Electrical fieldbus connection EB 80, POWERLINK

Electrical fieldbus connection EB 80, POWERLINK - Riegler 150962

RIEGLER Original product
Net price (excl. VAT)
€448.46
Item RGL-150962
Manufacturer no. 02282E0PL
Personal expert advice
Brand new Specialist dealer since 2009 Original product Worldwide shipping
Product data
Manufacturer no.02282E0PL
EAN4047322814386
Country of originItaly
Customs tariff number84818099
ConditionNew
Artikel
RGL-150962

Electrical fieldbus connection for valve island EB 80, POWERLINK The Electrical Connection - E subsystem powers EB 80 systems, transmits control signals to solenoid valves, manages I/O communication, and handles diagnostics. Available in multi-pole or fieldbus versions, the valve island operates identically with both (patented), supporting parallel and serial controls. Smart electronics across all modules enable advanced diagnostics. The system supports 12 VDC and 24 VDC operation (patented), tolerates overvoltages up to 31.2 VDC, and functions with a minimum pilot voltage of 10.8 VDC. Multi-pole versions retain full modularity and diagnostics and feature a single-piece metal housing. Fieldbus versions consist of a metal lower body, independent of protocol, and a technopolymer upper section tailored to specific bus protocols (except the IO-Link 64 OUT module, which comes with one-piece metal housing).

Technical data

SealantNBR
Duty cycle100 %
VersionPOWERLINK
Supply voltage range12 -10 % to 24 +30 % V DC
Operating voltage min.10.8 V DC
Operating voltage max.31.2 V DC
Max. admissible voltage32 V DC*
Min. ambient temperature-10 °C
Max. ambient temperature50 °C
Housingtechnopolymer / painted aluminium
Module typeE
Module descriptionelectrical connection with fieldbus
Protectionmodule: overload, polarity inversion | output: overload, SC
DiagnosticsEthernet POWERLINK: LED + SW info, outp.: LED + state bytes
Diagnostic signalsSC, coil fail., UV/OV, mod. com., switch state, dev. config.
Power supply without controlled valves4 W for module "electr. conn.-E" + 0.25 W per "Base-B"
Solenoid pilot power on start-up (speed up)3 W for 15 ms
Max. number of simultaneous solenoid controls on activation38 (greater number possible with "intermediate module - M")
Fieldbus100 Mbit/s, half-duplex, supports auto-negotiation
Bus power supply current absorptionnominal Icc 180 mA at 24 V DC
Maximum number of nodes40 valve bases +16 dig. in-/outp. each +4 an. in-/outp. each
Data bit value0 = non-active, 1 = active
Maximum number of inputs for temperatures16 (count as analogue input)
Connection power supplyM8 male connector, 4-pin
Connection Fieldbus2x M12 female connector, D encoding, internal switch
Addressinghardware via rotary switch
Factory Settingsmodule denomination: EB80series - address number 2
Maximum number of solenoid controls128
Max. admissible current for valve supply, continuous4 A
Max. admissible current for valve supply, instantaneous6 A
Max. admissible current for bus/signal supply, continuous4 A
Max. admissible current for bus/signal supply, instantaneous6 A
Maximum number of digital input signals128
Maximum number of digital output signals128
Maximum number of analogue input signals16
Maximum number of analogue output signals16
Solenoid pilot power after start-up (holding)0.3 W
TechnischerHinweis1You can find the detailed technical specifications in our data sheets.
Power inputmax. 3.15 W
Protection IPIP 65
SeriesEB 80

Standards and origin

  • Customs tariff number: 84818099
  • Country of origin: IT

About Valve terminals

A valve terminal combines several directional valves, their electrical control and the shared air supply in one assembly. Instead of wiring and tubing every valve separately, one bus cable and one supply line run to the terminal. The valves handle flow rates of 200 to 800 Nl/min at operating pressures up to 10 bar.

What matters when choosing

  • Define the function first. Options include 5/2-way monostable, 5/2-way bistable as an impulse valve, 5/3-way with closed centre, and combinations of 3/2-way NC and 3/2-way NO on one slice.
  • The connection decides how much wiring is involved. Multipole suits manageable terminals with existing parallel wiring, the version with integrated Profibus DP connects to a fieldbus controller.
  • Protection class follows the mounting location. IP 65 for direct mounting on the machine, IP 40 for a protected control cabinet.
  • Flow rate from 200 to 800 Nl/min has to match the volume of the connected actuators and the required cycle time.
  • Where pressure is controlled rather than only switched, the proportional modules cover a control range of 0.05 to 10 bar at a maximum inlet pressure of 10.5 bar.

Typical applications

  • Central valve station for handling and assembly lines with many short cylinder strokes
  • Decentralised control mounted on the machine module in IP 65 to shorten tubing runs and switching times
  • Packaging and filling lines where grippers, slides and suction cups are coordinated over a fieldbus
  • Applications with controlled pressure, for example contact forces set by the proportional modules between 0.05 and 10 bar
  • Systems running vacuum and pressure on one terminal using versions with external pilot air

Housings are made from technopolymer, from painted aluminium or from a combination of both, sealed with NBR. The specified medium is filtered, unlubricated compressed air.

More Information
Weight 0.640000
Manufacturer Riegler
Hersteller-Nr 02282E0PL
EAN 4047322814386
Zolltarifnummer 84818099
GPSR Herstellerdaten Riegler & Co. KG, Schützenstraße 27, DE-72574 Bad Urach, www.riegler.de
Artikelzustand New
Artikel-Authentizität Original product
Country of Manufacture Italy
Ausführung POWERLINK
Material Technopolymer / aluminium, painted
Seal material NBR
Housing material Technopolymer / aluminium, painted
Series EB 80
Protection rating IP65