Images are examples, some edited with AI. The technical data are authoritative. AI notice

Flow sensor 50 to 5000 l/min for compressed air G1 IO-Link SFAM-90-5000L-TG1-PNLK-PNVBA-M12-EMD - Festo 8187370

Festo ✓ Original product Brand new

From 50 up to 5000 l/min, the Festo flow sensor SFAM-90-5000L-TG1-PNLK-PNVBA-M12-EMD records pressure, mass flow, temperature, volume and volumetric flow of compressed air. Limit values are signalled via two switching outputs, PNP or NPN selectable, the measured value via analogue output 0 - 10 V, 4 - 20 mA, 1 - 5 V and IO-Link. Operating pressure 16 bar, connection G1.

Net
€1,127.51
excl. VAT
Item FES-8187370
Manufacturer no. SFAM-90-5000L-TG1-PNLK-PNVBA-M12-EMD
Question about this item
  • Specialist dealer since 2009
  • Invoice payment for regular customers
  • Worldwide shipping
  • Technical questions clarified with the manufacturer

Description

The SFAM-90-5000L-TG1-PNLK-PNVBA-M12-EMD makes pressure, mass flow, temperature, volume and volumetric flow of compressed air visible: measuring range 50 to 5000 l/min, thermal measuring principle.

Benefits

  • Measuring range 50 to 5000 l/min, pressure drop 100 mbar
  • Accuracy ± (3 % of measured value + 0.3 % FS), repetition accuracy zero point ±0.2 %FS, span ±0.8 %FS
  • Measuring principle thermal, method Heat loss
  • Additional temperature measurement 0 to 100 °C
  • Switching output 2 x PNP or 2 x NPN, switchable, analogue output 0 - 10 V, 4 - 20 mA, 1 - 5 V and IO-Link
  • Multi-colour illuminated LCD, units MPa, bar, kPa, kg, kg/min, l, l/min, m3, m3/h, psi, scfm, scft, °C, °F

Applications

Operating medium of the SFAM-90-5000L-TG1-PNLK-PNVBA-M12-EMD: argon, compressed air to ISO 8573-1:2010 [7:4:4], carbon dioxide, nitrogen, flow direction unidirectional, from left to right. Typical tasks up to 5000 l/min include consumption measurement on machines and monitoring the compressed air supply. The SFAM-90-5000L-TG1-PNLK-PNVBA-M12-EMD runs on 15 to 30 V DC.

Technical data

TypeSFAM-90-5000L-TG1-PNLK-PNVBA-M12-EMD
Festo part number8187370
ApprovalRCM, c UL us - Listed (OL)
CE mark (see declaration of conformity)To EU EMC Directive, In accordance with EU RoHS Directive
UKCA marking (see declaration of conformity)To UK RoHS instructions
Certificate issuing authorityUL E322346
Note on materialsRoHS compliant
Measured variablePressure, Mass flow rate, Temperature, Volume, Volumetric flow rate
Flow directionUnidirectional, from left to right
Measuring principleThermal
Measurement methodHeat loss
Start value for pressure measuring range0 bar
End value for pressure measuring range16 bar
Start value for flow rate measuring range50 l/min
End value for flow rate measuring range5000 l/min
Temperature measuring range start value0 °C
Temperature measuring range end value100 °C
Operating pressure16 bar
Overload pressure20 bar
Operating mediumArgon, Compressed air to ISO 8573-1:2010 [7:4:4], Carbon dioxide, Nitrogen
Media temperature0 to 50 °C
Ambient temperature0 to 50 °C
Nominal temperature23 °C
Accuracy of pressure value in ± %FS1.5 %FS
Accuracy of flow rate± (3 % of measured value + 0.3 % FS)
Accuracy temperature in ± °C5 °C
Repetition accuracy of pressure value in ± %FS0.3 %FS
Repetition accuracy offset in ± %FS0.2 %FS
Repetition accuracy span in ± %FS0.8 %FS
Temperature coefficient in ± %FS/K0.05 %FS/K
Temperature coefficient span in ± %FS/Ktyp. 0.1%FS/K
Pressure influence on span in ± %FS/bar0.5 %FS/b.
Switching output2 x PNP or 2 x NPN, switchable
Switching functionWindow comparator or threshold value comparator, adjustable
Switching element functionNC or NO, switchable
Max. output current100 mA
Analogue output0 - 10 V, 4 - 20 mA, 1 - 5 V
Flow characteristic curve start value0 l/min
Flow characteristic curve end value5000 l/min
Temperature characteristic curve start value0 °C
Temperature characteristic curve end value100 °C
Output characteristic curve start value0 V
Output characteristic curve end value10 V
Output characteristic curve start value4 mA
Output characteristic curve end value20 mA
Max. load resistance current output500 Ohm
Min. load resistance voltage output20 kOhm
Short circuit current ratingYes
Overload protectionAvailable
ProtocolIO-Link
IO-Link, revision IDV1.1
IO-Link, device profileFirmware update, Function locator, Function Product URI, Function quantity detection, Identification and diagnostics, Smart Sensor - SSP 4.1.3
IO-Link, transmission rateCOM3
IO-Link, SIO mode supportYes
IO-Link, port typeClass A
IO-Link, process data length output0 bit
IO-Link, process data length input96 bit
IO-Link, process data content INMonitoring the average flow rate 1 bit SSC, Reference record unusable 1 bit, Monitoring the peak flow rate 1 bit SSC, Time monitoring of the active-static operating status 1 bit SSC
IO-Link, service data content INVolume/mass measured value 32 bit, Pneumatic energy measurement 32 bit, Pneumatic power measurement 32 bit
IO-Link, minimum cycle time1.5 ms
IO-Link, data storage required1000 byte
Operational voltage range DC15 to 30 V
Reverse polarity protectionFor all electrical connections
Electrical connection 1, connection typePlug
Electrical connection 1, connector systemM12x1, A-coded to EN 61076-2-101
Electrical connection 1, number of connections/cores5
Electrical connection 1, type of mountingScrew-type lock
Electrical connection 1, compatible type of mountingCompatible with rotatable screw-type lock
Max. cable length20 m with IO-Link operation, 30 M
Type of mountingInline installation
Mounting positionAny
Pneumatic connectionG1
Product weight600 g
Material housingDie-cast aluminium, Reinforced PA
Display typeIlluminated LCD, multi-colour
Displayable unitsMPa, bar, kPa, kg, kg/min, l, l/min, m3, m3/h, psi, scfm, scft, °C, °F
Setting optionsIO-Link, Teach-in, Via display and buttons
Protection against tamperingIO-Link, PIN code
Setting range threshold value0 to 100 %
Setting range hysteresis0 to 90 %
Degree of protectionIP65
Pressure drop100 mbar
Protection classIII
Corrosion resistance class CRC2 - Moderate corrosion stress
LABS (PWIS) conformityVDMA24364-B1/B2-L
Pollution degree3
Weight3.5 kg
ManufacturerFesto
Hersteller-NrSFAM-90-5000L-TG1-PNLK-PNVBA-M12-EMD
EAN4052568629663
Zolltarifnummer90268020
GPSR HerstellerdatenFesto Vertrieb GmbH&Co. KG, Festo Campus 1, DE-73734 Esslingen, festo.com
ArtikelzustandNew
Artikel-AuthentizitätOriginal product
ThreadG 1
Medientemperatur [°C]0 bis 50
SeriesSFAM
Betriebsdruck max [bar]16
Protection ratingIP65
Temperaturbereich0-50 °C