Images are examples, some edited with AI. The technical data are authoritative. AI notice
Flow sensor 50 to 5000 l/min for compressed air G1 SFAM-90-5000L-TG1-2SA-M12 - Festo 573352
The flow sensor SFAM-90-5000L-TG1-2SA-M12 is designed for flow rate and consumption of compressed air between 50 l/min and 5000 l/min. Limit values are signalled via two switching outputs, PNP or NPN selectable, the measured value via analogue output 4 - 20 mA. Operating pressure 0 to 16 bar, connection G1.
- Specialist dealer since 2009
- Invoice payment for regular customers
- Worldwide shipping
- Technical questions clarified with the manufacturer
Description
With the Festo SFAM-90-5000L-TG1-2SA-M12 you record flow rate and consumption within 50 to 5000 l/min and evaluate the values on the device or in the controller.
Benefits
- Measuring range 50 to 5000 l/min, pressure drop below 100 mbar
- Accuracy ± (3 % of measured value + 0.3 % FS), repetition accuracy zero point ±0.2 %FS, span ±0.8 %FS
- Measuring principle thermal
- Switching output 2x PNP or 2x NPN, adjustable and analogue output 4 - 20 mA
- blue illuminated LCD, units l, l/min, m3, scf, scfm
- Operating pressure 0 to 16 bar, degree of protection IP65
Applications
Operating medium of the SFAM-90-5000L-TG1-2SA-M12: compressed air to ISO 8573-1:2010 [7:4:4], nitrogen, flow direction unidirectional, from left to right. Typical tasks up to 5000 l/min include consumption measurement on machines and monitoring the compressed air supply. The SFAM-90-5000L-TG1-2SA-M12 runs on 15 to 30 V DC.
Technical data
| Type | SFAM-90-5000L-TG1-2SA-M12 |
|---|---|
| Festo part number | 573352 |
| Approval | RCM, c UL us - Recognized (OL) |
| CE mark (see declaration of conformity) | To EU EMC Directive, to EU RoHS Directive |
| KC mark | KC-EMV |
| Certificate issuing authority | UL E322346 |
| Note on materials | RoHS compliant |
| Measured variable | Flow, consumption |
| Flow direction | Unidirectional, from left to right |
| Measuring principle | Thermal |
| Start value for flow rate measuring range | 50 l/min |
| End value for flow rate measuring range | 5000 l/min |
| Operating pressure | 0 to 16 bar |
| Operating medium | Compressed air to ISO 8573-1:2010 [7:4:4], Nitrogen |
| Media temperature | 0 to 50 °C |
| Ambient temperature | 0 to 50 °C |
| Nominal temperature | 23 °C |
| Accuracy of flow rate | ± (3 % of measured value + 0.3 % FS) |
| Repetition accuracy offset in ± %FS | 0.2 %FS |
| Repetition accuracy span in ± %FS | 0.8 %FS |
| Temperature coefficient span in ± %FS/K | typ. 0.1%FS/K |
| Pressure dependency of span in ± %FS/bar | 0.5 %FS/bar |
| Switching output | 2x PNP or 2x NPN, adjustable |
| Switching function | Window comparator or threshold value comparator, adjustable |
| Switching element function | N/C contact, N/O contact |
| Max. output current | 100 mA |
| Analogue output | 4 - 20 mA |
| Flow characteristic curve start value | 0 l/min |
| Flow characteristic curve end value | 5000 l/min |
| Output characteristic curve start value | 4 mA |
| Output characteristic curve end value | 20 mA |
| Max. load resistance current output | 500 Ohm |
| Short circuit current rating | Yes |
| Operational voltage range DC | 15 to 30 V |
| Reverse polarity protection | For all electrical connections |
| Electrical connection | M12x1, 5-pin, Straight plug |
| Type of mounting | Inline installation |
| Mounting position | Horizontal |
| Pneumatic connection | G1 |
| Product weight | 2400 g |
| Material housing | Die-cast aluminium, Reinforced PA |
| Display type | Backlit blue LCD |
| Displayable units | l, l/min, m3, scf, scfm |
| Degree of protection | IP65 |
| Pressure drop | below 100 mbar |
| Corrosion resistance class CRC | 2 - Moderate corrosion stress |
| Weight | 3.5 kg |
| Manufacturer | Festo |
| Hersteller-Nr | SFAM-90-5000L-TG1-2SA-M12 |
| EAN | 4052568219833 |
| Zolltarifnummer | 90268020 |
| GPSR Herstellerdaten | Festo Vertrieb GmbH&Co. KG, Festo Campus 1, DE-73734 Esslingen, festo.com |
| Artikelzustand | New |
| Artikel-Authentizität | Original product |
| Material | Aluminium |
| Thread | G 1 |
| Medium | Compressed air, neutral gases |
| Medientemperatur [°C] | 0 bis 50 |
| Operating conditions | ISO 8573-1 |
| Series | SFAM |
| Betriebsdruck max [bar] | 16 |
| Protection rating | IP65 |
| Temperaturbereich | 0-50 °C |
| Temperature (max.) | 50 |
Downloads
Accessories
Connecting cable M8x1, 3-pin, 3-wire, socket, angled, open end 2.5 m SIM-M8-3WD-2,5-PSL-PU - Festo 159424
Item FES-159424Flow sensor 50 to 5000 l/min for compressed air G1 SFAM-90-5000L-TG1-2SV-M12 - Festo 573353
Item FES-573353Flow sensor 50 to 5000 l/min for compressed air SFAM-90-5000L-M-2SV-M12 - Festo 573347
Item FES-573347Flow sensor 50 to 5000 l/min for compressed air SFAM-90-5000L-M-2SA-M12 - Festo 573346
Item FES-573346Flow sensor 150 to 15000 l/min for compressed air SFAM-90-15000L-M-2SV-M12 - Festo 573351
Item FES-573351Flow sensor 100 to 10000 l/min for compressed air G1 1/2 SFAM-90-10000L-TG112-2SA-M12 - Festo 573354
Item FES-573354Flow sensor 150 to 15000 l/min for compressed air SFAM-90-15000L-M-2SA-M12 - Festo 573350
Item FES-573350Questions about this item
Any other question?
Send us the item number and your question. We clarify technical details directly with the manufacturer and usually reply on the next working day.