Images are examples, some edited with AI. The technical data are authoritative. AI notice

5/2-way valve, inline, 1/2 NPT, without solenoid, series 97105 - Norgren 9710265000000000

Norgren ✓ Original product Brand new

The Norgren 5/2-way valve 9710265000000000 from the 97105 series controls actuators, its key data are port 1/2 NPT, operating pressure 2.5 to 8 bar and flow 2600 l/min. The 9710265000000000 is supplied without solenoid, the coil is selected separately to match the control voltage. The body of the 9710265000000000 is made of anodised aluminium, the seals of HNBR.

Net
€1,120.96
excl. VAT
Item NRG-9710265000000000
Manufacturer no. 9710265000000000
Question about this item
  • Specialist dealer since 2009
  • Invoice payment for regular customers
  • Worldwide shipping
  • Technical questions clarified with the manufacturer

Description

With port 1/2 NPT, operating pressure 2.5 to 8 bar and flow 2600 l/min the 5/2-way valve 9710265000000000 by IMI Herion is designed for controlling pneumatic actuators.

Benefits

  • Flow: the 9710265000000000 valve reaches 2600 l/min, which sets the stroking time of the actuator.
  • Approval: Norgren states a TÜV type examination to DIN EN 161, DIN 3394 and IEC 61508 for the 9710265000000000 valve.
  • Safety: the 9710265000000000 is suitable for multi-channel safety systems up to SIL 3.
  • Service life: Norgren states a B10 value of 2,500,000 switching cycles for the 9710265000000000 valve.
  • Material: the 9710265000000000 has an anodised aluminium body.
  • Temperature range: the 9710265000000000 works at operating temperatures from -25 to 80 °C.

Applications

The 9710265000000000 is installed in the pipework as an inline valve and controls cylinders or rotary actuators remotely.

Technical data

ManufacturerNorgren
Manufacturer part number9710265000000000
BrandIMI Herion
Series97105
Product type5/2-way valve
Valve function5/2-way
Actuationsolenoid pilot / spring return
Valve designsoft-seal spool
Mountinginline
Port1/2 NPT
Flow2600 l/min
Operating pressure2.5 to 8 bar
Mediumcompressed air
Operating temperature-25 to 80 °C
Bodyanodised aluminium
Spool and sleevestainless steel
SealsHNBR (hydrogenated nitrile rubber)
Solenoidnot included, to be ordered separately
B10 value2,500,000 cycles
RoHScompliant
Environmentoutdoor use in critical environmental conditions
Switchingcrossover-free
Manual overrideadd-on
TÜV approvaltype examination to DIN EN 161, DIN 3394 and IEC 61508
Solenoid protection typesEx e mb, Ex d mb, Ex mb, Ex ia for zones 1 and 2 (gas), 21 and 22 (dust)
Safety systemsmulti-channel up to SIL 3
International approvalsIEC Ex, FM, CSA, others on request
Customs tariff number84818059
Weight0.1 kg
Hersteller-Nr9710265000000000
Zolltarifnummer84818059
GPSR HerstellerdatenNorgren GmbH, Bruckstraße 93, DE-46519 Alpen, www.norgren.com
ArtikelzustandNew
Artikel-AuthentizitätOriginal product
Seal materialHNBR
Housing materialAluminium, anodised
Function5/2
Flow rate [l/min]2600
Actuation typeElectrical
Betriebsdruck max [bar]8
Pneumatic connectionNPT 1/2
Temperature (max.)80