Images are for illustration purposes only and may differ from the actual product. Some images have been generated or edited, in whole or in part, using artificial intelligence systems. The technical specifications in the product description are authoritative.
Electrical fieldbus connection EB 80, IO-Link 64 OUT

Electrical fieldbus connection EB 80, IO-Link 64 OUT - Riegler 150964

RIEGLER Original product
Net price (excl. VAT)
€218.51
Item RGL-150964
Manufacturer no. 02282E0LK
Personal expert advice
Brand new Specialist dealer since 2009 Original product Worldwide shipping
Product data
Manufacturer no.02282E0LK
EAN4047322814409
Country of originItaly
Customs tariff number84818099
ConditionNew
Artikel
RGL-150964

Electrical fieldbus connection for valve island EB 80, IO-Link 64 OUT The Electrical Connection - E subsystem powers EB 80 systems, transmits control signals to solenoid valves, manages I/O communication, and handles diagnostics. Available in multi-pole or fieldbus versions, the valve island operates identically with both (patented), supporting parallel and serial controls. Smart electronics across all modules enable advanced diagnostics. The system supports 12 VDC and 24 VDC operation (patented), tolerates overvoltages up to 31.2 VDC, and functions with a minimum pilot voltage of 10.8 VDC. Multi-pole versions retain full modularity and diagnostics and feature a single-piece metal housing. Fieldbus versions consist of a metal lower body, independent of protocol, and a technopolymer upper section tailored to specific bus protocols (except the IO-Link 64 OUT module, which comes with one-piece metal housing).

Technical data

SealantNBR
Duty cycle100 %
VersionIO-Link 64 OUT
Supply voltage range12 -10 % to 24 +30 % V DC
Operating voltage min.10.8 V DC
Operating voltage max.31.2 V DC
Max. admissible voltage32 V DC*
Min. ambient temperature-10 °C
Max. ambient temperature50 °C
Housingpainted aluminium
Module typeE
Module descriptionelectrical connection with fieldbus
Protectionmodule: overload, polarity inversion | output: overload, SC
DiagnosticsIO-Link: LED + software info, outputs: LED + state bytes
Diagnostic signalsSC, coil fail., UV/OV, mod. com., switch state, dev. config.
Power supply without controlled valves4 W for module "electr. conn.-E" + 0.25 W per "Base-B"
Solenoid pilot power on start-up (speed up)3 W for 15 ms
Max. number of simultaneous solenoid controls on activation38 (greater number possible with "intermediate module - M")
FieldbusIO-Link Version 1.1
Communication speed230.4 Kbps (COM3)
Vendor ID / Device ID1046 (hex 0x0416) / 64 (hex 0x000040)
Process data length1 byte of input / 8 byte of output
IO-Link power supply (L+L - Bus IN Stecker)min. 18 V DC, max. 30 V DC
Bus power supply current absorptionsee IO-Link 64 OUT instruction manual
Maximum number of nodes40 valve bases +16 dig. in-/outp. each +4 an. in-/outp. each
Data bit value0 = non-active, 1 = active
Connection FieldbusM12 male connector, A encoding - port class A - port class B
Maximum number of solenoid controls64
Max. admissible current for valve supply, continuous4 A
Max. admissible current for valve supply, instantaneous6 A
Max. admissible current for bus/signal supply, continuous4 A
Max. admissible current for bus/signal supply, instantaneous6 A
Minimum cycle time2.8 ms
Solenoid pilot power after start-up (holding)0.3 W
TechnischerHinweis1You can find the detailed technical specifications in our data sheets.
Power inputmax. 3.15 W
Protection IPIP 65
SeriesEB 80

Standards and origin

  • Customs tariff number: 84818099
  • Country of origin: IT

About Valve terminals

A valve terminal combines several directional valves, their electrical control and the shared air supply in one assembly. Instead of wiring and tubing every valve separately, one bus cable and one supply line run to the terminal. The valves handle flow rates of 200 to 800 Nl/min at operating pressures up to 10 bar.

What matters when choosing

  • Define the function first. Options include 5/2-way monostable, 5/2-way bistable as an impulse valve, 5/3-way with closed centre, and combinations of 3/2-way NC and 3/2-way NO on one slice.
  • The connection decides how much wiring is involved. Multipole suits manageable terminals with existing parallel wiring, the version with integrated Profibus DP connects to a fieldbus controller.
  • Protection class follows the mounting location. IP 65 for direct mounting on the machine, IP 40 for a protected control cabinet.
  • Flow rate from 200 to 800 Nl/min has to match the volume of the connected actuators and the required cycle time.
  • Where pressure is controlled rather than only switched, the proportional modules cover a control range of 0.05 to 10 bar at a maximum inlet pressure of 10.5 bar.

Typical applications

  • Central valve station for handling and assembly lines with many short cylinder strokes
  • Decentralised control mounted on the machine module in IP 65 to shorten tubing runs and switching times
  • Packaging and filling lines where grippers, slides and suction cups are coordinated over a fieldbus
  • Applications with controlled pressure, for example contact forces set by the proportional modules between 0.05 and 10 bar
  • Systems running vacuum and pressure on one terminal using versions with external pilot air

Housings are made from technopolymer, from painted aluminium or from a combination of both, sealed with NBR. The specified medium is filtered, unlubricated compressed air.

More Information
Weight 0.220000
Manufacturer Riegler
Hersteller-Nr 02282E0LK
EAN 4047322814409
Zolltarifnummer 84818099
GPSR Herstellerdaten Riegler & Co. KG, Schützenstraße 27, DE-72574 Bad Urach, www.riegler.de
Artikelzustand New
Artikel-Authentizität Original product
Country of Manufacture Italy
Ausführung IO-Link 64 OUT
Material Aluminium, painted
Seal material NBR
Housing material Aluminium, painted
Series EB 80
Protection rating IP65