Images are examples, some edited with AI. The technical data are authoritative. AI notice
Herion 3/2-way solenoid valve G1/2, normally closed, without coil, 2.5 to 8 bar - Norgren 9713555000000000
The 9713555000000000 is a 97105 series inline solenoid valve from the Norgren Herion range, built as a 3/2-way valve (normally closed) with a G1/2 port. In the pressure range of 2.5 to 8 bar the 9713555000000000 reaches a flow rate of 2600 l/min. The 9713555000000000 is supplied without a solenoid coil, which is selected separately to suit the control voltage.
- Specialist dealer since 2009
- Invoice payment for regular customers
- Worldwide shipping
- Technical questions clarified with the manufacturer
Description
The 9713555000000000 is a 97105 series inline solenoid valve from the Norgren Herion range, built as a 3/2-way valve (normally closed) with a G1/2 port. In the pressure range of 2.5 to 8 bar the 9713555000000000 reaches a flow rate of 2600 l/min. The 9713555000000000 is supplied without a solenoid coil, which is selected separately to suit the control voltage. The 9713555000000000 is actuated by a solenoid pilot with spring return. The body of the 9713555000000000 is made of anodised aluminium, seals are NBR. For safety applications Norgren rates the 9713555000000000 up to SIL 3. The permissible operating temperature of the 9713555000000000 ranges from -40 to 65 °C.
Benefits and key values
- Flow rate 2600 l/min
- Operating pressure 2.5 to 8 bar
- B10 value 2,500,000 cycles
- Use from -40 to 65 °C
- Safety integrity up to SIL 3
- Suited for outdoor use under critical environmental conditions
- Crossover-free switching
- Add-on manual override
Applications
The 9713555000000000 is used to control process valves, rotary actuators and cylinders in process and plant engineering. The 9713555000000000 is ordered directly under its Norgren number, so the part matches the existing version without cross-referencing.
Technical data
| Manufacturer | Norgren (Herion) |
|---|---|
| Order number | 9713555000000000 |
| Product type | 97105 series inline solenoid valve |
| Valve function | 3/2 |
| Switching position | normally closed |
| Actuation | solenoid pilot with spring return |
| Port | G1/2 |
| Operating pressure | 2.5 to 8 bar |
| Flow rate | 2600 l/min |
| Medium | compressed air |
| Operating temperature | -40 to 65 °C |
| Body material | anodised aluminium |
| Valve technology | soft-seal spool |
| Spool and sleeve | stainless steel |
| Seal material | NBR (nitrile rubber) |
| Solenoid coil | not included |
| B10 value | 2,500,000 cycles |
| Safety integrity | SIL 3 |
| Weight | 0.65 kg |
| RoHS | compliant |
| REACH | no SVHC substances present |
| WEEE | not subject to WEEE |
| Customs tariff number | 84818059 |
| ECLASS | 51030105 |
| Hersteller-Nr | 9713555000000000 |
| Zolltarifnummer | 84818059 |
| GPSR Herstellerdaten | Norgren GmbH, Bruckstraße 93, DE-46519 Alpen, www.norgren.com |
| Artikelzustand | New |
| Artikel-Authentizität | Original product |
| Ausführung | ohne Magnetspule |
| Bauform | Magnetventil der Baureihe 97105 für Rohreinbau |
| Housing material | Aluminium, anodised |
| Function | 3/2 closed monostable |
| Flow rate [l/min] | 2600 |
| Actuation type | Electrical |
| Betriebsdruck max [bar] | 8 |
| Pneumatic connection | G1/2 |
| Temperature (max.) | 65 |
Downloads
Questions about this item
Any other question?
Send us the item number and your question. We clarify technical details directly with the manufacturer and usually reply on the next working day.