Images are examples, some edited with AI. The technical data are authoritative. AI notice
S2V series valve terminal, 8 stations 5/2-way, EtherNet/IP, G 1/8 side ports on sub-base - E.MC
This S2V terminal combines 8 valve stations with 5/2-way valves and an EtherNet/IP interface in one unit. G 1/8 working ports on the sub-base side, central G 1/4 supply, rated for -10 to 60 °C.
- Specialist dealer since 2009
- Invoice payment for regular customers
- Worldwide shipping
- Technical questions clarified with the manufacturer
Description
Instead of wiring each solenoid separately, the terminal joins the EtherNet/IP network as a single node. It carries 8 single-solenoid 5/2-way valves with about 700 l/min per station and keeps the overall length to 200.5 mm.
Advantages
- Diagnostics for short circuit, wire break, reverse polarity and under- or overvoltage, with a configurable safe output state on bus failure.
- G 1/8 outlets on the sub-base: hoses stay connected when a valve is replaced.
- Reconfigurable: each station takes a single or double solenoid 5/2-way valve, a 5/3-way valve, a 2x 3/2-way valve or a blanking plate.
- Low heat load in the cabinet at 0.8 W per solenoid, with an LED for every switching state.
- Mounts on a DIN rail or with screws and runs on filtered air without a lubricator.
Applications
- Handling stations and fixtures with eight cylinders supplied from one point.
- Plants with a EtherNet/IP network where the terminal sits on the machine as a separate node.
- Installation in shallow housings or profile frames where hoses are routed out to the side.
Technical data
| Series | E.MC SV, 2 Series (S2V) |
|---|---|
| Valve stations | 8 |
| Fitted valves | 8x 5/2-way, single solenoid, spring return |
| Working ports | 16x G 1/8, side of sub-base |
| Supply | G 1/4, central supply and exhaust |
| Pitch | 16 mm |
| Overall length | 200.5 mm |
| Control | EtherNet/IP |
| Bus connection | 2x M12 socket, 4-pin, D-coded |
| Power connection | M12, 5-pin, A-coded |
| Control voltage | 24 V DC (21.6 to 26.4 V) |
| Bus module current | below 120 mA |
| Power consumption | 0.8 W per solenoid |
| Working pressure | 1.5 to 8 bar (5/2), 2 to 8 bar (5/3 and 2x 3/2) |
| Proof pressure | 12 bar |
| Medium | clean compressed air, 40 µm filtered, no lubrication required |
| Effective area | 16.2 mm² (Cv 0.9) per 5/2-way valve |
| Flow rate | approx. 700 l/min per valve station |
| Response time | max. 20 ms at 5 bar |
| Switching frequency | max. 5 Hz (5/2), max. 3 Hz (5/3) |
| Ambient temperature | -10 to 60 °C |
| Protection class | IP 40 |
| Insulation class | F |
| Materials | body and spool aluminium, seals NBR, pilot plastic |
| Service life | min. 40 million cycles |
| Indicator | LED per solenoid |
| Approval | UL certified |
| Mounting | DIN rail or screws |
| Scope of delivery | valve terminal with fitted valves, DIN rail adapter |
| Dimension drawing | in the E.MC datasheet (PDF) |
| Manufacturer | E.MC |
| Hersteller-Nr | S2V-18-8M-EN |
| EAN | 4070497021167 |
| Zolltarifnummer | 84812090 |
| GPSR Herstellerdaten | A1-ESD equipment GmbH. Keldersstr. 15, DE-42697 Solingen, www.esd.equipment |
| Artikelzustand | New |
| Artikel-Authentizität | Original product |
| Anzahl Stationen [Stk] | 8 |
| Temperaturbereich | -10-60 °C |
Downloads
Questions about this item
Any other question?
Send us the item number and your question. We clarify technical details directly with the manufacturer and usually reply on the next working day.