Images are examples, some edited with AI. The technical data are authoritative. AI notice
5/3-way solenoid valve, pilot-operated, pressure centre, G 1/2, 1350 l/min, 230 V AC - E.MC
Pilot-operated 5/3-way solenoid valve from the E.MC RV series for 230 V AC, G 1/2 ports, 1350 l/min. With its pressure centre it keeps both cylinder chambers pressurised at rest. IP65 protection and a response time below 0.05 s.
- Specialist dealer since 2009
- Invoice payment for regular customers
- Worldwide shipping
- Technical questions clarified with the manufacturer
Description
A 5/3-way valve drives a double-acting cylinder in both directions and decides what happens in the third position. The pilot-operated valve from the E.MC RV series switches with two 230 V AC coils and passes up to 1350 l/min at its G 1/2 port. With neither coil energised, the spool sits in the centre position. Both working ports are then supplied with pressure. With a through rod the forces balance out, with a single rod the area difference pushes the piston slowly outwards.
Advantages
- Operating pressure of 1.5 to 8 bar with a 12 bar test pressure, and the air does not need to be lubricated.
- Flow rate of 1350 l/min at 6.2 mm nominal diameter and 30 mm² effective area (Cv 1.67), enough air for brisk strokes without the valve throttling them.
- IP65 protection to DIN 40050 and insulation class F, each coil draws 4 VA.
- Response time below 0.05 s and up to 3 cycles per second for cycled sequences.
Applications
- Gentle follow-up stroke of a single-rod cylinder driven by the area difference.
- Large-volume cylinders and rotary actuators that need 1350 l/min at a G 1/2 port.
- Simple controls that run directly on 230 V AC without a power supply.
Accessories and spare parts
A matching 230 V AC replacement coil, type T1, is available separately. For wiring with plug-in connectors, E.MC lists connection cables in 0.3, 0.6 and 1 m lengths.
Technical data
| Feature | Value |
|---|---|
| Switching function | 5/3-way, pressure centre |
| Actuation | solenoid, pilot-operated, both sides |
| Coil voltage | 230 V AC |
| Voltage tolerance | -15 % to +10 % |
| Power consumption per coil | 4 VA |
| Coil | type T1, connector size 1 |
| Protection class | IP65 (DIN 40050) |
| Insulation class | F |
| Response time | below 0.05 s |
| Max. switching frequency | 3 cycles/s |
| Working ports (3x) | G 1/2 |
| Exhaust ports (2x) | G 1/2 |
| Nominal diameter | 6.2 mm |
| Flow rate | 1350 l/min |
| Effective area | 30 mm² (Cv 1.67) |
| Operating pressure | 1.5 to 8 bar (0.15 to 0.8 MPa) |
| Test pressure | 12 bar |
| Medium | compressed air, filtered to 40 µm, lubricated or non-lubricated |
| Temperature | -20 to 70 °C, non-freezing |
| Materials | valve body and spool aluminium alloy, HNBR O-rings, POM piston, copper coil, pilot unit engineering plastic |
| Service life | min. 40 million cycles |
| Weight | 750 g |
| Scope of delivery | valve, with coils and plug connectors supplied loose |
| Dimension drawing | in the E.MC datasheet (PDF) |
| Manufacturer | E.MC |
| Hersteller-Nr | RV 5342-15P-230V |
| EAN | 4050571716714 |
| Zolltarifnummer | 84812090 |
| GPSR Herstellerdaten | A1-ESD equipment GmbH. Keldersstr. 15, DE-42697 Solingen, www.esd.equipment |
| Artikelzustand | New |
| Artikel-Authentizität | Original product |
| Nominal size DN [mm] | 6,2 |
| Function | Mittelstellung belüftet |
| Flow rate [l/min] | 1350 |
| Gewinde Abluft (2x) | G 1/2 |
| Leistungsaufnahme (AC) [VA] | 4 |
| Operating voltage | 230 V AC |
| Temperaturbereich | -20-70 °C |
Downloads
Accessories
Questions about this item
Any other question?
Send us the item number and your question. We clarify technical details directly with the manufacturer and usually reply on the next working day.