Images are examples, some edited with AI. The technical data are authoritative. AI notice
Electrical fieldbus connection for EB 80 valve island, IO-Link 32 IN / 32 OUT, 12 and 24 V DC, type 02282E0IO - Riegler 150963
This fieldbus connection links the EB 80 valve island to the controller via IO-Link 32 IN / 32 OUT, powers it and handles diagnostics. Up to 32 solenoid controls are possible.
- Specialist dealer since 2009
- Invoice payment for regular customers
- Worldwide shipping
- Technical questions clarified with the manufacturer
Description
One bus line instead of many wires: module 02282E0IO is the electrical connection of an EB 80 island for IO-Link 32 IN / 32 OUT. The system works with 12 and 24 V DC, from 10.8 V DC up to 31.2 V DC. Voltages above 32 V DC will damage the system irreparably.
Advantages
- Fieldbus: IO-Link Version 1.1
- Up to 32 solenoid controls
- Up to 32 digital input signals
- Diagnostics: IO-Link: LED + software info, outputs: LED + state bytes
- Operating voltage 10.8 V DC to 31.2 V DC
- Protection rating IP 65
Applications
Pneumatic controls in machine and plant engineering with a central valve island close to the process.
Technical data
| Type no. | 02282E0IO |
|---|---|
| Seal material | NBR |
| Duty cycle | 100 % |
| Version | IO-Link 32 IN / 32 OUT |
| Supply voltage range | 12 -10 % to 24 +30 % V DC |
| Operating voltage | 10.8 to 31.2 V DC |
| Maximum admissible voltage | 32 V DC |
| Ambient temperature | -10 to 50 °C |
| Housing | technopolymer / painted aluminium |
| Module type | E |
| Module description | electrical connection with fieldbus |
| Protection | module: overload, polarity inversion, output: overload, SC |
| Diagnostics | IO-Link: LED + software info, outputs: LED + state bytes |
| Diagnostic signals | SC, coil fail., UV/OV, mod. com., switch state, dev. config. |
| Power consumption without valve control | 4 W for module electr. conn.-E + 0.25 W per Base-B |
| Solenoid pilot power on start-up (speed up) | 3 W for 15 ms |
| Maximum number of simultaneous solenoid controls on activation | 38 (greater number possible with intermediate module - M) |
| Fieldbus | IO-Link Version 1.1 |
| Communication speed | 230.4 Kbps (COM3) |
| Vendor ID / Device ID | 1046 (hex 0x0416) / 32 (hex 0x000020) |
| Process data length | 5 byte of input / 4 byte of output |
| Maximum number of solenoid controls | 32 |
| Maximum admissible current for valve supply, continuous | 4 A |
| Maximum admissible current for valve supply, instantaneous | 6 A |
| Maximum admissible current for bus/signal supply, continuous | 4 A |
| Maximum admissible current for bus/signal supply, instantaneous | 6 A |
| Maximum number of digital input signals | 32 |
| Power input | max. 3.15 W |
| Protection rating | IP 65 |
| Series | EB 80 |
| Weight | 0.46 kg |
| Manufacturer | Riegler |
| Hersteller-Nr | 02282E0IO |
| EAN | 4047322814393 |
| Zolltarifnummer | 84818099 |
| GPSR Herstellerdaten | Riegler & Co. KG, Schützenstraße 27, DE-72574 Bad Urach, www.riegler.de |
| Artikelzustand | New |
| Artikel-Authentizität | Original product |
| Country of Manufacture | Italy |
| Ausführung | IO-Link 32 IN / 32 OUT |
| Material | Technopolymer / aluminium, painted |
| Housing material | Technopolymer / aluminium, painted |
| Temperaturbereich | -10-50 °C |
| Temperature (max.) | 50 |
Downloads