Service unit 3-part »Standard«, Metal container - Riegler K2217
-
This Item:
As low as €125.87
-
Shut-off valve+FR+lub »SYNTESI«, s.2, G 3/4, 5µm, 0…12 bar, RMSA - Riegler 145010
€174.03
-
Service unit 2-part »FUTURA«, Metal, Size 2, G 3/8, 0.2-4, Semi - Riegler 139558
€188.67
Service unit 3-part »Standard«, Metal container. This range covers 8 variants from 125.87 EUR. Select the version you need above.
Available variants
| Thread | G 1/4, G 3/8, G 1/2, G 3/4, G 1, G 1 1/4, G 1 1/2 |
|---|---|
| Nominal size DN [mm] | 6, 15, 20, 25, 35 |
| Size BG | 1, 3, 4, 2 |
Shared technical data
| Bowl | Metallbehälter |
|---|---|
| Sealant | NBR |
| Flow rate measurement | bei P1 = 8 bar, P2 = 6 bar und Druckabfall Δp = 1 bar |
| Housing | Zink-Druckguss / Aluminium, silber lackiert |
| Condensate drain | manuell |
| Pressure gauge display max. | 25 bar |
| Pressure gauge display min. | 0 bar |
| Medium | Druckluft, neutrale Gase |
| Max. medium temperature | 60 °C |
| Min. medium temperature | -10 °C |
| Max. control range | 16 bar |
| Min. control range | 0,5 bar |
| Series | Standard |
| Sight dome | Zink-Glas-NBR |
| Max. ambient temperature | 60 °C |
| Min. ambient temperature | -10 °C |
| Country of origin | DE |
| Customs tariff number | 84811005 |
About Service systems multi-part
Multi-part air preparation units combine filter, regulator and lubricator in one assembly and condition the compressed air right before the machine. The range filters from 5 to 40 µm, regulates to end pressures between 1 and 16 bar and handles flow rates from 300 to 13500 l/min.
What matters when choosing
- Flow rate from 300 to 13500 l/min: size it to the machine's real air demand, otherwise pressure collapses on load peaks.
- Filter rating between 5 and 40 µm: coarser elements last longer, finer ones give valves and cylinders better protection.
- Control range: lower limits fall between 0 and 2.5 bar, upper limits between 1 and 16 bar. Keep the working pressure away from the edge of the range you choose.
- Condensate drain, manual, semi-automatic (RMSA) or fully automatic (RA, also the version closed when depressurised): automatic drains pay off where access is poor or condensate loads are high.
- Port size from G 1/8 to G 1 1/2 and body size BG: both have to suit line size and flow. Maximum inlet pressure runs between 10 and 25 bar depending on version.
Typical applications
- Central conditioning at the air inlet of a machine or cell
- Supply for air tools at assembly workstations
- Lubrication of impact tools and air motors through the lubricator stage
- Preparing control air for valve manifolds and pneumatic controls
- Separate pressure levels for individual sections of a production line
The intended media are compressed air and neutral gases, seals are NBR. Bodies range from technopolymer and PA66 GF60 through zinc die-cast to aluminium die-cast, and the 801 items are spread across the FUTURA, SYNTESI, multifix, variobloc, GA, ONE and Standard series including their mini versions.
| Manufacturer | Riegler |
|---|---|
| GPSR Herstellerdaten | Riegler & Co. KG, Schützenstraße 27, DE-72574 Bad Urach, www.riegler.de |
| Artikelzustand | New |
| Artikel-Authentizität | Original product |