This 3/2-way solenoid valve controls the air path in a compressed air system. The switching function is Impulse valve. The connection is G 1/8". The operating pressure is stated as 1.5 to 8 bar. The materials are body and spool aluminium, seals NBR, pilot polyamide.
Advantages
- Temperature range of -5 to +60 °C, which covers use in the machine room as well as outdoors.
- Service life min. 40 million switching cycles, enough for continuous multi-shift operation.
- Connection G 1/8" and exhaust G 1/8", so the piping follows the existing line network.
- Control voltage tolerance plus/minus 10 percent, which makes short supply dips uncritical.
- Media oiled and non-oiled, filtered compressed air, so no separate treatment is needed.
Technical data
| Feature | Value |
|---|
| Function | Impulse valve |
|---|
| Control voltage | 12 V DC |
|---|
| Thread G1 (2x) | G 1/8" |
|---|
| Exhaust thread G1 (1x) | G 1/8" |
|---|
| Nominal diameter [mm] | 3.9 |
|---|
| Flow rate [l/min] | 500 |
|---|
| Power consumption (DC) [W] | 2.8 |
|---|
| Dimensions [mm] | A 132.2, B 27, C 18, D 7.5, E 55.6, F 21, H1 3.2, H2 3.3, J 13, K 56.6, L 19, M 58.1, N 16, O 67.1, P 1.5, U 55.2, V 33.9, W 2 |
|---|
| Material body and spool | aluminium |
|---|
| Material seals | NBR |
|---|
| Material pilot | polyamide |
|---|
| Temperature range | -5 to +60 °C |
|---|
| Operating pressure | 1.5 to 8 bar |
|---|
| Media | oiled and non-oiled, filtered compressed air |
|---|
| Switching time (at 5 bar) | below 50 ms, max. 5 switching cycles / sec. (5/3-way: max. 3 switching cycles / sec.) |
|---|
| Control voltages | Standard: 24 V DC, 230 V AC, other voltages on request |
|---|
| Voltage tolerance | plus/minus 10 percent |
|---|
| Protection class | IP 65 |
|---|
| Service life | min. 40 million switching cycles |
|---|
Applications
- Sequencing of pneumatic axes with connection G 1/8" in handling equipment.
- Installation in control cabinets with a supply of 12 V DC.
- Control of pneumatic flaps, gates and diverters in conveying equipment.
- Cycled feeding and clamping units in fixture building.