Images are examples, some edited with AI. The technical data are authoritative. AI notice
Set of wearing parts, SV, NC/NO, MS, DN13, NBR, pilot ope., short - Riegler 129917
Set of wearing parts, SV, NC/NO, MS, DN13, NBR, pilot ope., short
- Specialist dealer since 2009
- Invoice payment for regular customers
- Worldwide shipping
- Technical questions clarified with the manufacturer
Description
Set of wearing parts Solenoid valve, NC/NO, MS, DN13, NBR, pilot-operated, short
Standards and origin
- Customs tariff number: 84819000
- Country of origin: DE
About Solenoid valves
Solenoid valves switch a media flow electrically, with no manual intervention at the line. The range covers nominal sizes from DN 1 to DN 66 and operating pressures up to 50 bar, with ports from G 1/8 to G 2. Some versions work from -1 bar upwards, which makes them suitable for vacuum duty.
What matters when choosing
- Function: normally closed (NC), normally open (NO) or any flow direction (BEL). What matters is the state the plant should assume when power is lost.
- Voltage: 12 V DC, 24 V DC, 24 V AC, 110 V AC and 230 V AC, plus 24 V AC/DC and 230 V AC/DC versions. Follow whatever the existing control system supplies.
- Sealing material NBR, FKM, FPM, EPDM, PTFE or FFKM: match the elastomer to the medium and to the media temperature, which runs between -30 and 160 °C depending on version.
- Body material: brass, aluminium, polyamide, glass-fibre reinforced polyamide, polypropylene or stainless steel 1.4301, 1.4401 and 1.4581. Stainless steel is the choice for corrosive media and demanding wash-down regimes.
- Nominal size DN 1 to 66 mm and operating pressure: upper limits run from 1 to 50 bar, and nominal size sets the achievable flow.
Typical applications
- Shutting off and releasing compressed air in machines and plant
- Cleaning fabric filters in dust collection systems using pulse diaphragm valves
- Switching duties in cooling and heating water circuits
- Dosing and filling stations handling thin, neutral media
- Vacuum applications with operating pressures from -1 bar
Threads are made to DIN EN ISO 228-1 or ISO 7-1. Protection class IP 65 or IP 67 is reached with the connector socket correctly fitted.
Technical data
| Sealant | NBR |
|---|---|
| Min. ambient temperature | -10 °C |
| Max. ambient temperature | 50 °C |
| Min. medium temperature | -20 °C |
| Max. medium temperature | 85 °C |
| Function | for deenergised open (NO) and deenergised closed (NC) |
| DN | 13 mm |
| Manufacturer | Riegler |
| Hersteller-Nr | VSTMV.A/B.MS.N.RV.13.K |
| EAN | 4047322744263 |
| Zolltarifnummer | 84819000 |
| GPSR Herstellerdaten | Riegler & Co. KG, Schützenstraße 27, DE-72574 Bad Urach, www.riegler.de |
| Artikelzustand | New |
| Artikel-Authentizität | Original product |
| Country of Manufacture | Germany |
| Nominal size DN [mm] | 13 |
| Seal material | NBR |
| Function | for normally open (NO) and normally closed (NC) |
| Norm | DIN EN ISO 228-1 |
Downloads
Questions about this item
Any other question?
Send us the item number and your question. We clarify technical details directly with the manufacturer and usually reply on the next working day. Ask a question