Images are examples, some edited with AI. The technical data are authoritative. AI notice

Flow sensor 1 to 50 l/min for compressed air 8 mm tubing IO-Link SFAH-50U-Q8S-PNLK-PNVBA-L1 - Festo 8058471

Festo ✓ Original product Brand new

The flow sensor SFAH-50U-Q8S-PNLK-PNVBA-L1 measures mass flow and volumetric flow of compressed air within 1 to 50 l/min. Outputs of the SFAH: two switching outputs, PNP or NPN selectable, plus analogue output 0 - 10 V, 4 - 20 mA, 1 - 5 V and IO-Link. Operating pressure -0.9 to 10 bar, connection for 8 mm tubing.

Net
€273.79
excl. VAT
Item FES-8058471
Manufacturer no. SFAH-50U-Q8S-PNLK-PNVBA-L1
Question about this item
  • Specialist dealer since 2009
  • Invoice payment for regular customers
  • Worldwide shipping
  • Technical questions clarified with the manufacturer

Description

With the Festo SFAH-50U-Q8S-PNLK-PNVBA-L1 you record mass flow and volumetric flow within 1 to 50 l/min and evaluate the values on the device or in the controller.

Benefits

  • Measuring range 1 to 50 l/min, pressure drop 12 mbar
  • Accuracy ± (2 % vom Messwert + 1 % FS), repetition accuracy zero point ±0.2 %FS, span ±0.8 %FS
  • Measuring principle thermal, method Heat transfer
  • Switching output 2 x PNP or 2 x NPN, switchable, analogue output 0 - 10 V, 4 - 20 mA, 1 - 5 V and IO-Link
  • Multi-colour illuminated LCD, units g, g/min, l, l/min, scft, scft/h, scft/min
  • Operating pressure -0.9 to 10 bar, degree of protection IP40

Applications

Operating medium of the SFAH-50U-Q8S-PNLK-PNVBA-L1: compressed air to ISO 8573-1:2010 [6:4:4], nitrogen, argon, flow direction unidirectional. Typical tasks up to 50 l/min include flow monitoring on compressed air consumers and in test rigs. The SFAH-50U-Q8S-PNLK-PNVBA-L1 runs on 22 to 26 V DC.

Technical data

TypeSFAH-50U-Q8S-PNLK-PNVBA-L1
Festo part number8058471
ApprovalRCM, c UL us - Listed (OL)
CE mark (see declaration of conformity)To EU EMC Directive, to EU RoHS Directive
KC markKC-EMV
Certificate issuing authorityUL E322346
Note on materialsRoHS compliant
Measured variableMass flow rate, Volumetric flow rate
Flow directionUnidirectional
Measuring principleThermal
Measurement methodHeat transfer
Start value for flow rate measuring range1 l/min
End value for flow rate measuring range50 l/min
Operating pressure-0.9 to 10 bar
Operating mediumCompressed air to ISO 8573-1:2010 [6:4:4], Nitrogen, Argon
Media temperature0 to 50 °C
Ambient temperature0 to 50 °C
Nominal temperature23 °C
Accuracy of flow rate± (2 % vom Messwert + 1 % FS)
Repetition accuracy offset in ± %FS0.2 %FS
Repetition accuracy span in ± %FS0.8 %FS
Temperature coefficient span in ± %FS/Ktyp. 0.15%FS/K
Pressure dependency of span in ± %FS/bar1 %FS/bar
Switching output2 x PNP or 2 x NPN, switchable
Switching functionWindow comparator, Threshold value comparator, Auto difference monitoring
Switching element functionNC or NO, switchable
Max. output current100 mA
Analogue output0 - 10 V, 4 - 20 mA, 1 - 5 V
Flow characteristic curve start value0 l/min
Flow characteristic curve end value50 l/min
Max. load resistance current output500 Ohm
Min. load resistance voltage output20 kOhm
Short circuit current ratingYes
Overload protectionAvailable
ProtocolIO-Link
IO-Link, protocol versionDevice V 1.1
IO-Link, profileSmart sensor profile
IO-Link, function classesTeach channel, Diagnostics, Identification, Binary data channel (BDC), Process data variable (PDV)
IO-Link, communication modeCOM2 (38.4 kBaud)
IO-Link, SIO mode supportYes
IO-Link, port typeA
IO-Link, process data width IN3 bytes
IO-Link, process data content IN1 bit BDC (volume monitoring), 14 bit PDV (measured flow value), 2 bit BDC (flow monitoring)
IO-Link, service data content IN32-bit volume / mass measured value
IO-Link, minimum cycle time4 ms
IO-Link, data storage requiredbelow 0.5 kB
Operational voltage range DC22 to 26 V
No-load supply currentmax. 25 mA
Reverse polarity protectionFor all electrical connections
Electrical connection 1, connection typePlug
Electrical connection 1, connector systemPlug pattern L1J
Electrical connection 1, number of connections/cores4
Type of mountingWith accessories
Mounting positionAny
Pneumatic connectionFor tubing O.D. 8 mm
Pneumatic connection, outlet directionStraight
Product weight60 g
Material housingReinforced PA
Material in contact with the mediumNBR, High-alloy stainless steel, Reinforced PA, Wrought aluminium alloy, anodised, Epoxy resin, Silicon, Silicon nitride
Display typeIlluminated LCD, multi-colour
Displayable unitsg, g/min, l, l/min, scft, scft/h, scft/min
Setting optionsIO-Link, Teach-in, Via display and buttons
Protection against tamperingIO-Link, PIN code
Degree of protectionIP40
Pressure drop12 mbar
Protection classIII
Corrosion resistance class CRC2 - Moderate corrosion stress
Weight0.11 kg
ManufacturerFesto
Hersteller-NrSFAH-50U-Q8S-PNLK-PNVBA-L1
EAN4052568295530
Zolltarifnummer90268020
GPSR HerstellerdatenFesto Vertrieb GmbH&Co. KG, Festo Campus 1, DE-73734 Esslingen, festo.com
ArtikelzustandNew
Artikel-AuthentizitätOriginal product
MaterialPolyamide (PA)
MediumCompressed air, neutral gases
Medientemperatur [°C]0 bis 50
Operating conditionsISO 8573-1
Operating voltage22-26 V
SeriesSFAH
Betriebsdruck max [bar]10
Protection ratingIP40
Temperaturbereich0-50 °C
Temperature (max.)50

Downloads

Accessories

Questions about this item

Any other question?

Send us the item number and your question. We clarify technical details directly with the manufacturer and usually reply on the next working day.