As soon as a machine has more than a handful of actuators, grouping the valves in one place pays off. This valve terminal holds 10 stations and is controlled through PROFINET. The air supply runs jointly through the manifold and the wiring through a single cable. The supply is 24 V DC. The materials are body and spool aluminium, seals NBR, pilot plastic.
Advantages
- Dimensions A 19, B 16, C 22, D 86, E 94.5, F 102.8, H 4.2, K 187.5, L 179.5, P 11.5, R 25, S 59.5, so the space requirement can be planned in advance.
- Outlets M 5 at valves (top), so the position of the fittings is known in advance.
- Mounted valves: Half-socket valves (5/2-way with spring return), so the terminal is ready for operation.
- Capacity for 10 valve stations, so the terminal grows with the plant.
- Control through PROFINET, which reduces the wiring to a single cable.
Technical data
| Feature | Value |
|---|
| G1 | 20x M 5 |
|---|
| Number of stations [pcs] | 10 |
|---|
| Control | PROFINET |
|---|
| mounted valves | Half-socket valves (5/2-way with spring return) |
|---|
| Temperature range [°C] | -10 to +60 |
|---|
| Outlets | M 5 at valves (top) |
|---|
| G2 | G 1/8" |
|---|
| Dimensions [mm] | A 19, B 16, C 22, D 86, E 94.5, F 102.8, H 4.2, K 187.5, L 179.5, P 11.5, R 25, S 59.5 |
|---|
| Material body and spool | aluminium |
|---|
| Material seals | NBR |
|---|
| Material pilot | plastic |
|---|
| Operating pressure | 1.5 to 8 bar (5/3-way: 2 to 8 bar) |
|---|
| Flow rate | per valve station M 5: approx. 230 l/min, M 7: approx. 330 l/min |
|---|
| Media | oiled and non-oiled, filtered compressed air |
|---|
| Switching time | below 15 ms, max. 5 switching cycles / sec. (5/3-way: max. 3 switching cycles / sec.) |
|---|
| Control voltages | 24 V DC |
|---|
| Voltage tolerance | plus/minus 10 percent |
|---|
| Power consumption | 0.8 W / valve solenoid |
|---|
| Protection class | IP 40 |
|---|
| Service life | min. 40 million switching cycles |
|---|
| Scope of delivery | valve terminal including mounted valves |
|---|
Applications
- Retrofitting and extending existing valve islands.
- Special purpose machinery with a changing number of actuators.
- Machines with up to 10 pneumatic axes in one place.
- Plants whose control is connected through PROFINET.