Images are examples, some edited with AI. The technical data are authoritative. AI notice
Flow sensor 0.002 to 0.1 l/min for compressed air 4 mm tubing IO-Link SFAH-0.1U-Q4S-PNLK-PNVBA-L1 - Festo 8058461
From 0.002 up to 0.1 l/min, the Festo flow sensor SFAH-0.1U-Q4S-PNLK-PNVBA-L1 records mass flow and volumetric flow of compressed air. For limit values up to 0.1 l/min there are two switching outputs, PNP or NPN selectable, the measured value is output via analogue output 4 - 20 mA, 1 - 5 V, 0 - 10 V and IO-Link. Operating pressure -0.9 to 10 bar, connection for 4 mm tubing.
- Specialist dealer since 2009
- Invoice payment for regular customers
- Worldwide shipping
- Technical questions clarified with the manufacturer
Description
With the Festo SFAH-0.1U-Q4S-PNLK-PNVBA-L1 you record mass flow and volumetric flow within 0.002 to 0.1 l/min and evaluate the values on the device or in the controller.
Benefits
- Measuring range 0.002 to 0.1 l/min, pressure drop below 5 mbar
- Accuracy ± (2 % vom Messwert + 1 % FS), repetition accuracy zero point ±0.2 %FS, span ±0.8 %FS
- Measuring principle thermal, method Heat transfer
- Switching output 2 x PNP or 2 x NPN, switchable, analogue output 4 - 20 mA, 1 - 5 V, 0 - 10 V and IO-Link
- Multi-colour illuminated LCD, units g, g/min, l, l/h, l/min, scft, scft/h
- Operating pressure -0.9 to 10 bar, degree of protection IP40
Applications
Operating medium of the SFAH-0.1U-Q4S-PNLK-PNVBA-L1: compressed air to ISO 8573-1:2010 [6:4:4], nitrogen, argon, flow direction unidirectional. Typical tasks up to 0.1 l/min include flow monitoring on compressed air consumers and in test rigs. The SFAH-0.1U-Q4S-PNLK-PNVBA-L1 runs on 22 to 26 V DC.
Technical data
| Type | SFAH-0.1U-Q4S-PNLK-PNVBA-L1 |
|---|---|
| Festo part number | 8058461 |
| Approval | RCM, c UL us - Listed (OL) |
| CE mark (see declaration of conformity) | To EU EMC Directive, to EU RoHS Directive |
| KC mark | KC-EMV |
| Certificate issuing authority | UL E322346 |
| Note on materials | RoHS compliant |
| Measured variable | Mass flow rate, Volumetric flow rate |
| Flow direction | Unidirectional |
| Measuring principle | Thermal |
| Measurement method | Heat transfer |
| Start value for flow rate measuring range | 0.002 l/min |
| End value for flow rate measuring range | 0.1 l/min |
| Operating pressure | -0.9 to 10 bar |
| Operating medium | Compressed air to ISO 8573-1:2010 [6:4:4], Nitrogen, Argon |
| Media temperature | 0 to 50 °C |
| Ambient temperature | 0 to 50 °C |
| Nominal temperature | 23 °C |
| Accuracy of flow rate | ± (2 % vom Messwert + 1 % FS) |
| Repetition accuracy offset in ± %FS | 0.2 %FS |
| Repetition accuracy span in ± %FS | 0.8 %FS |
| Temperature coefficient span in ± %FS/K | typ. 0.15%FS/K |
| Pressure dependency of span in ± %FS/bar | 1 %FS/bar |
| Switching output | 2 x PNP or 2 x NPN, switchable |
| Switching function | Window comparator, Threshold value comparator, Auto difference monitoring |
| Switching element function | NC or NO, switchable |
| Max. output current | 100 mA |
| Analogue output | 4 - 20 mA, 1 - 5 V, 0 - 10 V |
| Flow characteristic curve start value | 0 l/min |
| Flow characteristic curve end value | 0.1 l/min |
| Max. load resistance current output | 500 Ohm |
| Min. load resistance voltage output | 20 kOhm |
| Short circuit current rating | Yes |
| Overload protection | Available |
| Protocol | IO-Link |
| IO-Link, protocol version | Device V 1.1 |
