Images are examples, some edited with AI. The technical data are authoritative. AI notice
Valve terminal 2 Series, 12x 5/2-way single solenoid, G 1/8 top-ported, IO-Link - E.MC
Decentralised IO-Link valve terminal: 12x spring-return 5/2-way valve and 24 G 1/8 outlets. The bus node reports short circuit, wire break and undervoltage back to the controller.
- Specialist dealer since 2009
- Invoice payment for regular customers
- Worldwide shipping
- Technical questions clarified with the manufacturer
Description
With its integrated IO-Link module, this valve terminal works decentrally, close to the cylinders. 12 single-solenoid 5/2-way valves on a 16 mm pitch switch at 1.5 to 8 bar.
Advantages
- Straight to the IO-Link master: bus connection M12, A-coded, port class B, power via M12, no output card needed in the controller.
- Ports within easy reach: the G 1/8 outlets sit on top of the valves, easy to get at during commissioning.
- High flow per station: effective area 16.2 mm² (Cv 0.9) on a pitch of only 16 mm.
- Reconfigurable: any station can later take a valve with one or two coils, including 5/3-way or 2x 3/2-way functions.
- Long service life: at least 40 million cycles, aluminium body and spool, NBR seals.
Applications
- Multi-axis sequences with up to 12 cylinders supplied centrally from one valve terminal
- Assembly and packaging machines with mid-size cylinders that need more flow per valve
- Decentralised valve terminals right at the machine, connected to a free port of an IO-Link master
- Layouts with little room to the side, where the tubes leave upwards
Accessories
E.MC supplies M12 power cables, matching bus cables and blanking plates for unused stations.
Technical data
| Design | valve terminal, valves on manifold base, integrated wiring |
|---|---|
| Series | E.MC ESV, 2 Series with fieldbus module |
| Valve stations | 12 |
| Fitted valves | 5/2-way, single solenoid, air and spring return |
| Working ports | 24x G 1/8, top-ported on the valves |
| Supply | central, G 1/4 |
| Valve pitch | 16 mm |
| Control | fieldbus IO-Link |
| Bus connection | M12, A-coded, port class B |
| Bus module supply voltage | 24 V DC (21.6 to 26.4 V) |
| Bus module current draw | below 25 mA |
| Operating pressure | 1.5 to 8 bar (5/3-way and 2x 3/2-way: 2 to 8 bar) |
| Proof pressure | 12 bar |
| Medium | clean compressed air, filtered to 40 µm, no lubrication required |
| Ambient temperature | -10 to +50 °C (bus module) |
| Valve voltage | 24 V DC ±10 % |
| Power consumption | 0.8 W per solenoid |
| Insulation class | F |
| Response time | 20 ms or less at 5 bar |
| Max. switching frequency | 5 Hz (5/3-way: 3 Hz) |
| Effective area per station | 16.2 mm² (Cv 0.9) |
| Flow per station | approx. 700 l/min |
| Materials | body and spool aluminium, seals NBR, pilot plastic |
| Service life | at least 40 million cycles |
| Indicator | LED per solenoid |
| Protection class | IP 40 |
| Certification | UL |
| Mounting | DIN rail or screws, DIN adapter included |
| Overall length | 264.5 mm |
| Dimension drawing | in the E.MC datasheet (PDF) |
| Weight | 0.65 kg |
| Manufacturer | E.MC |
| Hersteller-Nr | S2V-18-12-IO |
| EAN | 4050571915674 |
| Zolltarifnummer | 84812090 |
| GPSR Herstellerdaten | A1-ESD equipment GmbH. Keldersstr. 15, DE-42697 Solingen, www.esd.equipment |
| Artikelzustand | New |
| Artikel-Authentizität | Original product |
| Anzahl Stationen [Stk] | 12 |
| Temperaturbereich | -10-50 °C |
Downloads
Questions about this item
Any other question?
Send us the item number and your question. We clarify technical details directly with the manufacturer and usually reply on the next working day.