Images are examples, some edited with AI. The technical data are authoritative. AI notice

IO-Link master for CPX-AP-I, IO-Link protocol, 4 IO-Link ports, 24 V DC CPX-AP-I-4IOL-M12 - Festo 8086604

Festo ✓ Original product Brand new

The IO-Link master CPX-AP-I-4IOL-M12 connects IO-Link devices to the CPX-AP-I system. The data sheet lists IO-Link protocol, 4 IO-Link ports and nominal operating voltage 24 V DC. Further data: power failure bridging 10 ms and reverse polarity protection.

Net
€302.96
excl. VAT
Item FES-8086604
Manufacturer no. CPX-AP-I-4IOL-M12
Question about this item
  • Specialist dealer since 2009
  • Invoice payment for regular customers
  • Worldwide shipping
  • Technical questions clarified with the manufacturer

Description

The IO-Link master CPX-AP-I-4IOL-M12 connects IO-Link devices to the CPX-AP-I system. For system design, the relevant data are IO-Link protocol and 4 IO-Link ports.

Advantages

  • Fieldbus connection via IO-Link
  • 4 IO-Link ports for sensors and actuators
  • Nominal operating voltage 24 V DC
  • Power failure bridging 10 ms
  • Integrated reverse polarity protection
  • IP65/IP67 protection for mounting directly on the machine

Application

CPX-AP-I-4IOL-M12 is used to build and extend automation solutions based on the CPX-AP-I system.

Technical data

TypeCPX-AP-I-4IOL-M12
Festo part number8086604
ProtocolIO-Link
Dimensions (W x L x H)30 mm x 170 mm x 35 mm
Type of mountingOn DIN rail via accessories, With through-hole
Product weight126 g
Ambient temperature-20 to 60 °C
Storage temperature-40 to 70 °C
Relative air humidity5 - 95%, Non-condensing
Degree of protectionIP65, IP67
Note on degree of protectionUnused connections sealed
Corrosion resistance class CRC1 - Low corrosion stress
Vibration resistanceTransport application test with severity level 1 to FN 942017-4 and EN 60068-2-6
Shock resistanceShock test with severity level 1 to FN 942017-5 and EN 60068-2-27
Pollution degree2
Overvoltage categoryII
Max. cable length50 m system communication
LABS (PWIS) conformityVDMA24364-B2-L
Cleanroom suitability, measured according to ISO 14644-14Element installed statically, no meaningful evaluation possible according to ISO 14644-1
CE mark (see declaration of conformity)To EU EMC Directive, In accordance with EU RoHS Directive
UKCA marking (see declaration of conformity)To UK instructions for EMC, To UK RoHS instructions
KC markKC-EMV
ApprovalRCM, c UL us - Listed (Oil)
Certificate issuing authorityUL E239998
Note on materialsRoHS compliant
Material housingMakrolon, Nickel-plated die-cast zinc
Material o-ringFluoro rubber
Diagnostics via LEDDiagnostics per channel, Diagnostics per module, Load power supply, Status per channel, Status per module
Diagnostics per internal communicationIO-Link event, Short circuit/overload in sensor supply, Electronics/sensors overvoltage, Load overvoltage, Electronics/sensors undervoltage, Load undervoltage
Communication interface, functionSystem communication XF10 IN / XF20 OUT
Communication interface, connection type2x socket
Communication interface, connection technologyM8x1, D-coded according to EN 61076-2-114
Communication interface, number of pins/cores4
Communication interface, protocolAP
Communication interface, screenedYes
Power supply, functionIncoming electronics/sensors and load
Power supply, connection typePlug
Power supply, connection systemM8x1, A-coded to EN 61076-2-104
Power supply, number of pins/wires4
Power transmission, functionOutgoing electronics/sensors and load
Power transmission, connection typeSocket
Power transmission, connection technologyM8x1, A-coded to EN 61076-2-104
Power transmission, number of pins/wires4
Note regarding operating voltageSELV/PELV fixed power supplies required, Note the voltage drop
Nominal operating voltage DC of load24 V
Permissible voltage fluctuation of load± 25 %
Nominal DC operating voltage, electronics/sensors24 V
Permissible voltage fluctuations for electronics/sensors± 25 %
Max. power supply2 x 4 A (external fuse required)
Intrinsic current consumption at nominal operating voltage for electronics/sensorsTypically 55 mA
Intrinsic current consumption at nominal operating voltage loadTypically 5 mA
Power failure bridging10 ms
Reverse polarity protectionYes
Max. residual current of inputs per module2 A
Max. residual current outputs per module4 A
Electrical connection for IO-Link, connection type4x socket
Electrical connection for IO-Link, connection technologyM12x1, A-coded to EN 61076-2-101
Electrical connection for IO-Link, number of pins/wires5
IO-Link, communicationC/Q LED green
IO-Link, Number of ports4
IO-Link, Port classB
IO-Link, Protocol versionMaster V 1.1
IO-Link, communication modeDI, COM1. COM2. COM3., Configurable via software
IO-Link, Process data length OUTCan be parameterised 8 - 128 bytes
IO-Link, Process data length INCan be parameterised 12 - 132 bytes
IO-Link, Min. cycle timeDependent on minimum supported cycle time of the connected IO-Link device
Weight0.145 kg
ManufacturerFesto
Hersteller-NrCPX-AP-I-4IOL-M12
EAN4052568465674
Zolltarifnummer85389099
GPSR HerstellerdatenFesto Vertrieb GmbH&Co. KG, Festo Campus 1, DE-73734 Esslingen, festo.com
ArtikelzustandNew
Artikel-AuthentizitätOriginal product
Operating voltage24 V DC
Protection ratingIP65
Temperaturbereich-20-60 °C
Temperature (max.)60

Downloads

Questions about this item

Any other question?

Send us the item number and your question. We clarify technical details directly with the manufacturer and usually reply on the next working day.

Customers Who Bought This Item Also Bought