Valve terminal 1 Series, 4x 5/2-way single solenoid, M7 side-ported, DeviceNet - E.MC
Decentralised DeviceNet valve terminal: 4x spring-return 5/2-way valve and 8 M7 outlets. The bus node reports short circuit, wire break and undervoltage back to the controller.
- Specialist dealer since 2009
- Invoice payment for regular customers
- Worldwide shipping
- Technical questions clarified with the manufacturer
Description
This terminal puts 4 valves straight onto a DeviceNet network, with no output cards and no multipole cable to the cabinet. The bus node sits on the terminal, the 8 M7 outlets are on the side of the sub-base.
Advantages
- Straight onto DeviceNet: bus connection M12 plug and M12 socket, 5-pin, A-coded, power via M12, no output card needed in the controller.
- Swap valves without touching the tubing: the M7 outlets are in the sub-base, the valves are changed from above.
- Narrow build: 11.5 mm pitch per valve station, response time 15 ms or less at 5 bar.
- Reconfigurable: any station can later take a valve with one or two coils, including 5/3-way or 2x 3/2-way functions.
- Long service life: at least 40 million cycles, aluminium body and spool, NBR seals.
Applications
- Decentralised valve terminals right at the machine, integrated into an existing DeviceNet network
- Installations with frequent valve changes, where the tubing should stay connected during a swap
- Pick-and-place and handling units with small-bore cylinders, short-stroke cylinders and grippers on 4 to 6 mm tubing
Accessories
E.MC supplies M12 power cables, matching bus cables and blanking plates for unused stations.
Technical data
| Design | valve terminal, valves on manifold base, integrated wiring |
|---|---|
| Series | E.MC ESV, 1 Series with fieldbus module |
| Valve stations | 4 |
| Fitted valves | 5/2-way, single solenoid, air and spring return |
| Working ports | 8x M7, side-ported on the sub-base |
| Supply | central, G 1/8 |
| Valve pitch | 11.5 mm |
| Control | fieldbus DeviceNet |
| Bus connection | M12 plug and M12 socket, 5-pin, A-coded |
| Bus module power | M12, 5-pin, A-coded |
| Bus module supply voltage | 24 V DC (21.6 to 26.4 V) |
| Bus module current draw | below 50 mA |
| Operating pressure | 1.5 to 8 bar (5/3-way and 2x 3/2-way: 2 to 8 bar) |
| Proof pressure | 12 bar |
| Medium | clean compressed air, filtered to 40 µm, no lubrication required |
| Ambient temperature | -10 to +60 °C (bus module) |
| Valve voltage | 24 V DC ±10 % |
| Power consumption | 0.8 W per solenoid |
| Insulation class | F |
| Response time | 15 ms or less at 5 bar |
| Max. switching frequency | 5 Hz (5/3-way: 3 Hz) |
| Effective area per station | 7 mm² (Cv 0.39) |
| Flow per station | approx. 330 l/min |
| Materials | body and spool aluminium, seals NBR, pilot plastic |
| Service life | at least 40 million cycles |
| Indicator | LED per solenoid |
| Protection class | IP 40 |
| Certification | UL |
| Mounting | DIN rail or screws, DIN adapter included |
| Overall length | 118.5 mm |
| Dimension drawing | in the E.MC datasheet (PDF) |
| Manufacturer | E.MC |
| Hersteller-Nr | S1V-M7-4M-DN |
| EAN | 4070497020436 |
| Zolltarifnummer | 84812090 |
| GPSR Herstellerdaten | A1-ESD equipment GmbH. Keldersstr. 15, DE-42697 Solingen, www.esd.equipment |
| Artikelzustand | New |
| Artikel-Authentizität | Original product |
| Anzahl Stationen [Stk] | 4 |
| Temperaturbereich | -10-60 °C |
Downloads