Images are examples, some edited with AI. The technical data are authoritative. AI notice

S2V series valve terminal, 6 stations 5/2-way, CC-Link, G 1/8 top ports - E.MC

E.MC ✓ Original product Brand new

6 valves, one bus connection: this E.MC terminal sits directly on the CC-Link network and removes point-to-point wiring to every solenoid. Each station delivers about 700 l/min through G 1/8 top ports on the valves.

Net
€1,307.28
excl. VAT
Item FL-816803
Manufacturer no. S2V-18-6-CC
Question about this item
  • Specialist dealer since 2009
  • Invoice payment for regular customers
  • Worldwide shipping
  • Technical questions clarified with the manufacturer

Description

On machines with CC-Link control, this terminal drives up to 6 double-acting cylinders or other actuators. The bus module sits directly on the valve block, power and bus connect via M12 plugs, and each valve draws 0.8 W.

Advantages

  • Mounts on a DIN rail or with screws and runs on filtered air without a lubricator.
  • CC-Link right on the valve block: bus via M12 plug and M12 socket, 5-pin, A-coded, power via M12, 5-pin, A-coded. The bus module draws less than 50 mA.
  • Diagnostics for short circuit, wire break, reverse polarity and under- or overvoltage, with a configurable safe output state on bus failure.
  • G 1/8 outlets directly on the valves, easy to reach from above, 16 mm pitch.
  • Reconfigurable: each station takes a single or double solenoid 5/2-way valve, a 5/3-way valve, a 2x 3/2-way valve or a blanking plate.

Applications

  • Compact assemblies such as grippers, clamping or lifting units with up to 6 double-acting cylinders.
  • Existing CC-Link installations that are extended with additional pneumatic axes.
  • Open DIN rail installation where hoses are plugged in and checked from above.

Technical data

SeriesE.MC SV, 2 Series (S2V)
Valve stations6
Fitted valves6x 5/2-way, single solenoid, spring return
Working ports12x G 1/8, top of valves
SupplyG 1/4, central supply and exhaust
Pitch16 mm
Overall length168.5 mm
ControlCC-Link
Bus connectionM12 plug and M12 socket, 5-pin, A-coded
Power connectionM12, 5-pin, A-coded
Control voltage24 V DC (21.6 to 26.4 V)
Bus module currentbelow 50 mA
Power consumption0.8 W per solenoid
Working pressure1.5 to 8 bar (5/2), 2 to 8 bar (5/3 and 2x 3/2)
Proof pressure12 bar
Mediumclean compressed air, 40 µm filtered, no lubrication required
Effective area16.2 mm² (Cv 0.9) per 5/2-way valve
Flow rateapprox. 700 l/min per valve station
Response timemax. 20 ms at 5 bar
Switching frequencymax. 5 Hz (5/2), max. 3 Hz (5/3)
Ambient temperature-10 to 60 °C
Protection classIP 40
Insulation classF
Materialsbody and spool aluminium, seals NBR, pilot plastic
Service lifemin. 40 million cycles
IndicatorLED per solenoid
ApprovalUL certified
MountingDIN rail or screws
Scope of deliveryvalve terminal with fitted valves, DIN rail adapter
Dimension drawingin the E.MC datasheet (PDF)
ManufacturerE.MC
Hersteller-NrS2V-18-6-CC
EAN4070497021037
Zolltarifnummer84812090
GPSR HerstellerdatenA1-ESD equipment GmbH. Keldersstr. 15, DE-42697 Solingen, www.esd.equipment
ArtikelzustandNew
Artikel-AuthentizitätOriginal product
Anzahl Stationen [Stk]6
Temperaturbereich-10-60 °C

Questions about this item

Any other question?

Send us the item number and your question. We clarify technical details directly with the manufacturer and usually reply on the next working day.

Customers Who Bought This Item Also Bought