Images are examples, some edited with AI. The technical data are authoritative. AI notice

Flow sensor 10 to 1000 l/min for compressed air SFAM-62-1000L-M-2SV-M12 - Festo 564932

Festo ✓ Original product Brand new

The flow sensor SFAM-62-1000L-M-2SV-M12 measures flow rate and consumption of compressed air within 10 to 1000 l/min. For limit values up to 1000 l/min there are two switching outputs, PNP or NPN selectable, the measured value is output via analogue output 0 - 10 V. Permitted operating pressure 0 to 16 bar.

Net
€914.79
excl. VAT
Item FES-564932
Manufacturer no. SFAM-62-1000L-M-2SV-M12
Question about this item
  • Specialist dealer since 2009
  • Invoice payment for regular customers
  • Worldwide shipping
  • Technical questions clarified with the manufacturer

Description

The SFAM-62-1000L-M-2SV-M12 makes flow rate and consumption of compressed air visible: measuring range 10 to 1000 l/min, thermal measuring principle.

Benefits

  • Measuring range 10 to 1000 l/min, pressure drop below 100 mbar
  • Accuracy ± (3 % of measured value + 0.3 % FS), repetition accuracy zero point ±0.2 %FS, span ±0.8 %FS
  • Measuring principle thermal
  • Switching output 2x PNP or 2x NPN, adjustable and analogue output 0 - 10 V
  • blue illuminated LCD, units l, l/min, m3, scf, scfm
  • Operating pressure 0 to 16 bar, degree of protection IP65

Applications

Operating medium of the SFAM-62-1000L-M-2SV-M12: compressed air to ISO 8573-1:2010 [7:4:4], nitrogen, flow direction unidirectional, from left to right. Typical tasks up to 1000 l/min include consumption measurement on machines and monitoring the compressed air supply. The SFAM-62-1000L-M-2SV-M12 runs on 15 to 30 V DC.

Technical data

TypeSFAM-62-1000L-M-2SV-M12
Festo part number564932
ApprovalRCM, c UL us - Recognized (OL)
CE mark (see declaration of conformity)To EU EMC Directive, to EU RoHS Directive
KC markKC-EMV
Certificate issuing authorityUL E322346
Note on materialsRoHS compliant
Measured variableFlow, consumption
Flow directionUnidirectional, from left to right
Measuring principleThermal
Start value for flow rate measuring range10 l/min
End value for flow rate measuring range1000 l/min
Operating pressure0 to 16 bar
Operating mediumCompressed air to ISO 8573-1:2010 [7:4:4], Nitrogen
Media temperature0 to 50 °C
Ambient temperature0 to 50 °C
Nominal temperature23 °C
Accuracy of flow rate± (3 % of measured value + 0.3 % FS)
Repetition accuracy offset in ± %FS0.2 %FS
Repetition accuracy span in ± %FS0.8 %FS
Temperature coefficient span in ± %FS/Ktyp. 0.1%FS/K
Pressure dependency of span in ± %FS/bar0.5 %FS/bar
Switching output2x PNP or 2x NPN, adjustable
Switching functionWindow comparator or threshold value comparator, adjustable
Switching element functionN/C contact, N/O contact
Max. output current100 mA
Analogue output0 - 10 V
Flow characteristic curve start value0 l/min
Flow characteristic curve end value1000 l/min
Output characteristic curve start value0 mA
Output characteristic curve end value10 mA
Short circuit current ratingYes
Operational voltage range DC15 to 30 V
Reverse polarity protectionFor all electrical connections
Electrical connectionM12x1, 5-pin, Straight plug
Type of mountingOn service unit
Mounting positionHorizontal
Pneumatic connectionManifold module
Product weight600 g
Material housingDie-cast aluminium, Reinforced PA
Display typeBacklit blue LCD
Displayable unitsl, l/min, m3, scf, scfm
Degree of protectionIP65
Pressure dropbelow 100 mbar
Corrosion resistance class CRC2 - Moderate corrosion stress
Min. load resistance voltage output10 kOhm
Weight0.65 kg
ManufacturerFesto
Hersteller-NrSFAM-62-1000L-M-2SV-M12
EAN4052568211967
Zolltarifnummer90268020
GPSR HerstellerdatenFesto Vertrieb GmbH&Co. KG, Festo Campus 1, DE-73734 Esslingen, festo.com
ArtikelzustandNew
Artikel-AuthentizitätOriginal product
MaterialAluminium
MediumCompressed air, neutral gases
Medientemperatur [°C]0 bis 50
Operating conditionsISO 8573-1
SeriesSFAM
Betriebsdruck max [bar]16
Protection ratingIP65
Temperaturbereich0-50 °C
Temperature (max.)50

Downloads

Accessories

Questions about this item

Any other question?