Diaphragm for impulse diaphragm valve G 3/4 to G 1, AC/DC - Riegler 205210
-
This Item:
€55.22
-
Conversion kit FKM seal for MV 1351/ MV 1361 G/ MV 1367 G/ MV 1357 - Riegler 150941
€58.76
-
2/2-sol.valve,NC,pilot oper.,230-240V,50-60Hz,FKM,G3/8,0.1-20bar - Riegler 102913
€58.38
Diaphragm for impulse diaphragm valve G 3/4 to G 1, type MV 4211-1, MV 4211-1 G, MV 4212-1, MV 4212-1 G
Technical data
| DN | 32 mm |
|---|---|
| Min. medium temperature | -20 °C |
| Max. medium temperature | 140 °C |
| Min. ambient temperature | -20 °C |
| Max. ambient temperature | 85 °C |
Standards and origin
- Customs tariff number: 84819000
- Country of origin: PL
About Solenoid valves
Solenoid valves switch a media flow electrically, with no manual intervention at the line. The range covers nominal sizes from DN 1 to DN 66 and operating pressures up to 50 bar, with ports from G 1/8 to G 2. Some versions work from -1 bar upwards, which makes them suitable for vacuum duty.
What matters when choosing
- Function: normally closed (NC), normally open (NO) or any flow direction (BEL). What matters is the state the plant should assume when power is lost.
- Voltage: 12 V DC, 24 V DC, 24 V AC, 110 V AC and 230 V AC, plus 24 V AC/DC and 230 V AC/DC versions. Follow whatever the existing control system supplies.
- Sealing material NBR, FKM, FPM, EPDM, PTFE or FFKM: match the elastomer to the medium and to the media temperature, which runs between -30 and 160 °C depending on version.
- Body material: brass, aluminium, polyamide, glass-fibre reinforced polyamide, polypropylene or stainless steel 1.4301, 1.4401 and 1.4581. Stainless steel is the choice for corrosive media and demanding wash-down regimes.
- Nominal size DN 1 to 66 mm and operating pressure: upper limits run from 1 to 50 bar, and nominal size sets the achievable flow.
Typical applications
- Shutting off and releasing compressed air in machines and plant
- Cleaning fabric filters in dust collection systems using pulse diaphragm valves
- Switching duties in cooling and heating water circuits
- Dosing and filling stations handling thin, neutral media
- Vacuum applications with operating pressures from -1 bar
Threads are made to DIN EN ISO 228-1 or ISO 7-1. Protection class IP 65 or IP 67 is reached with the connector socket correctly fitted.
| Weight | 0.070000 |
|---|---|
| Manufacturer | Riegler |
| Hersteller-Nr | MIMV |
| EAN | 4047322706551 |
| Zolltarifnummer | 84819000 |
| GPSR Herstellerdaten | Riegler & Co. KG, Schützenstraße 27, DE-72574 Bad Urach, www.riegler.de |
| Artikelzustand | New |
| Artikel-Authentizität | Original product |
| Country of Manufacture | Poland |
| Nominal size DN [mm] | 32 |
| Norm | DIN EN ISO 228-1 |