End plate VMPAL-EPL-AP - Festo 8087171
- Specialist dealer since 2009
- Invoice payment for regular customers
- Worldwide shipping
- Technical questions clarified with the manufacturer
Technical data
| Position of connection | On top |
|---|---|
| Reverse polarity protection | Yes |
| Diagnostics via LED | Diagnostics per module, Load power supply |
| Diagnostics per internal communication | Electronics/sensors overvoltage, Electronics/sensors undervoltage |
| Max. number of valve positions | 32 |
| Valve terminal structure | Valve sizes can be mixed |
| Max. number of valve coils | 32 |
| Dimensions (W x L x H) | 43.1 mm x 107.5 mm x 50.2 mm |
| Fuse protection (short circuit) | Internal electronic fuse per channel |
| Intrinsic current consumption at nominal operating voltage for electronics/sensors | Typically 30 mA |
| Intrinsic current consumption at nominal operating voltage load | Typically 15 mA |
| Max. power supply | 2 x 4 A (external fuse required) |
| Nominal DC operating voltage, electronics/sensors | 24 V |
| Nominal operating voltage DC of load | 24 V |
| Power failure bridging | 10 ms |
| Electrical isolation of outputs between channel - internal communication | Yes |
| Permissible voltage fluctuations for electronics/sensors | ±25% |
| Permissible voltage fluctuation of load | ±10% |
| Power supply, function | Incoming electronics/sensors and load |
| Power supply, connection type | Plug |
| power supply, connection system | M8x1, A-coded to EN 61076-2-104 |
| Power supply, number of pins/wires | 4 |
| Power transmission, function | Outgoing electronics/sensors and load |
| Power transmission, connection type | Socket |
| Power transmission, connection technology | M8x1, A-coded to EN 61076-2-104 |
| Power transmission, number of pins/wires | 4 |
| Approval | RCM |
| KC mark | KC-EMV |
| CE mark (see declaration of conformity) | To EU EMC Directive, In accordance with EU RoHS Directive |
| UKCA marking (see declaration of conformity) | To UK instructions for EMC, To UK RoHS instructions |
| Corrosion resistance class CRC | 3 - high corrosion stress |
| LABS (PWIS) conformity | VDMA24364-B1/B2-L |
| Storage temperature | -40 ... 70 °C |
| Relative air humidity | 5 - 95%, Non-condensing |
| Protection against direct and indirect contact | PELV, Safety extra-low voltage |
| Degree of protection | IP65, IP67 |
| Note on degree of protection | In mounted state, Unused connections sealed |
| Ambient temperature | -5 ... 50 °C |
| Nominal altitude of use | <= 2000 m NHN |
| Max. tightening torque | 1.7 Nm |
| Product weight | 194 g |
| Max. cable length | 50 m system communication |
| Communication interface, function | System communication XF10 IN / XF20 OUT |
| Communication interface, connection type | 2x socket |
| Communication interface, connection technology | M8x1, D-coded according to EN 61076-2-114 |
| Communication interface, number of pins/cores | 4 |
| Communication interface, protocol | AP-COM |
| Communication interface, screened | Yes |
| Type of mounting | Tie rod |
| Note on materials | RoHS compliant |
| Material housing | Painted die cast aluminium, Reinforced PA |
| Material threaded sleeve | Nickel-plated brass |
| Weight | 0.21 kg |
| Manufacturer | Festo |
| Hersteller-Nr | VMPAL-EPL-AP |
| EAN | 4052568459352 |
| Zolltarifnummer | 84819000 |
| GPSR Herstellerdaten | Festo Vertrieb GmbH&Co. KG, Festo Campus 1, DE-73734 Esslingen, festo.com |
| Artikelzustand | New |
| Artikel-Authentizität | Original product |
Downloads
Questions about this item
Any other question?
Send us the item number and your question. We clarify technical details directly with the manufacturer and usually reply on the next working day.