (max.) | 50 |
Downloads
Accessories
Connecting cable M8x1, 3-pin, 3-wire, socket, angled, open end 2.5 m SIM-M8-3WD-2,5-PSL-PU - Festo 159424
Item FES-159424Pressure sensor for vacuum 0 to -1 bar, 2x PNP/NPN, IO-Link, with display SPAU-V1R-W-Q4D-L-PNLK-PNVBA - Festo 8001238
Item FES-8001238Pressure sensor for vacuum 0 to -1 bar, 2x PNP/NPN, IO-Link, with display SPAU-V1R-F-Q6-L-PNLK-PNVBA-M12 - Festo 8001228
Item FES-8001228Pressure sensor for vacuum 0 to -1 bar, 2x PNP/NPN, IO-Link, with display SPAU-V1R-F-Q4-L-PNLK-PNVBA-M12 - Festo 8001227
Item FES-8001227Pressure sensor for vacuum 0 to -1 bar, 2x PNP/NPN, IO-Link, with display SPAU-V1R-H-G18FD-L-PNLK-PNVBA - Festo 8001223
Item FES-8001223Questions about this item
Any other question?
Send us the item number and your question. We clarify technical details directly with the manufacturer and usually reply on the next working day.




