Signal module EB 80, 4x M8 for temperature measurement - Riegler 150930
-
This Item:
€451.48
-
Base plate EB 80, 3-fold, full-flow ports, 6 controls, Ø 8 mm - Riegler 151657
€84.52
-
Air supply EB 80, Ø 12 mm, silenced relief, internal pilot air - Riegler 151068
€30.16
Signal module for valve island EB 80, 4x M8 analogue inputs for temperature measurement The EB 80 system supports a wide range of input/output signal modules that can be easily added to fieldbus-connected or additional systems. Installation is simple: just remove the aluminum end plate on the left side of the "Electrical connection with fieldbus - E" module, insert the signal modules with tie rods, and reattach the plate. Each signal module has two parts, ensuring flexibility and easy maintenance: Lower section: universal transmission electronics. Upper section: type-specific and easily replaceable, either with an identical or different module, without removing anything else from the system. The special EB 80 Wireless Module supports both Bluetooth® and Wi-Fi, enabling access to data via the EB 80 I4.0 diagnostics functions. It enhances traditional servicing with advanced analytics for safe, reliable, and long-term operation. Using the dedicated "Metal Work EB80Up" app, the module connects to mobile devices via Bluetooth®. Additionally, it supports Ethernet communication through the MQTT protocol, allowing full network configuration.
Technical data
| Sealant | NBR |
|---|---|
| Version | 4 x M8 analogue inputs for temperature measurement |
| Supply voltage range | 12 -10 % to 24 +25 % V DC |
| Operating voltage min. | 10.8 V DC |
| Operating voltage max. | 30 V DC |
| Max. admissible voltage | 30 V DC* |
| Electrical connection | 4x M8 female connector, 4-pin |
| Repeatability | ±0.03 % (ambient temperature 25 °C) |
| Min. ambient temperature | -10 °C |
| Max. ambient temperature | 50 °C |
| Housing | technopolymer |
| Module type | S |
| Module description | signal module |
| Sensors supply voltage | corresponding to the supply voltage |
| Protection | not necessary, 30V supply voltage generated by module itself |
| Diagnostics | one LED for each input and reporting to the Master |
| Digital convert resolution | 15 bit + prefix |
| Sensor type (RTD) platinum (-200 to 850 °C) | Pt100, Pt200, Pt500, Pt1000 (TK = 0.00385 and TK = 0.00391) |
| Sensor type (RTD) nickel (-60 to 180 °C) | Ni100, Ni120, Ni500, Ni1000 (TK = 0.00618) |
| Connections type (RTD) | 2, 3 or 4 wire |
| Type of thermocouple (TC) | J, E, T, K, N, S, B, R |
| Cold junction compensation for thermocouples, internal | with internal electronic sensor included |
| Cold junction compensation for thermocouples, external | PT1000 sensor (connection on M8 thermocouple plug) |
| Max. error compared to ambient temperature | ±0.5 % (TC) | ±0.06 % (RTD) |
| Max. basic error (ambient 25 °C) | TC ±0.4% | RTD 4 wire ±0.6°C (res. 0.1) | ±0.2°C (res. 0.01) |
| Address employment | 2 bytes for each input - 8 bytes per module |
| Software linearization | RTD: piecewise linear approximation. TC: ITS-90 scale. |
| Max. length of shielded cable for the connection | < 30 m |
| Temperature measuring range min. | -200 °C |
| Temperature measuring range max. | 800 °C |
| Cycle time (module) | 240 ms |
| TechnischerHinweis1 | You can find the detailed technical specifications in our data sheets. |
| Protection IP | IP 65 |
| Series | EB 80 |
Standards and origin
- Customs tariff number: 84818099
- Country of origin: IT
About Valve terminals
A valve terminal combines several directional valves, their electrical control and the shared air supply in one assembly. Instead of wiring and tubing every valve separately, one bus cable and one supply line run to the terminal. The valves handle flow rates of 200 to 800 Nl/min at operating pressures up to 10 bar.
What matters when choosing
- Define the function first. Options include 5/2-way monostable, 5/2-way bistable as an impulse valve, 5/3-way with closed centre, and combinations of 3/2-way NC and 3/2-way NO on one slice.
- The connection decides how much wiring is involved. Multipole suits manageable terminals with existing parallel wiring, the version with integrated Profibus DP connects to a fieldbus controller.
- Protection class follows the mounting location. IP 65 for direct mounting on the machine, IP 40 for a protected control cabinet.
- Flow rate from 200 to 800 Nl/min has to match the volume of the connected actuators and the required cycle time.
- Where pressure is controlled rather than only switched, the proportional modules cover a control range of 0.05 to 10 bar at a maximum inlet pressure of 10.5 bar.
Typical applications
- Central valve station for handling and assembly lines with many short cylinder strokes
- Decentralised control mounted on the machine module in IP 65 to shorten tubing runs and switching times
- Packaging and filling lines where grippers, slides and suction cups are coordinated over a fieldbus
- Applications with controlled pressure, for example contact forces set by the proportional modules between 0.05 and 10 bar
- Systems running vacuum and pressure on one terminal using versions with external pilot air
Housings are made from technopolymer, from painted aluminium or from a combination of both, sealed with NBR. The specified medium is filtered, unlubricated compressed air.
| Manufacturer | Riegler |
|---|---|
| Hersteller-Nr | 02282S08 |
| EAN | 4047322814126 |
| Zolltarifnummer | 84818099 |
| GPSR Herstellerdaten | Riegler & Co. KG, Schützenstraße 27, DE-72574 Bad Urach, www.riegler.de |
| Artikelzustand | New |
| Artikel-Authentizität | Original product |
| Country of Manufacture | Italy |
| Ausführung | 4 x M8 Eingänge, analog für Temperaturmessung |
| Material | Technopolymer |
| Seal material | NBR |
| Housing material | Technopolymer |
| Series | EB 80 |
| Protection rating | IP65 |