This 3/2-way solenoid valve switches the air path electrically and needs no manual action at the machine. The connection is G 1/4" and control is by 24 V DC. The switching function is Impulse valve. The operating pressure is stated as 1.5 to 8 bar. The materials are body and spool aluminium, seals NBR, pilot polyamide.
Advantages
- Operating pressure of 1.5 to 8 bar, which fixes the permissible working range.
- Materials body and spool aluminium, seals NBR, pilot polyamide, matched to the intended service.
- Protection class IP 65 at the solenoid coil, suitable for dusty surroundings.
- Temperature range of -5 to +60 °C, which covers use in the machine room as well as outdoors.
- Service life min. 40 million switching cycles, enough for continuous multi-shift operation.
Technical data
| Feature | Value |
|---|
| Function | Impulse valve |
|---|
| Control voltage | 24 V DC |
|---|
| Thread G1 (2x) | G 1/4" |
|---|
| Exhaust thread G1 (1x) | G 1/4" |
|---|
| Nominal diameter [mm] | 5.6 |
|---|
| Flow rate [l/min] | 1150 |
|---|
| Power consumption (DC) [W] | 3 |
|---|
| Dimensions [mm] | A 175.4, B 40, C 27, D 10.5, E 72.7, F 30, H1 4.3, H2 4.3, J 20, K 70.2, L 35, M 75.7, N 24, O 87.7, P 0, U 70, V 40.5, W 0 |
|---|
| Material body and spool | aluminium |
|---|
| Material seals | NBR |
|---|
| Material pilot | polyamide |
|---|
| Temperature range | -5 to +60 °C |
|---|
| Operating pressure | 1.5 to 8 bar |
|---|
| Media | oiled and non-oiled, filtered compressed air |
|---|
| Switching time (at 5 bar) | below 50 ms, max. 5 switching cycles / sec. (5/3-way: max. 3 switching cycles / sec.) |
|---|
| Control voltages | Standard: 24 V DC, 230 V AC, other voltages on request |
|---|
| Voltage tolerance | plus/minus 10 percent |
|---|
| Protection class | IP 65 |
|---|
| Service life | min. 40 million switching cycles |
|---|
Applications
- Sequencing of pneumatic axes with connection G 1/4" in handling equipment.
- Installation in control cabinets with a supply of 24 V DC.
- Control of pneumatic flaps, gates and diverters in conveying equipment.
- Cycled feeding and clamping units in fixture building.