| IO-Link, profile | Smart sensor profile |
| IO-Link, function classes | Teach channel, Diagnostics, Identification, Binary data channel (BDC), Process data variable (PDV) |
| IO-Link, communication mode | COM2 (38.4 kBaud) |
| IO-Link, SIO mode support | Yes |
| IO-Link, port type | A |
| IO-Link, process data width IN | 3 bytes |
| IO-Link, process data content IN | 1 bit BDC (volume monitoring), 14 bit PDV (measured flow value), 2 bit BDC (flow monitoring) |
| IO-Link, service data content IN | 32-bit volume / mass measured value |
| IO-Link, minimum cycle time | 4 ms |
| IO-Link, data storage required | below 0.5 kB |
| Operational voltage range DC | 22 to 26 V |
| No-load supply current | max. 25 mA |
| Reverse polarity protection | For all electrical connections |
| Electrical connection 1, connection type | Plug |
| Electrical connection 1, connector system | Plug pattern L1J |
| Electrical connection 1, number of connections/cores | 4 |
| Type of mounting | With accessories |
| Mounting position | Any |
| Pneumatic connection | For tubing O.D. 4 mm |
| Pneumatic connection, outlet direction | Straight |
| Product weight | 60 g |
| Material housing | Reinforced PA |
| Material in contact with the medium | NBR, High-alloy stainless steel, Reinforced PA, Wrought aluminium alloy, anodised, Epoxy resin, Silicon, Silicon nitride |
| Display type | Illuminated LCD, multi-colour |
| Displayable units | g, g/min, l, l/h, l/min, scft, scft/h |
| Setting options | IO-Link, Teach-in, Via display and buttons |
| Protection against tampering | IO-Link, PIN code |
| Degree of protection | IP40 |
| Pressure drop | below 5 mbar |
| Protection class | III |
| Corrosion resistance class CRC | 2 - Moderate corrosion stress |
| Weight | 0.11 kg |
| Manufacturer | Festo |
| Hersteller-Nr | SFAH-0.1U-Q4S-PNLK-PNVBA-L1 |
| EAN | 4052568295431 |
| Zolltarifnummer | 90268020 |
| GPSR Herstellerdaten | Festo Vertrieb GmbH&Co. KG, Festo Campus 1, DE-73734 Esslingen, festo.com |
| Artikelzustand | New |
| Artikel-Authentizität | Original product |
| Material | Polyamide (PA) |
| Medium | Compressed air, neutral gases |
| Medientemperatur [°C] | 0 bis 50 |
| Operating conditions | ISO 8573-1 |
| Operating voltage | 22-26 V |
| Series | SFAH |
| Betriebsdruck max [bar] | 10 |
| Protection rating | IP40 |
| Temperaturbereich | 0-50 °C |
| Temperature (max.) | 50 |
Downloads
Accessories
Connecting cable M8x1, 3-pin, 3-wire, socket, angled, open end 2.5 m SIM-M8-3WD-2,5-PSL-PU - Festo 159424
Item FES-159424Flow sensor 0.002 to 0.1 l/min for compressed air 4 mm tubing IO-Link SFAH-0.1U-Q4S-PNLK-PNVBA-M8 - Festo 8058462
Item FES-8058462Flow sensor 0.01 to 0.5 l/min for compressed air 4 mm tubing IO-Link SFAH-0.5U-Q4S-PNLK-PNVBA-L1 - Festo 8058463
Item FES-8058463Flow sensor 0.01 to 0.5 l/min for compressed air 4 mm tubing IO-Link SFAH-0.5U-Q4S-PNLK-PNVBA-M8 - Festo 8058464
Item FES-8058464Flow sensor 0.02 to 1 l/min for compressed air 4 mm tubing IO-Link SFAH-1U-Q4S-PNLK-PNVBA-L1 - Festo 8058465
Item FES-8058465Flow sensor 0.02 to 1 l/min for compressed air 4 mm tubing IO-Link SFAH-1U-Q4S-PNLK-PNVBA-M8 - Festo 8058466
Item FES-8058466Flow sensor 0.1 to 5 l/min for compressed air 6 mm tubing IO-Link SFAH-5U-Q6S-PNLK-PNVBA-L1 - Festo 8058467
Item FES-8058467Questions about this item
Any other question?
Send us the item number and your question. We clarify technical details directly with the manufacturer and usually reply on the next working day.