Controller for CPX-E, EtherCAT, EtherCAT CoE protocol, 24 V DC, IP20 CPX-E-CEC-C1 - Festo 5226780
The controller CPX-E-CEC-C1 is a genuine Festo part for the CPX-E system. Festo specifies EtherCAT, EtherCAT CoE protocol, nominal operating voltage 24 V DC and power failure bridging 20 ms. Further data: transmission rate 100 Mbit/s and IP20 protection.
- Specialist dealer since 2009
- Invoice payment for regular customers
- Worldwide shipping
- Technical questions clarified with the manufacturer
Description
The controller CPX-E-CEC-C1 is a genuine Festo part for the CPX-E system. The main data are EtherCAT, EtherCAT CoE protocol and nominal operating voltage 24 V DC.
Advantages
- Fieldbus connection via EtherCAT, EtherCAT CoE
- Nominal operating voltage 24 V DC
- Power failure bridging 20 ms
- Transmission rate 100 Mbit/s
- IP20 degree of protection
- Suitable for ambient temperatures of -5 to 50 °C
Application
CPX-E-CEC-C1 is used when designing, extending and maintaining installations with the CPX-E system.
Technical data
| Type | CPX-E-CEC-C1 |
|---|---|
| Festo part number | 5226780 |
| Dimensions (W x L x H) | 42.2 mm x 76.5 mm x 125.8 mm |
| Grid dimension | 18.9 mm |
| Type of mounting | via DIN rail |
| Max. number of modules | 10 |
| Product weight | 145 g |
| Mounting position | Vertical, Horizontal |
| Ambient temperature | -5 to 50 °C |
| Note on ambient temperature | -5 - 60°C for vertical installation |
| Storage temperature | -20 to 70 °C |
| Relative air humidity | 95%, Non-condensing |
| Degree of protection | IP20 |
| Corrosion resistance class CRC | 0 - No corrosion stress |
| Vibration resistance | Transport application test with severity level 1 to FN 942017-4 and EN 60068-2-6 |
| Shock resistance | Shock test with severity level 1 to FN 942017-5 and EN 60068-2-27 |
| Protection against direct and indirect contact | PELV |
| LABS (PWIS) conformity | VDMA24364 zone III |
| CE mark (see declaration of conformity) | To EU EMC Directive, In accordance with EU RoHS Directive |
| UKCA marking (see declaration of conformity) | To UK RoHS instructions |
| KC mark | KC-EMV |
| Approval | RCM, c UL us - Listed (Oil) |
| Certificate issuing authority | UL E239998 |
| Note on materials | RoHS compliant |
| Material housing | PA |
| Diagnostics via LED | Force mode, Module status, Network status, engineering port 1, Network status EtherCAT, Run, Power supply, electronics/sensors, Load power supply, System errors |
| Operator controls | DIP switch for RUN/STOP |
| IP address setting | DHCP, Via CODESYS |
| Fieldbus interface | Ethernet |
| Field bus, protocol | EtherCAT, EtherCAT CoE, EtherCAT EoE, EtherCAT FoE, EtherCAT master |
| Fieldbus interface, function | Bus connection continuing |
| Field bus, connection type | Socket |
| Field bus, connection system | RJ45 |
| Field bus, connection pattern | 8 |
| Field bus interface, electrical isolation | Yes |
| Field bus interface, transmission rate | 100 Mbit/s |
| Ethernet interface, connection type | Socket |
| Ethernet interface, protocol | EasyIP, Modbus TCP, OPC-UA, TCP/IP |
| Ethernet interface, function | Diagnostics |
| Ethernet interface, connection system | RJ45 |
| Ethernet interface, number of pins/wires | 8 |
| Ethernet interface, transmission rate | 10 Mbit/s, 100 Mbit/s |
| Max. address volume, inputs | 64 byte |
| Max. address volume, outputs | 64 byte |
| System parameters | Diagnostic memory, Fail-safe response, System start |
| Module parameters | Channel alarms for undervoltage, Process value representation of analogue modules |
| Configuration support | CODESYS V3 |
| Additional functions | CODESYS V3 |
| CPU data | Dual core 650 MHz |
| Power supply, function | Electronic system and sensors |
| Power supply, connection type | Terminal strip |
| Power supply, note on connection type | > 4 A and UL 2x terminal strip for power supply |
| Power supply, connection system | Spring-loaded terminal |
| Power supply, number of pins/wires | 4 |
| Nominal DC operating voltage, electronics/sensors | 24 V |
| Permissible voltage fluctuations for electronics/sensors | ± 25 % |
| Power supply, conductor diameter | 0.2 to 1.5 mm² |
| Power supply, note on conductor diameter | 0.2 - 2.5 mm² for flexible conductors without wire ferrule |
| Max. power supply | 8 A |
| Intrinsic current consumption at nominal operating voltage for electronics/sensors | Typically 65 mA |
| Power failure bridging | 20 ms |
| Reverse polarity protection | 24 V sensor supply against 0 V sensor supply |
| Programming software | CODESYS provided by Festo |
| Program memory | 12 MB user program |
| Processing time | Approx. 200 µs/1 k instruction |
| Function modules | And others, Read CPX-E module diagnostics, CPX-E diagnostic status, Copy CPX-E diagnostic trace |
| Buffering time real-time clock | 3 Wochen |
| Flag | 120 kB remanent data, CODESYS variable concept |
| Weight | 0.185 kg |
| Manufacturer | Festo |
| Hersteller-Nr | CPX-E-CEC-C1 |
| EAN | 4052568421458 |
| Zolltarifnummer | 85371091 |
| GPSR Herstellerdaten | Festo Vertrieb GmbH&Co. KG, Festo Campus 1, DE-73734 Esslingen, festo.com |
| Artikelzustand | New |
| Artikel-Authentizität | Original product |
| Housing material | PA |
| Operating voltage | 24 V DC |
| Protection rating | IP20 |
| Temperature (max.) | 50 |